WT-LCT-0.69-100-3
Polypropylene Capacitor
General Purpose, AC / Motor, Power, Lighting, Air Conditioner, Fan
Surface Mount
1-400UF
Fixed Capacitor
Polypropylene
Low Frequency Coupling, High Frequency Coupling, Filter, Low Frequency Bypass, High Frequency Bypass
Polystyrene Capacitor
(UF%) - 5 ~ 10%
50 Hz / 60 Hz
≥ 200 * in
3kv / 10s
WENLIDA
Wooden
China
85044019
Product Description
PRODUCT INTRODUCTION:
The filter capacitor is suitable for reactive power compensation and harmonic control in the strong harmonic power supply system. The filter capacitor is connected with the reactor to improve the power factor of the power supply system while filtering, so that the power quality of the power grid can be effectively improved. It can be used in various working conditions of capacitive reactive power compensation and strong current harmonic filtering.
Compensation capacitor can be used in series with common series reactor to reduce reactive power loss, suppress harmonic amplification and improve power grid qualityCompensation capacitor can be used in series with common series reactor to reduce reactive power loss, suppress harmonic amplification and improve power grid quality.
MODEL DESCRIPTION:

SPECIFICATION SHEET:
Note: if the user needs the specifications not listed in the table can be designed separately
TECHNICAL PARAMETER:
a) Volume deviation: (UF%) - 5 ~ 10%
b) Loss tangent (Tan δ): 0.01% (UN 50 Hz, 20 ºC)
c) Frequency: 50 Hz / 60 Hz
d) Ambient temperature: upper limit + 55 ºC, lower limit - 30 ºC
e) Maximum allowable voltage: 1.1un (for gap use, no more than 8 hours per day)
f) Maximum over current: 1.8in, long-term operation, transition current no more than 2.5in
g) Surge current withstand capacity: ≥ 200 * in
h) Insulation withstand voltage: 3KV / 10s
i) Loss: less than 0.25w/kvar (including the loss of external discharge device)
j) The capacitor is of oil immersed type (or nitrogen filled dry type), with over-current, over-voltage, over temperature and pressure fusing and explosion-proof function. Polypropylene film is used as dielectric inside, with self-healing function.
k) The capacitor has built-in discharge resistance, and the residual voltage between terminals drops below 50V within 1 minute after the power supply is cut off.
CONDITIONS OF USE:
1.The altitude shall not exceed 2500 m;
2.The ambient temperature is - 20 ºC - + 55 ºC, the average temperature is not higher than + 35 ºC within 24 hours;
3.relative humidity: no more than 90%;
4.There is no corrosive gas, conductive dust and flammable and explosive media in the surrounding environment;
5.The seismic intensity shall not exceed grade 8;
6.For indoor installation, there should be good ventilation conditions around. If it is installed in the cabinet, there should be exhaust facilities.


The filter capacitor is suitable for reactive power compensation and harmonic control in the strong harmonic power supply system. The filter capacitor is connected with the reactor to improve the power factor of the power supply system while filtering, so that the power quality of the power grid can be effectively improved. It can be used in various working conditions of capacitive reactive power compensation and strong current harmonic filtering.
Compensation capacitor can be used in series with common series reactor to reduce reactive power loss, suppress harmonic amplification and improve power grid qualityCompensation capacitor can be used in series with common series reactor to reduce reactive power loss, suppress harmonic amplification and improve power grid quality.
