Sm1 Series Moulded Case Circuit Breakers

Price $9.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 456 people viewed
Quantity
+-
 

Elecal Electric Appliance Co., Ltd.

VIP   Audited Supplier 10 years
Profile Certified by SGS/BV
SM1
High Voltage Circuit Breakers
Electric Type
High-Speed Circuit Breaker
Air
Fixed
Moulded Case Circuit Breaker
4
Circuit Breaker
Conventional Circuit Breaker
ELECAL
Carton
Wenzhou
85363000
Product Description
1. Application
SM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.

2. Main Technical Specification(table1)
TypeRated
current (A)
Polenum-berRatedinsui-atingvolt-age(V)Rated
operat-ingvolt-age(V)
Arcing-
over
distance
(mm)
Ultimate
short
circuit
breaking
capacity
(KA)
Servies
short
circuit
breaking
capacity
(KA)
Operation
perform-
ance
Utiliza-tioncat-egory
LoadUnload
SM1-63L(6),10
16,20
25 ,32
40,50
63
3, 4500V400V0251815008500A
SM1-63M05035
SM1-100L(10),16
20,25
32,40
50,63
80,100
800V0(≤50)3522
SM1-100M0(≤50)5035
SM1-100H0(≤50)855010007000
SM1-225L100,125
160,180
200,225
≤503522
SM1-225M≤505035
SM1-225H≤50855010004000
SM1-400L225,250
315,350
400
≤505035
SM1-400M≤1006542
SM1-630L400,500
630
≤1005035
SM1-630M≤1006542
SM1-630H≤10010065
SM1-800M630,700
800
3≤1007550
SM1-800H≤10010065
SM1-1250M1000,1250≤10010065
SM1-1250H≤10012575
SM1-1600M1600≤10015080


Note: 6A without thermal protection 
The N-pole of four-poles breaker is sited at the right side of the product has four types: 
Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles. 
Type B: Without current trip-release on N pole which closing and opening with the other poles. 
Type C: With current trip-release which closing and opening with the other three poles.
Type D: With current trip-release which making all the time not closing and opening with the other three poles. 

3. Protection Characteristic
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker). 



Table2
Rated current of release (A)Thermodynamic release( ambient temperature ) land +40°C marine +45°COperating current of magnetic release (A)
1.05In(cold state) Inoperative time(h)1.30In(heat state) Operative time(h)
10≤In≤63≥ 1< 110In±20%
63<In≤100≥ 2< 2
100≤In≤800≥ 2< 25In±20% 10In±20%


Table3
Rated currentThermodynamic release ( ambient temperature ) land +40°C marine +45°COperating current of magnetic release (A)
of release (A)1.0In(cold state) non-trip time(h)1.20In(heat state) trip time (h)1.50In(heat state) trip time (h)7.2In(cold state) trip time(h)
10 ≤ In ≤ 225≥ 2<2≤ 4min4s < Tp ≤ 10s12In±20%
225 ≤ In ≤ 630≤ 8min6s < Tp ≤ 20s


4. Accessories of Circuit breaker
4.1 The external accessories of the breaker
Motor-driven operation device
1) Wiring diagram of type CDM electromagnetic operation device(fitting SM1-63,100,225) seethe following drawing (wiring diagram of the external accessories of the breaker in the dotted frame)

 

 



Code description: SB1 SB2 stand for push button.(provided by users themselves) Number "1" "2" "3" stand for number of wiring terminals.
Voltage rating: AC50Hz 230V 400V DC 220V
2) Wiring diagram of type CD motor-driven operation device (fitting SM1-400 630 800) seebelows (wiring diagram of the external accessories of the breaker in the dotted frame)

 




Code description: SB1 SB2 stand for push button. (provided by users themselves) "X" stands for line connection terminals
Voltage rating: AC50Hz 230V 400V DC 220V



Rotary handle operation device
The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle ,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation, one is "A" modelsquare handle , the other is "B" model round handle.

 



4.2 Release pattern and accessories code

SHT: Shunt release; UVR: Under-voltage release;AX: Auxiliary contact; AL: Alarm contact
Release patternand accessories codeName/TypeSM1-63,
100, 225
SM1-400SM1-630SM1-800
200, 300No accessories200: magnetic release (only short circuit protection)300: thermal magnetic release(both overload and short circuit protection)
208, 308Alarm contact    
210, 310Shunt release    
220, 320Auxiliary contact    
230, 330Under-voltage release    
240, 340Shunt release
Auxiliary contact
    
250, 350Shunt release
Under-voltage release
    
260, 360Two group of auxiliary contact    
270,370Under-voltage release
Auxiliary contact
    
218, 318Shunt release
Alarm contact
    
228, 328Alarm contact Auxiliary contact    
238, 338Under-voltage releaseAlarm contact    
248, 348Shunt release, Alarm contact,Auxiliary contact    
268, 368Two group of auxiliary contact,Alarm contact    
278, 378Shunt release, Alarm contact, Under-voltage release    

According to user's demands, accessories could lead to direct wire outcoming or line wiringterminals could be added(please mark out in case of making order).

