Three Phase Energy-Saving Controller

Price $99.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 329 people viewed
Quantity
+-
 

Nanjing Linkelec Technology Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
LINK813S
Two Years
Two Years
Digital
0.5%~1%
Electronic Meter
AC and DC
19999
AUTO/MAN RANGZ
Frequency
LCD
LINKELEC
Carton
Customized
China
9028301400
Product Description
     Three phase energy-saving controller
1.Product profile
The three-phase rail type comprehensive measurement and control instrument is mainly used in the field of electricity information collection for three-phase power networks with frequencies ranging from 45 to 65Hz. It can measure all electrical parameters in the power grid and exchange data with the upper computer through communication. Users can set the internal parameters of the product according to the actual situation on site, which is convenient to use, easy to operate, and has high accuracy; It is widely used in various power Internet scenarios.
It can achieve high-precision measurement and metrology to meet measurement and other applications. Adopting standard DIN35mm rail installation and modular structural design, it can be easily installed inside the distribution box. Users can easily switch displays and set parameters on-site, making it flexible and convenient to use. It can directly replace conventional power transmitters and other auxiliary units as an advanced intelligent digital power grid front-end acquisition component, widely used in various control systems, substation automation systems, and distribution automation systems. It has the characteristics of easy installation, simple wiring, convenient maintenance, and small engineering quantity, and can flexibly network with various communication software.

2.Product specifications
performance parametersperformance indicators
accuracy classU, I: 0.2 level, P, Q, PF: 0.5 level, F: ±0.01 HZ, active power: 0.5S level, reactive power: 2 level
display modeLCD display
NetworkingThree-phase, four-wire
Input VoltageRated voltage3×220/380V AC
frequency range45~65Hz
overload capacity1.2Un (continuous); 2Un (10s allowed)
Measuring range0.5Un~1.2Un
functional consumption< 0.3VA per phase
Input currentRated currentDirect access: 5 (80) A
overload capacity1.2In (continuous); 20In (1s allowed)
Measuring range0 to 1.2 Imax with a threshold of 20 mA
functional consumption< 0.5VA per phase
switching inputsinput formActive wet node (external 220VAC ±20%)
isolation voltage4000Vac rms
switching outputsoutput formmechanical contacts
voltage withstand between contact and coilAC250V/5A,DC30V/5A
Built-in relayMaximum switching current80A
communication interfaceinterface formRS485, power infrared, wireless radio frequency
communication protocolsModbus-RTU protocol, radio frequency protocol
environmental conditionsOperating Temperature-20ºC~70ºC
storage temperature-40ºC~70ºC
Operating humidity0 to 95% non-condensing
Atmospheric pressure86kPa~106kPa
mechanical propertiesVibrationGB/T11287 severity level 1
ImpactGB/T14537 severity level 1
CollisionGB/T14537 severity level 1
electromagnetic compatibility performanceradio frequency electromagnetic field immunity testGB/T 17626.3-2006 severity level 3
Fast transient pulse group testGB/T 17626.4-2008 Severity level 4
Attenuated oscillatory wave immunity testGB/T 17626.12-1998 Severity level 3
electrostatic discharge testGB/T 17626.2-2006 severity level 4
Surge immunityGB/T 17626.5-2008 Severity level 4
RF conducted immunityGB/T 17626.6-2008 Severity level 3
radio interferenceGB/T 17215.211-2006 7.5.8 Class B equipment
degree of interference with industrial frequency magnetic fieldsGB/T 17626.8-2006 severity level 3
electrical insulation propertiesinsulation resistanceGBT 13729-2002, not less than 100MΩ
medium strengthGBT 13729-2002, Industrial frequency voltage 2KV, 1 min
Impulse voltageGBT 13729-2002,1.2/50μs,5KV
DimensionsH*W*D126mm*97mm*79mm
mounting methodrail mounted

3.Selection specifications
function moduleSerial numberfunction pointfunction point descriptionsthree-phase energy-saving controller
real-time measurements1phase voltagePhase voltages: Ua, Ub, Uc
2line voltageLine voltage: Uab, Ubc, Uca
3phase currentsPhase currents: Ia, Ib, Ic
4Active powerActive power: Pa, Pb, Pc, P
5Reactive powerReactive power: Qa, Qb, Qc, Q
6apparent powerApparent power: Sa, Sb, Sc, S
7Power factorPower factor: Pfa, Pfb, Pfc, Pf
8PhaseVoltage/current: ∠Ua, ∠Ub, ∠Uc, ∠Ia, ∠Ib, ∠Ic
9FrequencySystem frequency: F
Electricity metering10Active ElectricitySplit-phase and combined-phase bi-directional active energy
11reactive power metersSplit-phase and combined-phase bi-directional reactive energy
12The view is in the electric degreeSplit-phase and combined-phase visual energy
Control13RelayThe built-in relay can cut off the load directly
14air conditioning controlsIt can be realized to learn the code library and control the air conditioner
communication interface15Rs485 communication1 RS485 communication.
Supports MODBUS-RTU protocol;
Supports online via RS485 interface
Upgrading procedures
16wireless communicationsLoRa,Zigbee
17Power infrared38K power infrared.
Supporting MODBUS-RTU protocol
Note: "√" means this function is standard, "○" means this function is optional 

4.Product installation and schematic diagram
Appl  About our service :                  
*  We could provide 7* 24-hour phone call after-sales service. 
*  We provide a 2-year guarantee time and will change the meter for you within 1 year if there's something wrong with the product. Except for natural disasters or man-made reasons.
*  Recommend the most advanced application technology and management model in the industry to customers, and provide customers with detailed solutions
.

Package: 

Basic Information: