Reliable 63A Residual Current Circuit Breaker with 30mA Sensitivity

Price $10.90 Compare
Min Order 120 Pieces
Shipping From Zhejiang, China
Popularity 232 people viewed
Quantity
+-
 

Taimu Electrical (Hangzhou)Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
TMRO10-63 type Ac 63A 2P
Low Voltage Circuit Breakers
Electric Type
High-Speed Circuit Breaker
Air
Fixed
RCBO
4
Circuit Breaker
Overcurrent Protection, Short circuit
ISO9001-2000, CE, CB, CCC
IEC 61009-1
4P, 2P
B,C,D
63A
Electromagnetic
A
30mA,100mA,300mA
6KA,10KA
3
20, 000
20, 000
residual current device types
Timelec, OEM / Private Label brands
White Gift Box, Yellow Carton Box
103 X 103 X 78 mm
China
8536200000
Product Description
Product Description

RCBO, Residual-current Circuit Breaker with Overcurrent protection, or being called GFCI, Ground Fault Circuit Interrupter, meeting the standard of IEC/BS EN 61009-1, GB16917, is a circuit breaker with the functions of MCB and RCD (RCCB) effectively combined. Timelec RCBO protection against overload, short-circuit and residual current, and has two types depending on its tripping mechanism, respectively ELE (ELEctronic) and ELM (ELectroMagnetic), and has mainly 4 types depending on the waveform and frequency of fault current, namely Type Ac, Type A, Type F, Type B, being selected (mandatorily) in national standards through different countries.

Product Parameters
Product categoryCIRCUIT BREAKER
Product typeResidual current operated circuit-breakers with integral overcurrent protection (RCBO)
Product modelTMRO10-63
Business 
information
MOQ: 120pcs
Payment: T/T, L/C
Delivery time: 15-60 days
Loading Port: Ningbo or Shanghai, China
Certification: ISO9001:2015
Logo
:
pad printing, laser printing  (customized design are acceptable)
Unique selling propositionPrevention from overloading and short-circuit currents,
Detection of the earth leakage current.
Protection against indirect contacts and direct contacts.
Preventing fire hazard in cause of circuit fault.
Widly used in residual building and other recombiner distribution boxes
Technical data StandardIEC 61009-1, GB16917.1
Electrical featuresRated current (In)6A, 10A, 16A, 20A,25A, 32A, 40A, 50A, 63A
Trip curveB, C, D
ModelElectronic/Electromagnetic
RCD TypeAC, A
Pole2P, 4P
Rate voltage (Ue)240V/415V
Insulation voltage(Ui)500V
Rated frequency50/60Hz
Energy limiting class3
Rated residual operating current (IΔn)30mA, 100mA, 300mA
Rated breaking capacity (Icn)6KA/10KA
Rated operating short circuit breaking capacity (Ics)6KA/7.5KA
Rated residual making and breaking capacity(IΔm)3000A
Rated impulse withstand voltage (Uimp)4KV
Surge current resistance / at (8/20) μs3KA
Electrical life4,000
Pollution degree2
Mechanical featuresMechanical life20,000
Protection degreeIP20
Ambient temperature (with daily averages35°C)-25°C +40°C
Storage temperature-25°C +70°C
InstallationTerminal connection typeCable, busbar
Connection capacity (input)25mm2
Connection capacity (output)25mm2
Tightening torque (input)2.5Nm
Tightening torque (output)2.5Nm
35mm DIN rail