SRPM155L86
Industrial
High Speed
Three-Phase
Driving
Protection Type
8
Variable Frequency Starting
ISO9001, CE, RoHS
Mc-Motor
5000rpm-7000rpm
Water(Glycol) Cooling
50kw--132kw
Air Cooling, Water Cooling, Oil Cooling
H/F
B3, B5, B35
IP23/54
mc motor
1PC/ Carton ( Wood /Paper Box Optional)
TBD (based on real motor dimension)
China
8501520000
Product Description
60kw 6000-7000rpm AC 3 Phase Brush-less Electrical High Speed PM Motor

Product Feature
1.Suitable for the 6000-7000rpm Rated Speed
2.Reserve a large margin of security
3.Low power & low torque
4.High efficiency 93.2%
5.Small size 30kg
6.Low noise low vibration
7.The autonomous patented cooling structure
Specifications
Model type: SRPM155L86
Voltage: 380-400V AC
Rated Power: 60-132KW
Rated Speed:6000-7000rpm
Isolation: H/F
Cooling Method:Air /Water (glycol)/Oil
Ingress Protection:IP54
Duty type: S1
Pole:8
Rated Torque: 11.5 N.m






Other motors you will be interested in
FAQ
1. Can performanent magnet synchronous motor be used as generator?
Yes. Permanent magnet synchronous motor can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor?
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.
3. Any special technical request on this motor's VFD driver? And Do you have such driver?
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.
4. Is there any protective measures to defend permanent magnet rotor from failure?
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.
5. Where is this permanent magnet synchronous motor normally used to?
This permanent magnet synchronous motor is normally used to variable frequency speed situation.

Product Feature
1.Suitable for the 6000-7000rpm Rated Speed
2.Reserve a large margin of security
3.Low power & low torque
4.High efficiency 93.2%
5.Small size 30kg
6.Low noise low vibration
7.The autonomous patented cooling structure
Specifications
Model type: SRPM155L86
Voltage: 380-400V AC
Rated Power: 60-132KW
Rated Speed:6000-7000rpm
Isolation: H/F
Cooling Method:Air /Water (glycol)/Oil
Ingress Protection:IP54
Duty type: S1
Pole:8
Rated Torque: 11.5 N.m






Other motors you will be interested in
Motor type | Voltage (V AC) | Rated power (kW) | Rated torque (N.m) | Rated speed (rpm) | Efficiency (%) | Duty type | Insulation | Ingress protection | Pole Number | Weight (kg) | Cooling Method | position signal |
SRPM160H4XO15 | 380 | 15 | 5.96 | 24000 | 96.5 | S1 | H/F | IP67 | 4 | 12 | Oil | Resolver |
SRPM160H4XO75 | 380 | 75 | 35.8 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 44 | Oil | Resolver |
SRPM160H4XO90 | 380 | 90 | 43 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 48 | Oil | Resolver |
SRPM205H4XO110 | 380 | 110 | 52.5 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 76 | Oil | Resolver |
SRPM205H4XO160 | 380 | 160 | 76.4 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 86 | Oil | Resolver |
SRPM205H4XO200 | 380 | 200 | 95.5 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 95 | Oil | Resolver |
FAQ
1. Can performanent magnet synchronous motor be used as generator?
Yes. Permanent magnet synchronous motor can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor?
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.
3. Any special technical request on this motor's VFD driver? And Do you have such driver?
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.
4. Is there any protective measures to defend permanent magnet rotor from failure?
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.
5. Where is this permanent magnet synchronous motor normally used to?
This permanent magnet synchronous motor is normally used to variable frequency speed situation.