HSA1509-0507ZNH
12 Months
12 Months
Electronic Components Firing Furnace
CE, ISO
Horizontal Type
Hengli
31kw
0.3~0.5MPa
0.2~0.4MPa
+-1c
HENGLI
Wooden Box Iron Bracket
8000*1200*1350mm
China
8514390090
Product Description
Product Description
- Model HSA1509-0507ZNH belt type brazing furnace
- Technical Specification:
- Rated Temperature Range: 600ºC, Max. Temperature: 700ºC
- The effective height:90mm
- Belt width: 150mm
- Chamber: 6mm thick SUS316 muffle tube structure.
- Max. load on the belt: 50kg/m2(exclude the belt weight)
- Drive system: big wrap angle friction drive
- Belt speed: 50~300mm/min, stepless speed regulation control with frequency conversion. Typical work speed is 160-180mm/min
- Heating element: ceramic tube with high temperature resistance alloy wire
- Furnace atmosphere: Nitrogen+hydrogen
- Atmosphere control: 5 nitrogen + 3 hydrogen, each flow can be adjusted.(please see 3.2 for details)
- Oxygen Content Test Point: Four points (Nitrogen source, heating up zone, free cooling zone and cooling zone) are connected in parallel to oxygen analyzer. Testing switcher point can be chosen through magnetic valve. The oxygen content in the chamber can be real time detected and the gas inflow is easy to adjust & choose
- Oxygen Content(equipped with oxygen content analyzer for online testing)
Free cooling zone≤15ppm+ oxygen content from gas source
Water cooling zone≤20ppm+ oxygen content from gas source
- Exhaust System: entrance and exit Vestibule jacket have 1 exhaust stack(with ignition device) separately(please see no.3.2 for details)
- Cooling Mode: use gas cooling plus water cooling, water cooling jacket has 1 water temperature test point
- Belt cleaning: ultrasonic cleaning system
- The layout of furnace structure(please see no.3.1 for details)
- Control Accuracy: ±1ºC
- Temperature Uniformity: ±2.5ºC, (Flat-Temperature zone 400ºC).
- Zone Number:5 zones
- Temperature Control Point: 5 points
- Thermocouple: K type
- Alarm instructions: over temperature, thermocouple failure, low gas pressure, low water pressure, belt stop alarm, ignitor alarm and other audible and visual protection
- Power-off Protection: add manual operating device
- Stop Button: One emergency stop buttons at the entrance and exit of the furnace
- Atmosphere safety protection: the hydrogen inlet will be close automatice when any case happened such as power failure, low nitrogen gas pressure or ignitor failure.
- Nitrogen consumption: 10~12m3/h
- Nitrogen working pressure: 0.3~0.5MPa
- Hydrogen consumption: about 4~6m3/h
- Hydrogen working pressure: 0.2~0.4MPa
- The temperauter of furnace surface: <35ºC
- Discharge temperature at exit: <70ºC( at the belt speed≤160mm/min and the max temperature of products≤380ºC)
- Heating power: 31kW
- Insulation Power of Empty furnace: ≤11kW
- Power source: capacity>41KVA, 3 phases 4 wires, 415~440VAC, 50Hz, single phase 240V
- Weight: about 4000kg
- Overall dimension: 8000*1200*1350mm(L*W*H).(Exclude mounting feet and alarm lamp)
- Outside pannel use high temperature spraying coating and off-white color.
- General Description
- Furnace body design

Figure 1: Furnace layout drawing
Table 1 | |||
Code | Name | Length | Note |
A | Total length | 8000mm | |
B | Load and unload table | 600mm | |
C | Furnace frame | 6800mm | |
D | Entrance vestibule zone | 900mm | Include entrance curtain and muffle elongation |
E | Entrance insulation zone | 150mm | Ceramic fiber insulation |
F | Heating zone | 1800mm | 5 zones. Zone 1 and 2 are 450mm long with 8kw /zone . The rest zones are 300mm long with 5kw heating power for each. |
G | Cooling zone | 150mm | No heating elements, insulation material. |
H | Free cooling zone | 200mm | Gas inlet and test welding reserve place |
I | Water cooling zone | 3100mm | 2 segment water jacket, water flow from bottom to top, its flow can be adjusted, 1 point water temperature test. |
J | Exit transition zone | 500mm | Included air curtain |
K | Furnace height | 1350mm | Exclude the height of stack |
L | Equipment operation panel position |
- Atmosphere control system design

Figure 2: Gas layout drawing
Table 2 | ||
Code | Name | Explanation |
A | Entrance curtains | Nitrogen curtain, prevent outside air from entering the frunace. |
B | Exhaust | The manual valve on Venturi exhaust tube can be used for adjusting gas flow |
C | Heating up Gas(H2) inlet | Used for normal hydrogen supplement of heating zone |
D | High Temp Gas(H2) inlet | Used for hydrogen protection and normal hydrogen supplement of high temp zone. |
E | Free cooling gas(H2) inlet | Used for hydrogen protection and normal hydrogen supplement of cooling zone. |
F | Cooling gas(N2) inlet | Used for nitrogen protection and normal nitrogen supplement of cooling zone. |
G | Cooling gas(N2) inlet | Used for nitrogen supplement for cooling zone. |
H | Exit curtains | Nitrogen curtain, prevent outside air from entering the furnace. |
The actual gas flow of each pipe can be displayed by flowmeters. |
- The design of temperature control system
- Temperature measuring: use K type thermocouple independent measuring and control on the temperature control point of each zone.
- Temperature control: use of Shimaden Intelligent temperature controller to control, with PID parameter auto tuning, high temperature upper limit alarm, thermocouple failure and other protective alarm functions
- Heating Control System: for the heating control, grouped supply the electricity by 3 alternating current contactors to reduce the instantaneous current impact to the electric fence caused by the equipment.
- Control mode: solid state relay zero cross trigger mode.
- Over Temperature Alarm: when over temperature occurred in some zones, over temperature alarm system in corresponding zones immediately send audible and visual alarm signal and meanwhile the heating of this zone is cut off, the buzzer sounds alarm.
- Drive system design
- Drive Control uses the servo system to control the speed by gear box. The speed is adjustable continually.
- Belt conveyor device: to drive the driving and drived wheel through chain and sprocket wheel, and then generate the friction force by driving wheel and the belt drive the belt running. There is a belt deviation guide device on the both sides at the entrance and exit.
- Computer Control System
3.5.2 Friendly human-machine interface
3.5.3 Industrial computer can carry out multiple programs saving
3.5.4 Real-time temperature and alarm record, data saving and printing
3.5.5 Computer control system with automatic heating up function
3.5.6 It also can provide the temperature calibration function in the chamber for adjusting process requirement.