Metering Unit 11kv High Voltage Dry Type Current Oil Type Transformer Combiners

Price $2150.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 336 people viewed
Quantity
+-
 

Shengsu Electric Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
JLS-10
Instrument
Combined Transformer
Three
Outdoor
Measurement
11kv
Withdrawable
50/60Hz
Resin
Medium
630A
35kv/100V
Yes
Jls-35
Shengsu
-25-40
≤1000m
Cos=0.8(Lagging)
Wenzhou Zhejiang China
ISO9001-2008
SHENGSU ELECTRIC CO., LTD
Cartoon
pcs
China
Product Description
Place of Origin:Wenzhou Zhejiang China
Brand Name:Shengsu
Model Number: JLS-35
Rated frequency: 50 Hz
Mechanical life: 10000 times
Material: Stainless steel
Rated current: 630A
This product is mainly composed of two parts of the combined transformer and the meter box, the combined transformer is composed of two or three single-phase voltage transformer and current transformer, with 25#transformer oil as the insulating medium, the first and second outlet end are installed on the panel witn porcelain bushing. The watt-hour meter box is mounted on the side of the combined transformer and consists of a walt-hour meter and a reactive walt-hour meter. It has the advantages of high measuring accuracy, light weight, convenient installation and anti-theft.
This series of electric energy metering box is suitable for outdoor rated voltage 6, 10, 35kV, rated frequency 50Hz three-phase system network.

 
Rated voltage kV1224

Rated insulation level
Power frequency withstand voltage (1min)kV42/4865/79
Lighting impulse withstand voltage (peak)kV75/85125/145
Rated current A630-4000630-3150
Rated short-time withstand current kA25-4025-40
Rated peak withstand current kV63-10063-100
Rated short-circuit breaking current kA25-4025-40
Rated short-circuit making current kA63-10063-100
Rated frequency Hz5050
Secondary circuit rated short-time withstand voltage(1min) kV22
Secondary circuit rated voltage VDC110,220 / AC110,220DC110,220 / AC110,220
 

Using the environment conditions


Ambient air humidity: cap + 40 ºC, lower limit - 15 ° ºC
Altitude: < 1000 m (if need higher elevation, the rated insulation level increase)
Needs: amplitude, intensity of no more than 8 degrees
Air relative humidity, average no greater than 95%, the monthly average no greater than 90%
No fire and explosion danger, serious pollution, chemical corrosion and the site of violent vibration