Factory Price Vb2 Plus-17.5/T1250-31.5 Aeg Vcb Vacuum Circuit Breaker

Price $720.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 496 people viewed
Quantity
+-
 

Shengsu Electric Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
ZN63-12
High Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
Vacuum
Fixed
Vcb
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
ISO9001-2000
12kv
Withdrawable
630A/1250A/1600A/2000A
50/60Hz
Steel, Expoxy Resin
Yes
Zn63-12
Medium
150mm/210mm
White/Red
10000times
4s
-15-40
≤1000m
Not Exceed 8 Degrees
SHENGSU ELECTRIC CO., LTD
Wooden Case
pcs
China
Product Description
Place of Origin:Wenzhou Zhejiang China
Brand Name: SHENGSU
Model Number: VS1-12
Rated frequency: 50 Hz
Mechanical life: 10000 times
Material: Stainless steel
Rated current: 630A
VS1 (ZN63A) - 12 indoor high voltage vacuum circuit breaker, three-phase ac 50 hz, rated voltage of 12 kv power system of indoor switchgear, as power equipment, industrial and mining enterprises, power protection and control unit. Apply to working in the rated electric demand flow frequent operation, or more open circuit short circuit current.
The circuit breaker operating mechanism and circuit breaker unibody design of ontology. Can be used as the fixed installation leather yuan, also can equipped with feed mechanism, form a handcart unit.
 
Product Parameters
 
Rated voltage kV1224

Rated insulation level
Power frequency withstand voltage (1min)kV42/4865/79
Lighting impulse withstand voltage (peak)kV75/85125/145
Rated current A630-4000630-3150
Rated short-time withstand current kA25-4025-40
Rated peak withstand current kV63-10063-100
Rated short-circuit breaking current kA25-4025-40
Rated short-circuit making current kA63-10063-100
Rated frequency Hz5050
Secondary circuit rated short-time withstand voltage(1min) kV22
Secondary circuit rated voltage VDC110,220 / AC110,220DC110,220 / AC110,220
 

Using the environment conditions

Ambient air humidity: cap + 40 ºC, lower limit - 15 ° ºC
Altitude: < 1000 m (if need higher elevation, the rated insulation level increase)
Needs: amplitude, intensity of no more than 8 degrees
Air relative humidity, average no greater than 95%, the monthly average no greater than 90%
No fire and explosion danger, serious pollution, chemical corrosion and the site of violent vibration