350psi Medrad Lf Nemoto Medtron CT Contrast Media Injectors Syringes Spiral Connecting Tubes

Price Negotiable Compare
Min Order 400 Pieces
Shipping From Guangdong, China
Popularity 358 people viewed
Quantity
+-
 

Shenzhen Boon Medical Supply Co., Ltd.

VIP   Audited Supplier 9 years
Profile Certified by SGS/BV
400101
Radiology Medical Material
Plastic
Ethylene Oxide Sterilization
3years
Adult
With Logo Printing
Boon 1800mm CT Connector Tubing
for CT Injection Procedure
PVC Dehp /Totm/ABS
Medrad /Lf/Ezem/Imaxeon/ Nemoto
Yes
Acceptable
No Valve
13.5kg Per Carton
6% International Luer Lock
One Female/One Male
350psi
Blister Pack
1.85mm
3.25mm
BOON
400PCS Per Box
1500mm/1800mm
Shenzhen
9018310000
Product Description

Description 

Boon Sterile CT coiled tubing used for Enhancing scan imaging, compatible with various different CT injectors. 
helping doctors find lesions more clearly and quickly. Contrast agents and saline are injected through various CT contrast media injectors. Mainly used in the hospital radiology department and medical imaging department.

Boon Angiographic syringes have covered the world's main popular contrast media injectors models, such as Medrad, LF, Medtron, Nemoto, Bracco, SINO, SEACROWN.


Specification
   
 1.5m (1.8m) is for option   400pcs per case
Pressure : 300psi/350psi
 
ItemProduct
Code
Pressure LengthDescription
1400101300psi1800mmCoiled Tube 
2400101A300psi300mmCoiled tube
3400101B300psi1800mmCoiled Tube with one valve
4400101C 
300psi
300mmCoiled Tube with one valve
5400101D300psi1200mmCoiled Tube 
6400101E300psi1000mmCoiled Tube 
7400101F300psi1500mmCoiled Tube 
8400101G300psi1500mmCoiled Tube with one valve
9400101H300psi2000mmCoiled Tube 
10400101J300psi2000mmCoiled Tube with one valve
11400101S300psi2500mmCoiled Tube 
12400101K350psi1800mmCoiled Tube 
13400101L350psi300mmCoiled Tube 
14400101M350psi1800mmCoiled Tube with one valve
15400101P350psi1200mmCoiled Tube 
16400101R350psi1500mmCoiled Tube 
17400101T350psi1500mmCoiled Tube with one valve
18400101Y350psi2500mmCoiled Tube 
                                                                       
Quality Control 

Boon high-pressure syringes strictly implement ISO9001 and ISO13485 quality management systems and are produced in 100,000-level purification workshops. Quality is the life of an enterprise. Boon is always following the quality policy of "Pursuing Product Excellence Ensuring Public Health" 


Package
 
 Reference Data (Sea Freight)
Container20GP40GP40HQ45HQ
Area(M3)25546886
Quantity(Case)260440550700







Instructions for Use
Syringe Filling
1.NOTE: One person should fill and arm the injector. If you must change the injector operator, be certain that the second operator verifies that the syringe is properly filled and that any air is eliminated.
2.Tilt the injector head (or the syringe interface module) up.
3.Advance the plunger to full forward position. 
4.Remove the protective cover from the syringe luer tip and attach a sterile filling device onto the tip of the syringe. Fill straw, or spike.
5.Transfer the contrast media into the syringe by one of following methods:
6.Fill Straw: raise the contrast bottle until the Fill Straw is fully inserted. The end of the Fill Straw should be near the bottom of the contrast bottle.
7.Spike: prepare the bottle or container of contrast and/or saline solution. Push the bottle or bag onto the Filling Device until the seal is punctured.
8.NOTE: Use Fill Straw or equivalent device to reduce the volume and size of air bubbles drawn into the syringe during filling. It is more difficult to remove the air bubbles if you use smaller diameter tubes, such as catheter-over-needle, or a tube longer than 10 in.(25cm.)
9.Aspirate contrast media into the syringe.
10.If the syringe has dot indicators use them to help you detect the presence of contrast media in the syringe. Verify that the Syringe disposable dot indicators are round in the filled portion of the syringe. The rounded shape of the dot indicators varies according to the type of contrast media, but an oblong shape indicates the presence of air. Rounded dot indicators do not indicate the total absence of air bubbles in the syringe tip.
* Refer to the injector operation manual for further instructions.
Expelling Air & Attaching the Connector Tubing
1.After you fill the syringe, you must expel all air from the syringe and then attach the connector tubing. To do so:
2.Remove the filling device and expel air from the syringe. Do not hit the syringe to remove air bubbles. Reverse the plunger 3 to 5 ml, then, if applicable, rock the injector head on the pivot to dislodge the bubbles. Expel the remaining air.
3.If you are using a Y low pressure connector tubing, attach shorter side of the Y to the contrast syringe and the longer side of the Y to the saline syringe. Do not reverse the piston plunger after you have attached the tubing. 
4.Verify that the tubing is not kinked or obstructed.
5.(If your injector does not have a manual knob, proceed to Step 6.) Use the manual knob to advance the syringe plunger to provide 
6.Prime the connector tubing and make certain that the air is expelled. 
7.Verify that all the air has been expelled from the syringe and fluid path. 
8.Attach the connector tube to the vascular entry device.
9.Tilt the injector head (or syringe interface module) down. 
* Refer to the injector operation manual for further instructions.
Removing the Syringe
10.To detach the syringe when the procedure has been completed, Remove it from the injector head. Discard all used components.
* Refer to the injector operation manual for further instructions.
11.Check the integrity of each primary package before use!
12.Confirm syringe model and injector model compatibility per Table 1 above.
13.Remove the syringe from the package. Attach the syringe to the injector according to the injector instructions for use.
14.Use the injector to push the piston of the syringe to the front of the barrel.
15.Remove the sheath from the conical fitting. Assemble the J shape tube/ spike on the conical fitting of the syringe.
16.Draw the required contrast media or saline into the syringe at the lowest speed of the injector to prevent air leakage.
17.Remove the J shape tube/spike from the syringe; discard it per the hospital or local regulations. Do not reuse!
18.Remove the protective cap from the conical fitting of the high pressure tube. Attach the tube to the syringe.
19.Attach the I.V. catheter or contrast media catheter to the other conical fitting of the high pressure tube. 
20.Expel the air in the catheter and tube. 
21.Inject the contrast media or saline in accordance with the instruction for use of the injector.
22.After the injection, disconnect the I.V. catheter or contrast media catheter and the high pressure tube.  Remove the syringe from the injector. 
23.Discard the syringe, tube and catheter immediately per hospital or local regulations.

More information,please contact us kindly.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA