PM-8000C
Physiological Functions of Diagnosis and Monitoring Equipment
Patient Monitor
CE, ISO13485
All
12.1 Inch High Resolution Color TFT LCD Display
ECG, 2-Temp, NIBP, SpO2, Resp, Pr/Hr
12 Months
Oscillometry
Manual/Auto/Continuous
Adjustable
10-270mmhg
20-254bpm
±3bpm
Audo
Carton
CE, ISO
Jiangsu, China
9018193010
Product Description
Portable 12.1 Inch Multi-Parameter Patient Monitor with 6 Standard Parameters

Patient monitor is a kind of instrument or system which is used to measure and control patients physiological parameters, which can be compared with known settings, if they are higher than know settings, the system will alarm.

Patient monitor is a kind of instrument or system which is used to measure and control patients physiological parameters, which can be compared with known settings, if they are higher than know settings, the system will alarm.
Features:
6 Standard parameters: ECG, 2-TEMP, NIBP, SpO2, RESP, PR/HR
12.1 inch high resolution color TFT LCD display
Real time S-T segment analysis, pace-maker detection
Indication of incorrect manipulation and malfunction analysis
Patient info input management function
Muti-lead ECG waveforms display in phase
Large volume of tabular and praphic trends information storage and easy to recall
Capture dynamic waveforms
Up to 2 hours working capacity of built-in rechargeable lithium battery
Unique accessory management cabinet
Networking capacity
Optional: ETCO2, thermal printer ,built-in recorder, cart, wall shelf
Parameters:
NIBP | Method: Oscillometry Modes: Manual/Auto/Continuous Auto measure time: Adjustable Measurement range:10-270mmHg |
ECG | Lead mode: 3-lead or 5-lead Lead selection: I;II;III,avR;avL;avF Heart rate range: Adult:15-300bpm;Pediatric/Neonatal:15-300bpm ECG waveform: 2 channels Accuracy: ±1 bpm or ±1%,which is greater S-T segment detection; measurement range: -2.0mv~+2.0mv Alarm: Yes, audible and visual alarm, alarm events review |
SPO2 | Measurement range:0-100% Accuracy:70-100%,±2%,0-69%,upspecified Auto measure time: Adjustable |
Pulse Rate | Range:20-254bpm Accuracy: ±3bpm |
Respiration | Method: RA-LL impedance Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm Apnea alarm: Yes |
Temperature | Range:0-500 Accuracy: ± 0.10 Channel: Dual-channel |
Main unit | ECG cable Spo2 probe TEM Probe NIBP Tube Adult cuff Power cable Battery User manual ECG Electrodes |
Warranty period: | 1year for whole machine, half a year for parts |
MOQ | 1 unit |
Delivery time | Within 7 working days upon receipt the payment |
Terms of payment | T/T, L/C, western union |