AFCI -6KA TypeAC 1p+N 25amp TMA3-40 afdd breaker AFCI arc fault circuit breaker

Price $51.46 Compare
Min Order 120 Pieces
Shipping From Zhejiang, China
Popularity 308 people viewed
Quantity
+-
 

Taimu Electrical (Hangzhou)Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
TMA3-40 6kA C25 TypeAC 1p+N
Low Voltage Circuit Breakers
Electric Type
High-Speed Circuit Breaker
Air
Fixed
AFDD
1P+N
Circuit Breaker
Overcurrent Protection, RCCB
VDE, ISO9001-2000, CE, CB, Ukca, NF
IEC/En 62606 & IEC 61009-1
1P+N
B, C, D
6A, 10A, 16A, 20A, 25A, 32A, 40A
Type A, AC
30mA, 100mA, 300mA
2, 000A
6kA
3
afdd and rcd
afdd circuit breaker
arc detection device
Timelec, OEM / Private Label brands
White Gift Box, Yellow Carton Box
115 x 69.6 x 18 mm
China
8536200000
Product Description
Product Description

AFDD, Arc-Fault Detection Device, or being called AFCI, Arc Fault Circuit Interrupter, in North Amerca, in comply wtih IEC/BS EN 62606.
In terms of circuit protection,Timelec has MCB for short-circuit and overload protection, RCD (RCCB) for residual current protection; yet not safe enough. According to statistics, in terms of electrical safety, 90% of fires are caused by electric arc, and we need AFDD for arc protection.

 

Timelec AFDD is AFDD+RCBO, offering short-circuit, overload, residual current, arc and over-voltage protection, meeting the standard of IEC/BS EN 62606 and IEC/BS EN 61009-1, and it selectively distinguishes a harmless arc from a potentially dangerous arc. For example, it breaks the circuit when it detects electric arc which is a signature of loose connections in home-wiring, as loose connection can develop over time and sometimes become hot enough to cause house fires.
 

Product Parameters
Product categoryCIRCUIT BREAKER
Product typeARC FAULT DETECTION DEVICES (AFDDs)
Product modelTMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data StandardIEC/EN 62606 & IEC 61009-1
Electrical featuresRated curret (In)6A,10A,16A,20A,25A,32A,40A
Trip curveB, C, D
ModelElectronic
RCD TypeAC, A
Pole1P+N
Rate voltage (Ue)240V
Insulation voltage(Ui)500V
Rated frequency50Hz
Energy limiting class3
Rated residual operating current (IΔn)30mA, 100mA, 300mA
Rated breaking capacity (Icn)6KA
Rated operating short circuit breaking capacity (Ics)6KA
Rated residual making and breaking capacity(IΔm)2000A
Rated impulse withstand voltage (Uimp)4KV
Surge current resistance / at (8/20) μs3KA
Overvoltage protection270V-300V
Electrical life4,000
Pollution degree2
Mechanical featuresMechanical life20,000
Protection degreeIP20
Ambient temperature (with daily averages35°C)-25°C +40°C
Storage temperature-25°C +70°C
InstallationTerminal connection typeCable, busbar
Connection capacity (input)25mm2
Connection capacity (output)16mm2
Tightening torque (input)2.5Nm
Tightening torque (output)1.2Nm
35mm DIN rail
 
 
FAQ
What are arcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)

What causes arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.

Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire

According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation. 


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

Timelec AFDD (AFCI) total length, 115mm.
Compact yet not a compromise.

It is your best choice for overall protection and prevention in domestic and commercial applications.

Timelec offers customization:

Print: laser / pad;
Package: white gift box for selected product types for value adding;
                  yellow carton box for full range as bulk package.
Product design: based on volume to open new mould.
 
Certifications

 

Packaging & Shipping

White gift box: 1 pcs / gift box;


Yellow carton box: 60 pcs / carton box.

As a package in the distribution channel,
Timelec offers a corrugated carton box:

High quality,
High edge crush resistence,
Neutral print in black.
 

 