MODEL DESCRIPTION:

SPECIFICATION SHEET:
COMPENSATING TYPE | |||||
Product name | Specification and model | Dimension(mm) diameter * height Width * depth * height | Terminal block | Rated capacity (uF) | Rated current (A) |
Cylindrical capacitor | WT-BCY-0.48-15-3 | D86*H245 | M6 | 207 | 17 |
WT-BCY-0.48-20-3 | D86*H290 | M6 | 276 | 24 | |
WT-BCY-0.48-25-3 | D86*H290 | M8 | 345 | 30 | |
WT-BCY-0.48-30-3 | D106*H290 | M8 | 414 | 36 | |
WT-BCY-0.48-40-3 | D116*H290 | M8 | 553 | 48 | |
WT-BCY-0.48-50-3 | D136*H290 | M8 | 691 | 60 | |
Aluminum stretch capacitor | WT-BCT-0.45-15-3 | 175*62*160 | M6 | 236 | 19 |
WT-BCT-0.45-20-3 | 175*62*160 | M6 | 314 | 26 | |
WT-BCT-0.45-25-3 | 175*62*223 | M6 | 393 | 33 | |
WT-BCT-0.45-30-3 | 202*102*165 | M8 | 472 | 38 | |
WT-BCT-0.45-40-3 | 202*102*230 | M8 | 629 | 51 | |
WT-BCT-0.45-50-3 | 202*102*230 | M8 | 786 | 72 | |
WT-BCT-0.48-15-3 | 175*62*160 | M6 | 207 | 17 | |
WT-BCT-0.48-20-3 | 175*62*223 | M6 | 276 | 24 | |
WT-BCT-0.48-25-3 | 175*62*223 | M6 | 345 | 30 | |
WT-BCT-0.48-30-3 | 202*102*165 | M8 | 414 | 36 | |
WT-BCT-0.48-40-3 | 202*102*230 | M8 | 553 | 48 | |
WT-BCT-0.48-50-3 | 202*102*230 | M8 | 691 | 60 | |
WT-BCT-0.525-15-3 | 175*62*160 | M6 | 173 | 16 | |
WT-BCT-0.525-20-3 | 175*62*223 | M6 | 231 | 22 | |
WT-BCT-0.525-25-3 | 202*102*165 | M8 | 289 | 27 | |
WT-BCT-0.525-30-3 | 202*102*165 | M8 | 346 | 33 | |
WT-BCT-0.525-40-3 | 202*102*230 | M8 | 462 | 44 | |
WT-BCT-0.6-30-3 | 202*102*165 | M8 | 265 | 29 | |
WT-BCT-0.6-40-3 | 202*102*230 | M8 | 354 | 38 | |
WT-BCT-0.69-30-3 | 202*102*165 | M8 | 201 | 25 | |
WT-BCT-0.69-40-3 | 202*102*230 | M8 | 267 | 33 | |
WT-BCT-0.85-30-3 | 202*102*165 | M8 | 132 | 20 | |
WT-BCT-0.85-40-3 | 202*102*230 | M8 | 176 | 27 | |
WT-BCT-0.95-30-3 | 202*102*165 | M8 | 106 | 18 | |
WT-BCT-0.95-40-3 | 202*102*230 | M8 | 141 | 24 |
FILTER TYPE | |||||
Product name | Specification and model | Dimension(mm) diameter * height Width * depth * height | Terminal block | Rated capacity (uF) | Rated current (A) |
Cylindrical capacitor | WT-LCY-0.48-15-3 | D86*H245 | M6 | 207 | 17 |
WT-LCY-0.48-20-3 | D96*H290 | M6 | 276 | 24 | |
WT-LCY-0.48-25-3 | D106*H290 | M8 | 345 | 30 | |
WT-LCY-0.48-30-3 | D116*H290 | M8 | 414 | 36 | |
WT-LCY-0.48-40-3 | D136*H290 | M8 | 553 | 48 | |
Aluminum stretch capacitor | WT-LCT-0.45-15-3 | 175*62*160 | M6 | 236 | 19 |
WT-LCT-0.45-20-3 | 175*62*223 | M6 | 314 | 26 | |
WT-LCT-0.45-25-3 | 202*102*165 | M6 | 393 | 33 | |
WT-LCT-0.45-30-3 | 202*102*165 | M8 | 472 | 38 | |
WT-LCT-0.45-40-3 | 202*102*230 | M8 | 629 | 51 | |
WT-LCT-0.48-15-3 | 175*62*223 | M6 | 207 | 17 | |
WT-LCT-0.48-20-3 | 202*102*165 | M6 | 276 | 24 | |
WT-LCT-0.48-25-3 | 202*102*165 | M6 | 345 | 30 | |
