SRPM95H2W5.5
Industrial
High Speed
Three-Phase
Driving
Protection Type
2
Variable Frequency Starting
ISO9001, CE, RoHS
Mc-Motor
80000rpm
Air Cooling
2
H/F
IP54/IP67
Ib3, Ib5, Ib35
96%
20kgs
S1
5.5kw
mc motor
1PC/ Carton ( Wood /Paper Box Optional)
TBD (based on real motor dimension)
China
8501520000
Product Description
5.5kw 80000rpm High Speed Synchronuns MotorPermanent Magnetic Permanent Motor for Vapor Blower

Product Feature
1.Suitable for the 60000rpm Rated Speed
2.Reserve a large margin of security
3.High power & High torque
4.High efficiency
5.Small size 22kg
6.Low noise low vibration
7.The autonomous patented cooling structure
Specifications
Model type: SRPM95H2W7.5
Voltage: 380-400V AC
Rated Power: 5.5KW
Rated Speed:80000rpm
Isolation: H
Cooling Method:Air Cooling
Ingress Protection:IP67(IP54 option)
Duty type: S1
Pole:2
Rated Torque: 2.56 N.m

Power: 5KW-2MW
Speed:2500rpm-100000rpm
Voltage:110v-690v



Other motors you will be interested in
FAQ
1. Can performanent magnet synchronous motor be used as generator?
Yes, Permanent magnet synchronous motor can be used as a generator.
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor?
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.
3. Any special technical request on this motor's VFD driver? And Do you have such driver?
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.
4. Is there any protective measures to defend permanent magnet rotor from failure?
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.
5. Where is this permanent magnet synchronous motor normally used to?
This permanent magnet synchronous motor is normally used to variable frequency speed situation.

Product Feature
1.Suitable for the 60000rpm Rated Speed
2.Reserve a large margin of security
3.High power & High torque
4.High efficiency
5.Small size 22kg
6.Low noise low vibration
7.The autonomous patented cooling structure
Specifications
Model type: SRPM95H2W7.5
Voltage: 380-400V AC
Rated Power: 5.5KW
Rated Speed:80000rpm
Isolation: H
Cooling Method:Air Cooling
Ingress Protection:IP67(IP54 option)
Duty type: S1
Pole:2
Rated Torque: 2.56 N.m
Company Introduction
MC MOTOR is a high-tech manufacturing enterprise which focuses on special permanent magnet motor. MC MOTOR globally leads high-speed motor technology with the strongest R&D capability obtained more than 100 intellectual property patents. Our products are applied to high-speed compressor, fan, turbine, pump, supercharger and new energy fuel cell compressor system in vehicles, and other new emerging industries. New designs are more than 50 types from 8kw to 200kw, between 5000rpm and 24000rpm. Besides, product quality is guaranteed because all production process strictly abide by ISO9001-2015.

Main Service
We can provide customers with customized services, according to your motor application scenarios and needs, so that you can apply rationally and save costs.
Customizing Range:
Power: 5KW-2MWSpeed:2500rpm-100000rpm
Voltage:110v-690v
Custom case



