Underground, Power Station
Low and Medium Voltage Cable
DC & AC
XLPE
Bare
Round Wire
CCC, VDE, SGS BV
Kingyear
Yes
More Than 30years
Kingyear
Export Drum
Power Cable
Henan
8544492100
Product Description
4 5 core 35mm 50mm 70mm 95mm 120mm copper core pvc insulated power cable

Applications
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
Standard
IEC 60502, IEC60332, IEC 60754
Specification
1). Rated Voltage, No. of Core and Range of Sectional Area
2). DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
3). Voltage Test and Partial Discharge Test
Production process

Package
Package in Export Wooden or Steel Wooden or Steel Drums

Testing

Contact us

Applications
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
Standard
IEC 60502, IEC60332, IEC 60754
Specification
1). Rated Voltage, No. of Core and Range of Sectional Area
Rated voltage (kv) Sectional area (mm2) No. of core | 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
2). DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
3). Voltage Test and Partial Discharge Test
Rate voltage Uo (kv) Item | 0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Partial discharge test | Test voltage | - | - | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 |
Discharge capacity | - | - | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Production process

Package
Package in Export Wooden or Steel Wooden or Steel Drums

Testing

Contact us