Online Gas Detector Oxygen and Carbon Dioxide Dual Meter Analyzer for Laboratory

Price $1000.00 Compare
Min Order 1 Set
Shipping From Chongqing, China
Popularity 499 people viewed
Quantity
+-
 

Chongqing Jiuxin Automation Technology Co., Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
MST-YW-300
Whole Life Technical Support
Warranty Is 12 Months
J&X
Customized
Non Portable
O2
Oxygen O2, Carbon Dioxide CO2
Sample Gas Pressure Negative Pressure or Slightly
Trace; Moisture Content 10%-50%Vol
Compressed Air 0.7MPa, Nitrogen 0.6-1MPa; Purity 9
External, Normal Pressure or Negative Pressure Rec
Above 70ºC, Maximum Temperature 400ºC
: 4~20mA
Oxygen 0-21%Vol; Carbon Dioxide CO2 0-10%Vol
J&X
Wooden Case
600*600*1600mm
China
9031809090
Product Description
Online Gas Detector Oxygen and Carbon Dioxide Dual Meter Analyzer for Laboratory


I. General Principles

This solution is applicable to the online monitoring system of oxygen and carbon dioxide concentration in the environment of Party A's equipment. This system can sample and detect the concentration of oxygen and carbon dioxide gas in the production process in real time, and provide the detected gas content to the user in the form of 4-20mA current signal, which is used to realize automatic control and analysis of system process, etc.


II. On-site conditions
1. On-site power supply: 24VDC, 220VAC;
2. Sample gas components: oxygen O2, carbon dioxide CO2
3. Pressure: sample gas pressure negative pressure or slightly positive pressure less than 3KPA
4. Particles: trace; moisture content 10%-50%vol
5. Compressed gas source: compressed air 0.7MPa, nitrogen 0.6-1MPa; purity 99%
6. Exhaust: external, normal pressure or negative pressure recovery pipeline;
7. Operating temperature: above 70ºC, maximum temperature 400ºC;
8. Ambient temperature: normal temperature 20-40ºC.
Note: The above data is provided by the customer on site


III. On-site requirements:
1. Output signal: 4~20mA,
2. Detection limit: 0.1%, ±1%;
3. Detection range: oxygen 0-21%VOL; carbon dioxide CO2 0-10%VOL
4. Explosion-proof requirements: explosion-proof is not required;
5. Measurement purpose: to determine the oxygen and carbon dioxide concentrations in the environment of the equipment when it is turned on
6. Spare parts: standard;
 
CategoryParametersTechnical Specifications
Working conditions of the whole systemPower supply voltage220VAC/24VDC,
Air pressure
 
Above 0.5MPa, not exceeding 1MPa
Pipeline sampling port8mm quick-release jack 1
Pretreatment box
 
 
 

 
600*600*1600, equipped with oxygen analyzer, carbon dioxide analyzer, and pretreatment components (see the pretreatment accessories list for details)
 
Oxygen content analyzer

Paramagnetic type
 
Gas name: oxygen gas analyzer
Detection gas: O2
Measurement range: 0-21%VOL
Resolution: 0.1%
Response time: T90<30S
Output signal: 4-20mA
Power supply voltage: 220VAC/24VDC,
 
CO2 infrared analyzer
 
Gas name: infrared analyzer
Detection gas: CO2
Measurement range: 0-10%VOL
Resolution: 0.1%
Response time: T90<30S
Output signal: 4-20mA
Power supply voltage: 220VAC/24VDC,
 


 
 