Contec ECG600g ECG Machine ECG Monitor Digital 6 Channel Electrocardiograph

Price $500.00 Compare
Min Order 1 Piece
Shipping From Hebei, China
Popularity 340 people viewed
Quantity
+-
 

Contec Medical Systems Co., Ltd.

VIP   Audited Supplier 18 years
Profile Certified by SGS/BV
ECG
Physiological Functions of Diagnosis and Monitoring Equipment
ECG
CE, ISO13485
Middle-aged and Old
Contec CE Approved Digital 3/6 Channel ECG Machine
3/6 Selectable
7" TFT-LCD
18 Months for Main Unit
CONTEC
Carton
CE
Hebei, China
9018110000
Product Description
ECG600g Ce Six Channel ECG Machine Digital ECG Monitor Contec Electrocardiograph

Product Description



CONTEC CE approved Digital 3/6 (SIX) Channel ECG Machine 
samples 12 leads ECG signals simultaneously and prints out the ECG waveforms with thermal printing system.This ECG machine with 7" TFT-LCD Touch screen(touch screen and Function keys)


Function:
1.Recording and displaying ECG waveform in AUTO/Manual mode
2.Measuring and diagnosing ECG waveform parameters automatically,
3.Prompting for "Lead off" and "Lack of paper",
4.Multi-language interface(Chinese, English, French, Spanish, Turkish, Polish, Italian, German, Portuguese, Kazakstan, Russian and Ukrainian), case database management.


Main Performance
Screen7" TFT-LCD
Input modefloating and defibrillation protection
Paper size80mm(W)×20m(L)
CMRR>60dB, >100dB(add filter)
Time constant≥ 3.2s
Frequency response0.05Hz ~ 150Hz(-3dB~+0.4dB)
Patient leak current<10µA
Calibration voltage1mV
Sensitivity2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level<15µVp-p
Input circuit current≤50nA
Input impedance≥50MΩ
Sampling accuracy12-bit
Safety classificationclass I, type CF and defibrillation-proof applied part
Recording modethermal printing system
Auto recordset record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm recordset record according to rhythm record format and mode, automatically measuring and analyzing.
Manual recordset record according to record format, manually switching leads.
Measurement parametersHR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Sampling frequency1000Hz
EMG interference filter25Hz/35Hz (-3dB)
Power frequency filterAC 50Hz/60Hz(-20dB)
Paper speed:Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
 