power cable
Construction, Underground, Industrial, Power Station
Low and Medium Voltage Cable
AC Cable
XLPE
PVC
Round Wire
Bare Copper Wire
ISO, CCC, CE, RoHS, VDE
Yjv32
Rne Da
0.6/1kv
XLPE
PVC
Steel Wire Armour
1.5mm2-800mm2
1,2,3,4,5,3+1,3+2,4+1
ISO,Ce,CCC
RNE DA
Standard Export Drum
IEC60502
Hebei, China
8544601200
Product Description
4 core 5 core 35mm 95mm copper conductor xlpe power cable

Product Standard
This product is manufactured according to GB/T12706.1, equivalent to IEC60502.1. Or BS, DIN, ICEA standard as customer request.
Application
The product is suitable for power transmission and distribution lines with rated power frequency voltage up to and including 0.6/1KV.
Operating Performance
1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90ºC
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250ºC
4). The ambient temperature under installation should not below 0ºC
5). The bending radius of a cable should not be less than 15 times of the cable diameter.
6). The test voltage (A.C.): 3.5kV/5min.
7). The flame-retardant properties of cable comply with grade A, B, C of GB/T19666-2005 or IEC60332.
Construction:
Conductor: Solid or stranded copper,aluminum
Insulation: Cross-linked polyethylene( XLPE or PVC)
Circuit Identification: The insulation shall be red, black
Filler: Polypropylene lament with lapped binding tape
Inner Sheath: Polyvinyl chloride (Black)
Armor: Galvanized steel wire
Core-covering: Binding tape
Outer Sheath: Polyvinyl chloride (Black)
Package: Wooden Drum Package or Iron-wooden drum
Type and Name:
Specification:



Product Standard
This product is manufactured according to GB/T12706.1, equivalent to IEC60502.1. Or BS, DIN, ICEA standard as customer request.
Application
The product is suitable for power transmission and distribution lines with rated power frequency voltage up to and including 0.6/1KV.
Operating Performance
1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90ºC
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250ºC
4). The ambient temperature under installation should not below 0ºC
5). The bending radius of a cable should not be less than 15 times of the cable diameter.
6). The test voltage (A.C.): 3.5kV/5min.
7). The flame-retardant properties of cable comply with grade A, B, C of GB/T19666-2005 or IEC60332.
Construction:
Conductor: Solid or stranded copper,aluminum
Insulation: Cross-linked polyethylene( XLPE or PVC)
Circuit Identification: The insulation shall be red, black
Filler: Polypropylene lament with lapped binding tape
Inner Sheath: Polyvinyl chloride (Black)
Armor: Galvanized steel wire
Core-covering: Binding tape
Outer Sheath: Polyvinyl chloride (Black)
Package: Wooden Drum Package or Iron-wooden drum
Type and Name:
Type | Designation | Applications |
YJV | Copper conductor,XLPE insulated,PVC sheathed power cable | For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. |
YJLV | Aluminum conductor,XLPE insulated,PVC sheathed power cable | |
YJY | Copper conductor, XLPE insulated,PE sheathed power cable | |
YJLY | Aluminum conductor, XLPE insulated,PE sheathed power cable | |
YJV22 | Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable | For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. |
YJLV22 | Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable | |
YJV23 | Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable | |
YJLV23 | Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable | |
YJV32 | Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable | For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. |
YJLV32 | Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable | |
YJV33 | Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable | |
YJLV33 | Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable |
Specification:
Type | No. of cores | Nom. Cross-section of conductor (mm2) | |
Copper conductor | Aluminum conductor | ||
YJV YJY | - | 1 | 1.5-800 |
- | YJLV YJLY | 2.5-800 | |
YJV22 YJV23 | YJLV22 YJLY23 | 10-800 | |
YJV YJY | - | 2 | 1.5-300 |
- | YJLV YJLY | 2.5-300 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4.0-300 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-300 | |
YJV YJY | - | 3 | 1.5-400 |
- | YJLV YJLY | 2.5-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | - | 4 | 1.5-400 |
- | YJLV YJLY | 2.5-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | - | 3+1 | 1.5-400 |
- | YJLV YJLY | 4.0-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | - | 5 | 1.5-400 |
- | YJLV YJLY | 2.5-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | - | 4+1 | 1.5-400 |
- | YJLV YJLY | 4.0-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | - | 3+2 | 1.5-400 |
- | YJLV YJLY | 4.0-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
The armoured single core cables are used for D.C. system only. As for A.C. system,non-magnetic armour material should be used, or a magnetic isolation should be applied. |