YX-4KUS-1-2
8000W
50Hz/60Hz
18 Months
91%
Accepted
LED Digital
Pure Sine Wave
Yassion
1PC/Box; 2PCS/CTN
436x197x82mm
Zhejiang, China
8504403090
Product Description

Product Description

 
ModelYX-4KUS-1-1YX-4KUS-2-1YX-4KUS-1-2YX-4KUS-2-2
Continuous Power4000W
Peak Power8000W
DC VoltageDC12VDC24VDC12VDC24V
AC Voltage100VAC or 110VAC or 120VAC ± 3V 220VAC or 230VAC or 240VAC ± 3V
No Load Current Draws1.2A0.5A1.2A0.5A
Max AC Input Current33A17.5A
DC Voltage Range10-15.5V20-31V10-15.5V20-31V
Low Voltage AlarmLo0:10.5V11V±0.3VLo0:21V22V±0.3VLo0:10.5V11V±0.3VLo0:21V22V±0.3V
Lo1:10.8V11.3V±0.3VLo1:21.6V22.6V±0.3VLo1:10.8V11.3V±0.3VLo1:21.6V22.6V±0.3V
Lo2:11.3V11.8V±0.3VLo2:22.6V23.6V±0.3VLo2:11.3V11.8V±0.3VLo2:22.6V23.6V±0.3V
Low Voltage Shut DownLo0:10.5V10.5V±0.3VLo0:21V21V±0.3VLo0:10.5V10.5V±0.3VLo0:21V21V±0.3V
Lo1:10.8V10.8V±0.3VLo1:21.6V21.6V±0.3VLo1:10.8V10.8V±0.3VLo1:21.6V21.6V±0.3V
Lo2:11.3V11.3V±0.3VLo2:22.6V22.6V±0.3VLo2:11.3V11.3V±0.3VLo2:22.6V22.6V±0.3V
Low Voltage Alarm RecoveryLo0:10.5V11.3V±0.3VLo0:21V22.6V±0.3VLo0:10.5V11.3V±0.3VLo0:21V22.6V±0.3V
Lo1:10.8V11.6V±0.3VLo1:21.6V23.2V±0.3VLo1:10.8V11.6V±0.3VLo1:21.6V23.2V±0.3V
Lo2:11.3V12.1V±0.3VLo2:22.6V24.2V±0.3VLo2:11.3V12.1V±0.3VLo2:22.6V24.2V±0.3V
Low Voltage Protection RecoveryLo0:10.5V12V±0.3VLo0:21V24V±0.3VLo0:10.5V12V±0.3VLo0:21V24V±0.3V
Lo1:10.8V12.3V±0.3VLo1:21.6V24.6V±0.3VLo1:10.8V12.3V±0.3VLo1:21.6V24.6V±0.3V
Lo2:11.3V12.8V±0.3VLo2:22.6V25.6V±0.3VLo2:11.3V12.8V±0.3VLo2:22.6V25.6V±0.3V
Over Voltage Shut Down15.7V±0.3V31.5V±0.3V15.7V±0.3V31.5V±0.3V
Over Voltage Recovery15.3V±0.3V30.6V±0.3V15.3V±0.3V29.5V±0.3V
Frequency50HZ ± 0.5HZ or 60HZ ± 0.5HZ
Output WaveformPure Sine Wave 
AC RegulationTHD<3% (Linear load)
Output Efficiency12V: up to 91%;       24V:up to 92%
Transfer relay rating30A
Transfer time AC to inverter and inverter to ACless than 30ms
Remote Control (Optional)Cable length: 15m is available. 
Power-Saving modeThe power saving mode will be activated when the output power is less than 5W. When output power is more than 10W, the inverter will automatically return to normal status.
Ignition FunctionConnect vehicles battery (or connect positive pole of vehicles' STARTER). The inverters start simultaneously When the vehicles start; The inverters will shut down meantime when the vehicles shut down.
Protection FunctionLow voltage alarmcode: F05Buzzer sounds and fault light turns red
Low voltage shutdowncode: F01Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.)
Over input voltage protectioncode: F02Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.)
over load alarmcode: F06Buzzer sounds and fault light turns red when output power is overloaded around 110%.  But the BUZZ and F06 code will not occured when the output power drop to a normal level within 20ms.
Over load protectioncode: F03The inverter shutdown when output power is overloaded around 120%, it need to be recovered by hand. 
Over temperature alarmcode: F07Buzzer sounds and fault light turns red when the inverter's internal temperature is higher than the limit value (90±5ºC).
Over temperature protectioncode: F04The inverter will automatically return to normal status when the internal temperature drops to 80±5ºC. 
 code: F08The display will show the code F08 when the thermostat in the inverters is broken 
Short circuit protectioncode:  F03Recover by hand 
Reverse polarity protection Built-in fuse
AC input overload protectioncode: F09The fan will start to work when the relay temperature is up to 60±5ºC; but it will stop to work when the relay temperature drops to 50±5ºC. The unit will alarm, and no AC output when relay temperature is up to 75±5ºC; But it will auto recover when the relay temperature drops to normal value. 
FuseInternal USB port 5V, 2.1A
Working Temperature-10°C--+50°CProduct Size436x197x82mm
Storage Temperature-30°C--+70°CPacking Size48x26x14cm
Warranty18 monthsN.W. / G.W. (KG)5.7KG/6.5KG
StartBipolar soft-startQuantity / Carton2pcs
Cooling WayIntelligent cooling fanCarton Size50x27x30cm
CertificationCE, E-mark, FCCCarton Weight14.0KG