FCHA
Available
10 Years
Separator
Carbon Steel
>1000L
Jacket
Positive
N/a
Hot Water Heating
Jacketed
Automatic
New
3.0MPa
2.5MPa
3.2MPa
988kg
LUHAO
Container
1000L
China
84198990
Product Description
Vessel
Capacity m³: 1.0
Material: Q345R
Design pressure MPa: 3.0
Design temperature ºC: 120
Work pressure MPa: 2.5
Max work pressure MPa: 3.2
Work temperature ºC: 100
Medium: Chloromethane
Working life: 10 years
Jacket
Capacity m³: 0.27
Material: Q245R
Design pressure MPa: 0.5
Design temperature ºC: 120
Work pressure MPa: 0.35
Work temperature ºC: 100
Medium: hot water
Total weight Kg: 988
*For confidential reason, the drawing is in low definition. The drawing and technical parameters above are corresponding to the title. Other information and pictures may be uploaded to meet the platform's compulsory regulation in quantity and not necessariliy relevant to the title. If you have any question, please contact us for more information.








Capacity m³: 1.0
Material: Q345R
Design pressure MPa: 3.0
Design temperature ºC: 120
Work pressure MPa: 2.5
Max work pressure MPa: 3.2
Work temperature ºC: 100
Medium: Chloromethane
Working life: 10 years
Jacket
Capacity m³: 0.27
Material: Q245R
Design pressure MPa: 0.5
Design temperature ºC: 120
Work pressure MPa: 0.35
Work temperature ºC: 100
Medium: hot water
Total weight Kg: 988
*For confidential reason, the drawing is in low definition. The drawing and technical parameters above are corresponding to the title. Other information and pictures may be uploaded to meet the platform's compulsory regulation in quantity and not necessariliy relevant to the title. If you have any question, please contact us for more information.
MODEL | FCHA1000-2000L | FCHA3000-5000L | FCHA6000-8000L | FCHA10000-15000L | FCHA15000-25000L |
CAPACITY | 1000-2000L | 3000-5000L | 6000-8000L | 10000-1 5000L | 15000-25000L |
WORK PRESSURE MPa | -0.1-10.0 | -0.1-10.0 | -0.1-10.0 | -0.1-10.0 | -0.1 -8.0 |
WORK TEMPERATURE C° | -15-320 | -15-320 | -15-320 | -15-320 | -15-320 |
rpm | 0-320 | 0-320 | 0-320 | 0-320 | 0-320 |
DC motor power W | 3.0-11.0 | 11.0-22.0 | 15-37.0 | 22.0-55.0 | 37.0-75.0 |
Main materials | 09MnNiDR/16MnDR (low-temperature steel), 15CrMoR (high-temperature steel), stainless steel S30408/S32168/S31603, S39042, titanium material, duplex steel, shackle material, Hastelloy alloy, zirconium material, Monel, and other materials used for explosive composite plates. | ||||
Heating form | Jacket thermal oil, jacket steam, outer half pipe, inner coil pipe; Electric heating/flue gas heating (435ºC). | ||||
Mixing form | Disc turbine type, asymmetric turbine type, three blade impeller type, disc inclined blade, four wide blade, propulsion type, impeller type, anchor type, frame type, screw belt type, etc. | ||||
Shaft sealing form | Magnetic coupling drive with static sealing, zero leakage, long service life, simple installation, safe and environmentally friendly. | ||||
Remarks | Other special requirements, touch screen intelligent control, program control, and connection to DCS systems shall be designed, manufactured, and configured according to user needs. |








LUHAO Chemical Machinery Co. Ltd | ||||||||||||||
Pressure Vessel Design Information Collection Table | ||||||||||||||
Vessel | Jacket (Coil) | |||||||||||||
Work Medium | Name | |||||||||||||
Components | ||||||||||||||
Density (Kg/m³) | ||||||||||||||
Characteristics | ||||||||||||||
Viscosity (cP) | ||||||||||||||
Flow Velocity(m³/h) | ||||||||||||||
Design pressure (Mpa) | ||||||||||||||
Work pressure (Mpa) | ||||||||||||||
Design temperature(ºC) | ||||||||||||||
Work temperature (ºC) | ||||||||||||||
Wall temperature (ºC) | ||||||||||||||
Diamter (mm) | ||||||||||||||
Length (mm) | ||||||||||||||
Capacity(m³) | ||||||||||||||
Effective capacity (m³) | ||||||||||||||
Corrosion allowance (mm) | ||||||||||||||
Corrosion speed (mm/year) | ||||||||||||||
Recommended Materials | ||||||||||||||
Lowest value of average monthly temperature(ºC) | ||||||||||||||
Site location | ||||||||||||||
Installation condition | Indoor or Outdoor | |||||||||||||
Catalyst Volume(m³) | ||||||||||||||
Catalyst Density(Kg/m³) | ||||||||||||||
Heat Transfer Area() | ||||||||||||||
Coil Specification | ||||||||||||||
Basic Wind Pressure(Mpa) | ||||||||||||||
Seismic Basic Intensity | ||||||||||||||
Ambient Temperature(ºC) | ||||||||||||||
Site Type | ||||||||||||||
Operating Mode | ||||||||||||||
Insulation Materials | Name | |||||||||||||
Thickness | ||||||||||||||
Density (Kg/m³) | ||||||||||||||
Seal Requirements | ||||||||||||||
Liquid Level Gauge | ||||||||||||||
Emergency Cut-off | ||||||||||||||
Static Electricity Removal | ||||||||||||||
Anti Eddy Current Requirement for Liquid Outlet | ||||||||||||||
Installation and Mantainance Requirements | ||||||||||||||
Expected Useful Life (years) | ||||||||||||||
Safety accessories | Vessel | Jacket (Coil) | ||||||||||||
Location | ||||||||||||||
Type | ||||||||||||||
Specification | ||||||||||||||
Quantity | ||||||||||||||
Set pressure(Mpa) | ||||||||||||||
Burst disc | ||||||||||||||
Burst pressure(Mpa) | ||||||||||||||
Safety discharge(kg/h) | ||||||||||||||
Agitator | Type | |||||||||||||
Impeller Diameter(mm) | ||||||||||||||
Speed(r/min) | ||||||||||||||
Motor | Model | |||||||||||||
Power(kw) | ||||||||||||||
Explosion Proof Grade | ||||||||||||||
Speed reducer | ||||||||||||||
Piping Table | ||||||||||||||
No. | Dimension | Pressure | Connection Size Standard | Connection Surface Type | Function | |||||||||
a | ||||||||||||||
b | ||||||||||||||
c | ||||||||||||||
d | ||||||||||||||
e | ||||||||||||||
f | ||||||||||||||
g | ||||||||||||||
h | ||||||||||||||
j | ||||||||||||||
k | ||||||||||||||
Other Requirements if any |