Other motors you will be interested in
Motor type | Voltage | Rated power | Rated torque (N.m) | Rated speed | Efficiency | Insulation | Ingress protection | Pole Number | PIC | Weight | Cooling Method | Position Signal | Duty Type | Installation Method |
(V AC) | (kW) | (rpm) | (%) | (kg) | ||||||||||
SPRM( General) | 380 | 5.5-110 | 10-420 | 10000-80000 | 95.00% | H/F | IP54/IP67 | 8 | 19-112 | Water | Resolver | S1-S9 | B35 | |
SPRM( General) | 380 | 4-37 | 35-463 | 15000-24000 | 95.00% | H/F | IP54/IP67 | 8 | 14-100 | Air | N/A | S1-S9 | B35 | |
SPRM( General) | 380 | 37-350 | 35-463 | 12000-24000 | 95.00% | H/F | IP54/IP67 | 8 | 14-25 | Oil | N/A | S1-S9 | B35 | |
SRPM112H4F7.5C | 380 | 7.5 | 3.4 | 21000 | 95 | H/F | IP54 | 4 | 12 | Air | N/A | S1-S9 | B35 | |
SRPM112H4F7.5C | 380 | 7.5 | 3 | 24000 | 95 | H/F | IP54 | 4 | 12 | Air | N/A | S1-S9 | B35 | |
SRPM112H4F15F | 380 | 15 | 6 | 24000 | 95 | H/F | IP54 | 4 | 20 | Air | N/A | S1-S9 | B35 | |
SRPM112H4F18.5 | 380 | 18.5 | 8.41 | 21000 | 95 | H/F | IP54 | 4 | 25 | Air | N/A | S1-S9 | B35 | |
SRPM180L8F18.5 | 380 | 18.5 | 33.3 | 5300 | 95 | H/F | IP54 | 8 | 25 | Air | N/A | S1-S9 | B35 | |
SRPM130H4F22 | 380 | 22 | 10 | 21000 | 95 | H/F | IP54 | 4 | 33 | Air | N/A | S1-S9 | B35 | |
SRPM130H4F37 | 380 | 37 | 19.63 | 18000 | 95 | H/F | IP54 | 4 | 47 | Air | N/A | S1-S9 | B35 | |
SRPM168H2F75C | 380 | 75 | 21.07 | 34000 | 95 | H/F | IP54 | 2 | 50 | Air | N/A | S1-S9 | B35 | |
SRPM112H4F15 | 380 | 15 | 5.96 | 24000 | 96.5 | H/F | IP54 | 4 | 12 | Air/Water | N/A | S1-S9 | B35 | |
SRPM112H4W5.5 | 380 | 10 | 2.5 | 21000 | 94 | H/F | IP67 | 4 | 14 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W10 | 380 | 10 | 8 | 12000 | 94 | H/F | IP67 | 4 | 20 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W20 | 380 | 20 | 8 | 24000 | 96.5 | H/F | IP54 | 4 | 25 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W22B | 380 | 22 | 8.75 | 24000 | 96.5 | H/F | IP54 | 4 | 25 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W25 | 380 | 25 | 15.9 | 15000 | 96.5 | H/F | IP54 | 4 | 28 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W30 | 380 | 30 | 17.9 | 16000 | 96.5 | H/F | IP54 | 4 | 32 | Water | N/A | S1-S9 | B35 | |
SRPM210M4W55B | 380 | 55 | 52.5 | 10000 | 95.4 | H/F | IP54 | 4 | 55 | Water | N/A | S1-S9 | B35 | |
SRPM210H4W60 | 380 | 60 | 45.8 | 12500 | 96.5 | H/F | IP54 | 4 | 80 | Water | N/A | S1-S9 | B35 | |
SRPM210M4W75C | 380 | 75 | 71.6 | 10000 | 96.5 | H/F | IP54 | 4 | 95 | Water | N/A | S1-S9 | B35,V1 | |
SRPM130H4W20 | 380 | 20 | 3.3 | 60000 | 95.00% | H/F | IP54/IP67 | 4 | 45 | Water | N/A | S1-S9 | B35 | |
SRPM95H2W18 | 380 | 18 | 0.667 | 75000 | 95.00% | H/F | IP54/IP67 | 2 | 45 | Water | N/A | S1-S9 | B35 | |
SRPM95H2W5.5 | 380 | 5.5 | 2.29 | 80000 | 95.00% | H/F | IP54/IP67 | 2 | 25 | Water | N/A | S1-S9 | B35 | |
SRPM180M8O30 | 380 | 30 | 23.8 | 12000 | 96.5 | H/F | IP67 | 8 | 12 | Water/Oil | N/A | S1-S9 | B35 | |
SRPM165H4XO37 | 380 | 37 | 17.7 | 20000 | 96.50% | H/F | IP54/IP67 | 4 | 100 | Oil | N/A | S1-S9 | B35 | |
SRPM214H4O50 | 380 | 50 | 19.9 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 100 | Oil | N/A | S1-S9 | B35 | |
SRPM214H4O75 | 380 | 75 | 29.8 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 120 | Oil | N/A | S1-S9 | B35 | |
SRPM214H4O100 | 380 | 100 | 39.8 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 150 | Oil | N/A | S1-S9 | B35 | |
SRPM214H4O124 | 380 | 124 | 66 | 18000 | 95.00% | H/F | IP54/IP67 | 4 | 250 | Oil | N/A | S1-S9 | B35 | |
SRPM160H4XO90 | 380 | 90 | 43 | 20000 | 96.5 | H/F | IP67 | 4 | 48 | Oil | N/A | S1-S9 | B35 | |
SRPM205H4XO110 | 380 | 110 | 52.5 | 20000 | 96.5 | H/F | IP67 | 4 | 76 | Oil | N/A | S1-S9 | B35 | |
SRPM205H4XO160 | 380 | 160 | 76.4 | 20000 | 96.5 | H/F | IP67 | 4 | 86 | Oil | N/A | S1-S9 | B35 | |
SRPM205H4XO200 | 380 | 200 | 95.5 | 15500 | 95.5 | H/F | IP67 | 4 | 350 | Oil | N/A | S1-S9 | B35 | |
SRPM205H4O220 | 380 | 200 | 131.1 | 16000 | 95.5 | H/F | IP67 | 4 | 310 | Oil | N/A | S1-S9 | B35 | |
SRPM290H4O350 | 380 | 350 | 167.1 | 20000 | 95.5 | H/F | IP67 | 4 | 530 | Oil | N/A | S1-S9 | B35 |
Motor type | Voltage (V AC) | Rated power (kW) | Rated torque (N.m) | Rated speed (rpm) | Efficiency (%) | Duty type | Insulation | Ingress protection | Pole Number | Weight (kg) | Cooling Method | position signal |
SRPM160H4XO15 | 380 | 15 | 5.96 | 24000 | 96.5 | S1 | H/F | IP67 | 4 | 12 | Oil | Resolver |
SRPM160H4XO75 | 380 | 75 | 35.8 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 44 | Oil | Resolver |
SRPM160H4XO90 | 380 | 90 | 43 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 48 | Oil | Resolver |
SRPM205H4XO110 | 380 | 110 | 52.5 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 76 | Oil | Resolver |
SRPM205H4XO160 | 380 | 160 | 76.4 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 86 | Oil | Resolver |
SRPM205H4XO200 | 380 | 200 | 95.5 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 95 | Oil | Resolver |
FAQ
1. Can performanent magnet synchronous motor be used as generator?
Yes, Permanent magnet synchronous motor can be used as a generator.
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor?
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.
3. Any special technical request on this motor's VFD driver? And Do you have such driver?
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.
4. Is there any protective measures to defend permanent magnet rotor from failure?
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.
5. Where is this permanent magnet synchronous motor normally used to?
This permanent magnet synchronous motor is normally used to variable frequency speed situation.