MST-YW-300
Whole Life Technical Support
Warranty Is 12 Months
J&X
Customized
Non Portable
O2
Oxygen O2, Carbon Dioxide CO2
Sample Gas Pressure Negative Pressure or Slightly
Trace; Moisture Content 10%-50%Vol
Compressed Air 0.7MPa, Nitrogen 0.6-1MPa; Purity 9
External, Normal Pressure or Negative Pressure Rec
Above 70ºC, Maximum Temperature 400ºC
: 4~20mA
Oxygen 0-21%Vol; Carbon Dioxide CO2 0-10%Vol
J&X
Wooden Case
600*600*1600mm
China
9031809090
Product Description
Online Gas Detector Oxygen and Carbon Dioxide Dual Meter Analyzer for Laboratory
I. General Principles
This solution is applicable to the online monitoring system of oxygen and carbon dioxide concentration in the environment of Party A's equipment. This system can sample and detect the concentration of oxygen and carbon dioxide gas in the production process in real time, and provide the detected gas content to the user in the form of 4-20mA current signal, which is used to realize automatic control and analysis of system process, etc.
II. On-site conditions
1. On-site power supply: 24VDC, 220VAC;
2. Sample gas components: oxygen O2, carbon dioxide CO2
3. Pressure: sample gas pressure negative pressure or slightly positive pressure less than 3KPA
4. Particles: trace; moisture content 10%-50%vol
5. Compressed gas source: compressed air 0.7MPa, nitrogen 0.6-1MPa; purity 99%
6. Exhaust: external, normal pressure or negative pressure recovery pipeline;
7. Operating temperature: above 70ºC, maximum temperature 400ºC;
8. Ambient temperature: normal temperature 20-40ºC.
Note: The above data is provided by the customer on site
III. On-site requirements:
1. Output signal: 4~20mA,
2. Detection limit: 0.1%, ±1%;
3. Detection range: oxygen 0-21%VOL; carbon dioxide CO2 0-10%VOL
4. Explosion-proof requirements: explosion-proof is not required;
5. Measurement purpose: to determine the oxygen and carbon dioxide concentrations in the environment of the equipment when it is turned on
6. Spare parts: standard;
I. General Principles
This solution is applicable to the online monitoring system of oxygen and carbon dioxide concentration in the environment of Party A's equipment. This system can sample and detect the concentration of oxygen and carbon dioxide gas in the production process in real time, and provide the detected gas content to the user in the form of 4-20mA current signal, which is used to realize automatic control and analysis of system process, etc.
II. On-site conditions
1. On-site power supply: 24VDC, 220VAC;
2. Sample gas components: oxygen O2, carbon dioxide CO2
3. Pressure: sample gas pressure negative pressure or slightly positive pressure less than 3KPA
4. Particles: trace; moisture content 10%-50%vol
5. Compressed gas source: compressed air 0.7MPa, nitrogen 0.6-1MPa; purity 99%
6. Exhaust: external, normal pressure or negative pressure recovery pipeline;
7. Operating temperature: above 70ºC, maximum temperature 400ºC;
8. Ambient temperature: normal temperature 20-40ºC.
Note: The above data is provided by the customer on site
III. On-site requirements:
1. Output signal: 4~20mA,
2. Detection limit: 0.1%, ±1%;
3. Detection range: oxygen 0-21%VOL; carbon dioxide CO2 0-10%VOL
4. Explosion-proof requirements: explosion-proof is not required;
5. Measurement purpose: to determine the oxygen and carbon dioxide concentrations in the environment of the equipment when it is turned on
6. Spare parts: standard;
Category | Parameters | Technical Specifications |
Working conditions of the whole system | Power supply voltage | 220VAC/24VDC, |
Air pressure | Above 0.5MPa, not exceeding 1MPa | |
Pipeline sampling port | 8mm quick-release jack 1 | |
Pretreatment box | ![]() | 600*600*1600, equipped with oxygen analyzer, carbon dioxide analyzer, and pretreatment components (see the pretreatment accessories list for details) |
Oxygen content analyzer Paramagnetic type | ![]() | Gas name: oxygen gas analyzer Detection gas: O2 Measurement range: 0-21%VOL Resolution: 0.1% Response time: T90<30S Output signal: 4-20mA Power supply voltage: 220VAC/24VDC, |
CO2 infrared analyzer | ![]() | Gas name: infrared analyzer Detection gas: CO2 Measurement range: 0-10%VOL Resolution: 0.1% Response time: T90<30S Output signal: 4-20mA Power supply voltage: 220VAC/24VDC, |