Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent

Price $8000.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 400 people viewed
Quantity
+-
 

Nanjing Audo Medical Equipment Co., Ltd.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
BA-401
Biochemical Apparatus
Fully-Auto Chemistry Analyzer
CE, ISO13485
All
12 Months
Linear, Non-Linear, Multi Point, K Fa
Halogen Lamp
0.0001A
English, French, Spanish, German, Russian
Within 7 Days
80
80 Positions
220V or 110V, 50~60Hz
Fully Automatic, Random Access, Discrete
80 Assay
Audo
Carton
CE, ISO
Jiangsu, China
Product Description
BA-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent


 

Product name: Fully-auto biochemistry analyzer

Item No.: BA-401

Application:

Biochemistry Analyzer is designed for hospital or clinical laboratory to measure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

 

 Technical Specifications: 

Model

BA-401

Analytical System

Fully automatic, Random Access, Discrete

Method

End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank, etc

Assay Item

80 assay

 

ISE mould(K+, Na+, Cl-, Ca2+) available on request

Throughput

1 Reagent

400 tests/hr

 

2 Reagent

400 tests/hr

 

With ISE

120 tests/hr

Test Menu

T.BILI        r-GT/GGT   CHO   Ca     APOB-1/B   CHE

 

D.BILI       ALP/AKP    TG     CL     APOB      CREA

 

TP          UREA       CK     P      CK-MB     Mg

 

ALB         CREA       LDH   C       ASO       AFU

 

Lactic Acid   ALT/GPT     UA   α-HBDH  CO2        FMN

 

LP(a)        AST/GOT    GLU   AMY     LDL-C     HDL-C

 

CHE         LA          TBA   ADA     HS-CRP   PA

 

Fe           Cu          Zn    C3      C4         IgG

 

IgM          IgA          and drug, toxicity,etc.

Sample Position

80

 

Including standard, control and STAT; either serum cup or primary tube available

Sample Volume

1~100ul, 0.1ul/step

Reagent Position

2X40

Reagent Volume

R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step

Reagent/Sample Probe

With liquid level sensor, collision sensor, Teflon coating and automatic washing station

Reaction Time

0~999 seconds

Cuvette

High quality uv-transmitted plastic cuvette.

Cuvette Washing

8 channels automatic washing system for reaction cuvettes

Probe and Mixer Washing

Independent washing station for each sample/reagent probe and mixer

Alarm

Automatic alarm for malfunction (eg: collision, reagent/sample insufficiency, full waste container, etc)

Calibration

Linear, Non-linear, Multi standard, K factor

Sample Dilution/Retest

Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function

Wavelength

340-810nm

Light Source

Halogen lamp

Absorbance Resolution

0.0001A

Absorbance Accuracy

±0.0003A(0-2.5A)

Repeatability

±2%

Quality Control

Levy jennings quality control program at 3 levels

Barcode

Optional

Printer

Multiple report formats available

System

Windows XP; Windows 7

Power Supply

220V or 110V, 50~60Hz

Dimension

100×85×75(cm)

Weight

135kg

Features: 

l Random access fully automatic biochemistry analyzer

l New concept and more friendly software

l Automatic washing station for both sample and reagent probe

l Liquid level detection and collision protection for both sample and reagent probe

l Reliable cooling system for reagent chamber, condensate cooling design and peltier cooling system double ensure the cooling effect.

l Powerful reaction cuvette washing system

l ISE Unit & barcode scanner (optional)

l Lower waste and pro-environment

 

Structure:

1. Optical System

Light source: Halogen-tungsten lamp, 2000hours working life about

Wavelength: 340nm-810nm

Linear range:0~3ABS

2. Sample System

a) Sample tray: 80 sample position, available to use serum cup or blood tube

b) Sample volume:1~100ul, programmed by 0.1ul step

c) Sample probe: Liquid level detection and collision protection automatically

d) Probe cleaning: automatic washing both inside and outside, Carryover<0.1%

e) Automatic sample dilution

3. Reagent System

a) Reagent tray: 80 positions for single &dual Reagents.

b) Refrigeration: Refrigerated reagent

c) Compartment 24h Cooling system maintaining temperature 2~8°C

d) Reagent volume:1~400ul, programmed by 0.1ul step

e) Reagent probe: Liquid level detection and collision protection automatically

f) Pre-heating function.

g) Real-time monitoring of reagent volume and auto alarm

h) Probe cleaning: automatic washing both inside and outside, Carry over<0.1%

4. Reaction System

a) Reaction tray: 90 reaction cuvettes, High quality UV-transmitted plastic cuvettes adopt, flat design to ensure heating evenly

b) Back-Dividing-Light technology

c) Min Reaction volume: 180ul

d) Reaction Temperature:37°C+0.1°C

e) Mixing system: Independent mixing probe

f) Automatic washing cuvettes

5. Washing System

a) Automatic cleaning Sample/mixer probe 

b) Five channels washing station for each cuvette

c) Automatic record and deduct cuvette blank value

6. Operation Unit

Operation system: Windows XP or WIN 7

Interface: RS-232

7. Working Conditions

a) Power Supply: 220V±10%, 50/60HZ; 110V (optional)

b) Power consumption: ≤1200VA

c) Temperature:15~30°C

d) Humidity: ≤85%

e) Water consumption: 10L/h
 

Advantage of Our Company

1. Professional medical products manufacturer

2. High quality with competitive price

3. Independent Design and Outstanding Sales Team

4. Large Supply Ability

5. Excellent after-Sales service

 
Shipping & Packing:

Hospital Auto Clinical Chemistry Analyzer (DS161)   Hospital Auto Clinical Chemistry Analyzer (DS161)
 


Contact us:



Message Type
* Message Content
* Name  
* Phone
* Email