WT-LCT-0.48-30-3 | 202*102*230 | M8 | 414 | 36 | |
WT-LCT-0.525-15-3 | 175*62*223 | M6 | 173 | 16 | |
WT-LCT-0.525-20-3 | 202*102*165 | M6 | 231 | 22 | |
WT-LCT-0.525-25-3 | 202*102*230 | M8 | 289 | 27 | |
WT-LCT-0.525-30-3 | 202*102*230 | M8 | 346 | 33 | |
WT-LCT-0.6-30-3 | 202*102*230 | M8 | 265 | 29 | |
WT-LCT-0.6-40-3 | 202*102*230 | M8 | 354 | 38 | |
WT-LCT-0.69-30-3 | 202*102*230 | M8 | 201 | 25 | |
WT-LCT-0.69-40-3 | 202*102*230 | M8 | 267 | 33 | |
WT-LCT-0.85-30-3 | 202*102*230 | M8 | 132 | 20 | |
WT-LCT-0.85-40-3 | 202*102*230 | M8 | 176 | 27 | |
WT-LCT-0.95-30-3 | 202*102*230 | M8 | 106 | 18 | |
WT-LCT-0.95-40-3 | 202*102*230 | M8 | 141 | 24 | |
Iron shell capacitor | WT-LCT-0.69-50-3 | 255*145*250 | M12 | 334 | 42 |
WT-LCT-0.69-60-3 | 255*145*300 | M12 | 401 | 50 | |
WT-LCT-0.69-80-3 | 255*145*400 | M12 | 535 | 67 | |
WT-LCT-0.69-100-3 | 255*145*450 | M12 | 669 | 84 | |
WT-LCT-0.69-120-3 | 255*145*500 | M12 | 802 | 100 | |
WT-LCT-0.95-50-3 | 255*145*250 | M12 | 176 | 30 | |
WT-LCT-0.95-60-3 | 255*145*300 | M12 | 212 | 36 | |
WT-LCT-0.95-80-3 | 255*145*400 | M12 | 282 | 49 | |
WT-LCT-0.95-100-3 | 255*145*450 | M12 | 353 | 61 | |
WT-LCT-0.95-120-3 | 255*145*500 | M12 | 423 | 73 |
TECHNICAL PARAMETER:
a) Volume deviation: (UF%) - 5 ~ 10%
b) Loss tangent (Tan δ): 0.01% (UN 50 Hz, 20 ºC)
c) Frequency: 50 Hz / 60 Hz
d) Ambient temperature: upper limit + 55 ºC, lower limit - 30 ºC
e) Maximum allowable voltage: 1.1un (for gap use, no more than 8 hours per day)
f) Maximum over current: 1.8in, long-term operation, transition current no more than 2.5in
g) Surge current withstand capacity: ≥ 200 * in
h) Insulation withstand voltage: 3KV / 10s
i) Loss: less than 0.25w/kvar (including the loss of external discharge device)
j) The capacitor is of oil immersed type (or nitrogen filled dry type), with over-current, over-voltage, over temperature and pressure fusing and explosion-proof function. Polypropylene film is used as dielectric inside, with self-healing function.
k) The capacitor has built-in discharge resistance, and the residual voltage between terminals drops below 50V within 1 minute after the power supply is cut off.
CONDITIONS OF USE:
1.The altitude shall not exceed 2500 m;
2.The ambient temperature is - 20 ºC - + 55 ºC, the average temperature is not higher than + 35 ºC within 24 hours;
3.relative humidity: no more than 90%;
4.There is no corrosive gas, conductive dust and flammable and explosive media in the surrounding environment;
5.The seismic intensity shall not exceed grade 8;
6.For indoor installation, there should be good ventilation conditions around. If it is installed in the cabinet, there should be exhaust facilities.