ICU Patient Monitor for Invasive

Price $665.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 244 people viewed
Quantity
+-
 

Guangzhou Jiuyuekang Medical Equipment Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
SNP8000
Physiological Functions of Diagnosis and Monitoring Equipment
Patient Monitor
CE, ISO13485
Adult and Children
8 Inches
JYK
Carton
CE, FDA
Guangdong, China
Product Description
Medical equipment, invasive patient monitor, ICU monitor,  measure artery monitor
medical monitor, hospital monitor , invasive monitor


MONITOR (for measure artery, invasive)
ICU Monitor

Multi-Para Patient monitor

8.4" Standard 6 Parameters
ECG, NIBP,SpO2,RESP, TEMP,HR/PR

Features &Benefits:
  1. 8" color TFT display, high resolution 800×600 dpi;
  2. Separated para board: ECG, NIBP, SpO2 board;
  3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
  4. Real time S-T segment analysis, and ARR analysis;
  5. SpO2 Pitch Tone Variation and Drug Dose Calculation;
  6. Parameter waveform and characters color selectable
  7. Multi and unique display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  8. Standby mode for Energy saving and suspend monitoring;
  9. 7-lead ECG waveforms display in phase;
  10. Capture dynamic waveforms;
  11. Built-in rechargeable lithium battery, and battery volume checking.
  12. Efficient resistance to interference of defibrillator and HF knife;
  13. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
  14. TCP/IP networking platform enable abundant future upgrade
  15. Complete and flexible mounting solution for transportation and in-patient monitoring

Standard parameters: 5-lead ECG, RESP, HR, NIBP, SPO2(F-5), 1-TEMP, PR;
Optional: Touch Screen, ,SD card,4-IBP,EtCO2, SpO2(F-6) /nellcor SpO2


Performance Specifications
Display:     8''color TFT
Rolling and refreshing waveform display
Resolution: 800×600
Multi display selectable including:
Large-font display
Trend coexist display
OxyCRG dynamic view display.
Bed-to-bed view display
Trace:          4 waveforms(2 ECG, 1 SPO2 and 1 RESP)
Sweep speed:6.25mm/s, 12.5mm/s,25mm/s,50mm/s
Indicator:       Power/battery indicator light
QRS beep and alarm sound
Battery:        Rechargeable lead acid cell, 12v/4AH
Max.24 hour for charging, 4 hours for continue working
Trend:            Parameter graphic and tabular trends:
5s/piece,8 hours;
1min/piece,168 hours(24hour×7days)
5min/piece,1000 hours.

Storage:          NIBP:1000 groups
Alarm:200 groups
Full disclosure waveforms: 3600S
Alarm:       User-adjustable High, Medium and Low limits 3-level Audible and visual alarm
Networking:     Connected to central monitoring system
TCP/IP netting platform
Recorder:      Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type:    Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record


Standard Parameter:
ECG:

Lead mode: 5 -lead(R,L,F,N,C)
Lead selection : I,II,III,avR,avL,avF,V
Waveform:    4 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 6.25 mm/s; 12.5mm/s;25mm/s;50mm/s
Heart rate range:    Adult: 15~300bpm; Neonate:/pediatric:15~350bpm
Accuracy: +1bpm or +1%,whichecer is greater
Resolution:    1bpm
Filter: surgery mode:1~20Hz
monitor model:0.5~40Hz
Diagnostic mode:0.05~130Hz
Scaling signal: 1mv,+3%
Protection:     withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detecton:
Measurement range:  2.0mV~+2.0mV                        
 
 Alarm Range:        -2.0mV~ +2.0mV
Accuracy:           -0.8mV ~+0.8Mv
Error:              +0.02Mv
 
Arrhythmia analysis: YES

SPO2
Measurement range:       0~100%
Resolution:               1%
Accuracy:                +2%(70-100%);0-69% unspecified
Alarm range              0~100%
Pluse Rate:               range:20~300bpm
Resolution:1bpm
Error:+1bpm or +2%,whichever is greater

NIBP
Method:                  Digital Automatic oscillometric
Operation mode :          Manual/Automatic/continuous
Auto measurement time:    Adjustable(1~480min)
Measurement Unit:        mmHg/Kpa selectable
Measurement types:        Systolic, Diastolic, Mean  
Measurement tange:
Range of Systolic pressure:   Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:    Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:   Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate :10~100mmHg
Over-pressure protection:    Double safety protection
Resolution:                1 mmHg
Alarm:                   Systolic.Diastolic,Mean


RESPIRATION
Method:                    Thoracic impedance
Measurement range:          Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm:                YES,10~40s
Resolution:                  1rpm
Accuracy:                   +2rpm


TEMPERATURE
Compatible probe:            YSI or CYF
Measurement range:          5~50ºC
Resolution :                  0.1ºC
Accuracy:                   +0.1ºC
Refreshing time:              about 1
Average measuring time:       <10s


Miscellaneous

Satety:            
Safety level: Class I, type CF

Operation Environment
Temperature:    Working 0~+40ºC
Transportation and storage -20~+60ºC
Humidity:       working≤85%
Transportation and storage≤93%
Power:         AC 100-240,50/60Hz
Patient range:   Neonate, pediatric, adult patients


Accessories supplies
(1) 5 lead ECG cable 
(2) 1 spo2 probes 
(3) 1 NIBP prbe  
(4) 1 temp probe
(5)1 ground connecting liner  
(6) Chest electrode (10pcs/set)