Under-voltage release
Wring diagram of the under-voltage module connected externally (the internal accessories inthe dotted frame)Ue: AC50Hz 230V, 400V


 

 



When the operation voltage is 35%~70% of the rated voltage, the under-voltage release shouldmake the breaker trip correctly.When the operation voltage is 85%~110% of the rated voltage, the under-voltage release shouldmake the breaker close.In case of the operation voltage less than 35% of the rated voltage, the under-voltage shouldprevent the breaker from closing.Note: Only the under-voltage release should be energized in advanced, the breaker could berecramped and turned-on, otherwise the breaker will be damaged.


Shunt release
Scheme of wiring(the internal accessories in the dotted frame)"K" is the slow motion switch normal-close contact connect the coil in series in the shunt release.It turns-on or turns-off voluntarily as soon as the breaker on or off.

 



Voltage rating: AC50Hz 230V or 400V, DC 110V 220VThe shunt release should make the breaker trip reliably when the operation voltage is 70%~110%of the rated control voltage.


 
Alarm contact
The position of the breaker in "off" or "on" 
The position of the breaker in "free trip" (alarm)B11 and B12 switch from "close" to "open", statusof B11 and B14 switch from "open" to "close"
 
Auxiliary Contact
When the breaker is in"off" For the breaker with frame current400A and above
 For the breaker with frame current225A and below
When the breaker is in"on"When the breaker is in "off", the contacts switch from "close" to "open".When the breaker is in "off",the contacts switch from "open"to close"


, ,
TypeOutline Dimensions(mm)
Front panel connection
WW1LL1L2HH1H2H3H4CDEFGW2W3
SM1-63L76501351701177492 748528.548221410075
SM1-63M76501351701178298.528748528.548221410075
SM1-100L9260150185132688624748835.5502217.5  
SM1-100M92601501851328610424748835.5502217.512290
SM1-100H92601501851328610424748835.5502217.5  
SM1-225L1077016521514486110245410231.5502217  
SM1-225M10770165215144103127245410231.5502217142105
SM1-225H10770165215144103127245410231.5502217  
SM1-400L15096257357224105155388612864.58965φ6198144
SM1-400M1821162703702341101604386134708965φ9  
SM1-630L1821162703702341101604386134708965φ9240174
SM1-630M1821162703702341101604386134708965φ9  
SM1-630H2101402803802431061453330128       
SM1-800M2101402803802431061453330128       
SM1-800H2101402803802431061453330128       
SM1-1250M210140393  200           
SM1-1250H210140393  200           
SM1-1600M210140393  200           
 
TypeOutline Dimensions(mm)Installation
Dimensions
Back panel connectionPlug-in connection
L4H5H6φDφD1L5L6H7H8H9H10JKφd1MABφd
SM1-63L117446688          251173.5
SM1-63M117446688          251173.5
SM1-100L1296810826169216850627417.556606.5M8301294.5
SM1-100M1296810826169216850627417.556606.5M8301294.5
SM1-100H1296810826169216850627417.556606.5M8301294.5
SM1-225L126661102020941835069.584.517.554706.5M8351265
SM1-225M126661102020941835069.584.517.554706.5M8351265
SM1-225H126661102020941835069.584.517.554706.5M8351265
SM1-400L1946012033331692796083.5106.521129608.5M10441947
SM1-400M2006512536361692996092110211231008.5M12582007
SM1-630L2006512536361692996092110211231008.5M12582007
SM1-630M2006512536361692996092110211231008.5M12582007
SM1-630H 128             702437.2
SM1-800M 128             702437.2
SM1-800H 128             702437.2
SM1-1250M                  
SM1-1250H                  
SM1-1600M                  
le> SM1-1250H 210 140 393 200 SM1-1600M 210 140 393 200 
<t, d="" bgcolor="#ffffff" height="20" align="middle">,
TypeOutline Dimensions(mm)Installation
Dimensions
Back panel connectionPlug-in connection
L4H5H6φDφD1L5L6H7H8H9H10JKφd1MABφd
SM1-63L117446688          251173.5
SM1-63M117446688          251173.5
SM1-100L1296810826169216850627417.556606.5M8301294.5
SM1-100M1296810826169216850627417.556606.5M8301294.5
SM1-100H1296810826169216850627417.556606.5M8301294.5
SM1-225L126661102020941835069.584.517.554706.5M8351265
SM1-225M126661102020941835069.584.517.554706.5M8351265
SM1-225H126661102020941835069.584.517.554706.5M8351265
SM1-400L1946012033331692796083.5106.521129608.5M10441947
SM1-400M2006512536361692996092110211231008.5M12582007
SM1-630L2006512536361692996092110211231008.5M12582007
SM1-630M2006512536361692996092110211231008.5M12582007
SM1-630H 128             702437.2
SM1-800M 128            702437.2
SM1-800H 128             702437.2
SM1-1250M                  
SM1-1250H                  
SM1-1600M                  

Message Type