Breaker 6-40A AFCI Arc Fault Interrupters AfCI Breaker

Price $48.86 Compare
Min Order 120 Pieces
Shipping From Zhejiang, China
Popularity 219 people viewed
Quantity
+-
 

Taimu Electrical (Hangzhou)Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
TMA1-40 1P+N 6kA C40 TypeA
Low Voltage Circuit Breakers
Electric Type
High-Speed Circuit Breaker
Air
Fixed
RCBO
1
Circuit Breaker
Circuit-Breaker Failure Protection, Overcurrent Protection, RCCB
ISO9001-2000, CE, CB, Ukca, NF
IEC/En 62606 & IEC 61009-1
B, C
6A, 10A, 16A, 20A, 25A, 32A, 40A
Type AC, a
30mA, 100mA, 300mA
2, 000A
3
afdd rcbo
afdd guide
Afdd Arc Fault Detection Device
Timelec
Single Gift Box, Carton Package
115 x 69.6 x 18 mm
China
8536200000
Product Description
Product Description

AFDD, Arc-Fault Detection Devices , or being called AFCI, Arc Fault Circuit Interrupter, in North Amerca, in comply wtih IEC/BS EN 62606.
In terms of circuit protection,Timelec has MCB for short-circuit and overload protection, RCD (RCCB) for residual current protection; yet not safe enough. According to statistics, in terms of electrical safety, 90% of fires are caused by electric arc, and we need AFDD for arc protection.

 

Timelec AFCI is AFDCI+RCBO, offering short-circuit, overload, residual current, arc and over-voltage protection, meeting the standard of IEC/BS EN 62606 and IEC/BS EN 61009-1, and it selectively distinguishes a harmless arc from a potentially dangerous arc. For example, it breaks the circuit when it detects electric arc which is a signature of loose connections in home-wiring, as loose connection can develop over time and sometimes become hot enough to cause house fires.
 

Product Parameters


Product categoryCIRCUIT BREAKER
Product typeARC FAULT DETECTION DEVICES (AFDDs)
Product modelTMA1-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data StandardIEC/EN 62606 & IEC 61009-1
Electrical featuresRated curret (In)6A,10A,16A,20A,25A,32A,40A
Trip curveB, C, D
ModelElectronic
RCD TypeAC, A
Pole1P+N
Rate voltage (Ue)240V
Insulation voltage(Ui)500V
Rated frequency50Hz
Energy limiting class3
Rated residual operating current (IΔn)30mA, 100mA, 300mA
Rated breaking capacity (Icn)6KA
Rated operating short circuit breaking capacity (Ics)6KA
Rated residual making and breaking capacity(IΔm)2000A
Rated impulse withstand voltage (Uimp)4KV
Surge current resistance / at (8/20) μs3KA
Overvoltage protection270V-300V
Electrical life4,000
Pollution degree2
Mechanical featuresMechanical life20,000
Protection degreeIP20
Ambient temperature (with daily averages35°C)-25°C +40°C
Storage temperature-25°C +70°C
InstallationTerminal connection typeCable, busbar
Connection capacity (input)25mm2
Connection capacity (output)16mm2
Tightening torque (input)2.5Nm
Tightening torque (output)1.2Nm
35mm DIN rail
 
 What are arcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)

What causes arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.

Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire:




According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation. 

Since 2014, IEC 60364 recommends surrounding the installation and application environments of AFDDs in residential and commercial buildings:
In locations with sleeping accommodations (e.g., hotels, nursing homes, bed-rooms in homes)
In locations with risks of fire due to high quantities of flammable materials (e.g., barns, wood-working shops, stores of combustible materials)
In locations with combustible constructional materials (e.g., wooden buildings)
In fire propagating structures (e.g. high-rise buildings)
In locations where irreplaceable goods are housed (e.g., museums)
It is recommended that AFDDs be installed at the place of origin of the low voltage final circuit to be protected (i.e., switchboard of an electrical installation ).

More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

Timelec AFDD (AFCI) total length, 115mm.
Compact yet not a compromise.

It is your best choice for overall protection and prevention in domestic and commercial applications.

Timelec offers customization:

Printing method: laser / pad printing;
Package: white gift box for selected product types for value adding;
                  carton box for full range as bulk package.
Product design: based on volume to open new mould.
 
Certifications

 

Packaging & Shipping

White gift box: 1 pcs / gift box;


Yellow carton box: 60 pcs / carton box.