GYXTW53 Outdoor Dust Cable with Durable Black PE Jacket

Price $120.00 Compare
Min Order 10 KM
Shipping From Zhejiang, China
Popularity 246 people viewed
Quantity
+-
 

Ningbo Weiyi Intelligence Technology Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
GYXTW53
Communication
Single-mode Fiber
OEM
Round Wire
100(N/100mm)<1000(N/100mm)
1000N<10000N
1~48
CE, ISO9001
OEM
PE
300km for 14days
More Than 10km Can Be Designed by Customer
No
Exporting Drum
INGO
Drum
3KM
China
8544700000
Product Description
Description of GYXTW53


2. Cable Specification
2.1Color code
The tube color is nature. And fiber color in the tube starts from No. 1 Blue.
No.123456
ColorBlueOrangeGreenBrownGrayWhite
No.789101112
ColorRedBlackYellowPurplePinkAqua
Note: S100 means interval 100mm black circle.
2.2 Cable structure and parameter
SNItemUnitValue
1No. of fiberscount8
2Tube diameter(±5%)mm2.0
3Tube per coresFibers8
4Strength member mm0.8
5Cable diameter(±5%)mm11.5
6Out Jacket thicknessMm1.8
7Inner Jacket thicknessMM0.6
8Cable weight(±10%)kg/km120
Note: Mechanical sizes are nominal values.
3. Characteristic of Optical Cable
3.1 Min. bending radius for installation
Static:  10 x cable diameter
Dynamic:  20 x cable diameter
3.2 Application temperature range
Operation:  - 40ºC ~ +60ºC
Installation:  -20ºC ~ +50ºC
Storage/transportation:  - 40ºC ~ +70ºC
3.3 Main mechanical & environmental performance test
ItemTest MethodAcceptance Condition
Tensile Strength
IEC 794-1-2-E1
- Load: Short term tension
- Length of cable: about 50m
- Fiber strain £ 0.6%
- No fiber break and no sheath damage.
Crush Test
IEC 60794-1-2-E3
- Load: Short term crush
- Load time: 1min
- Loss change £ 0.1dB@1550nm
- No fiber break and no sheath damage.
Impact Test
IEC 60794-1-2-E4
- Points of impact: 3
- Times of per point: 1
- Impact energy: 1J
- Loss change £ 0.1dB@1550nm
- No fiber break and no sheath damage.
Repeated Bending
IEC 60794-1-2-E6
- Bending radius: 20 x OD
- No. of cycle: 30
- Loss change £ 0.1dB@1550nm
- No fiber break and no sheath damage.
Torsion
IEC 60794-1-2-E7
- Length: 1m
- Twist angle: ±180°
- No. of cycle: 10
- Loss change £ 0.1dB@1550nm
- No fiber break and no sheath damage.
Compound flow
IEC 60794-1-2-E14
- Length: 30cm
- Temperature:70 oC±2 oC
- Period:24h
- No outflow or dripping
Temperature Cycling
IEC 60794-1-2-F1
- Temperature:+20oC→-40oC→+60oC →+20oC
- Time of each step: 12h
- Number of cycle: 2
- Loss change £ 0.1dB/km@1550nm
- No fiber break and no sheath damage.





Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA