Product Description

Visual electrophisiology
Model:RET-C
Main functions
GIMAmp - DC Amplifier for Visual Electrophysiology

24bit high resolution A/D, higher than competitor's 12/14 bit;
Optical isolated USB connection, powered by li-ion battery, totally isolated from AC power system, provide excellent anti-interference performance;
Automatically switched to USB power, when low battery;
Real time full digital filter, cut frequency & order for band bass, low pass, band stop, high pass, and comb filter can be independently set for each channel through software; Provide flexibility for your clinical handing and scientific research than ever;
2 channels by default, optional: 5 / 8 channels.
LightBurst® - Flash Stimulator

Small size, big energy;
Less than 3 Kg, test seated patient by default; Stimulator can also be taken down to test lying patient or infants; Test for dog, monkey, pig, mouse, rat, rabbit is also been supported conveniently;
18 groups of background, stimuli light source: white, red, blue, green and yellow; Optional: infra-red and ultra-violet for research purpose;
Small size leads to more efficient use of light energy, able to provide 100 cd·s/m2 white broad band stimuli in < 4ms, 10X ISCEV standard;
LCD Pattern Stimulator

Best configurability: checkerboard, horizontal/vertical stripes, rectangle stimuli; Reversal, on/off stimuli;
Fixation target and stimuli field can be adjusted;
Low-vision fixation target is available;
Hexagon & dartboard not available for RetiMINER-C.
TECHNICAL DATA
Amplifier | |
Input Impedience | ≥ 1000 MΩ |
CMRR | ≥ 115dB |
Input Noise | ≤ 4uVpp |
Filter | Full real time digital filter, band-pass, band-stop, high-pass, low-pass, comb filter apply to every channel independently |
A/D Resolution | 24 bit |
Port | Optical isolated USB 2.0 |
Power Supply | Li-ion battery, switch to USB power automatically when low battery |
Flash Stimulator | |
Light Source Color | White, Red, Green, Blue, Yellow and any of their combination |
Flash Luminance | Can produce 100cd·s/m2 broad-band white flash in < 4ms |
Flash Luminance Range | 0-1000 cd·s/m2 |
Stimuli Mode | Single, Double, String, On/Off, On duration can be adjusted |
Background Illumination | 0-3000 cd/m2 |
Stimuli Frequency | 0.01-200Hz |
Fixation & EOG | 11 Fixation/EOG indicator, 64 adjustable intensity; -25 - +25 EOG saccade range |
Monitor | Infra-red camera |
Pattern Stimulator | |
Luminance | 0-200 cd/m2 |
Contrast | > 98% |
Pattern Shape | Checkerboard, Horizontal/vertical stripes, rectangle, adjustable element angle |
Stimuli Mode | Reversal, On/Off, String |
Stimuli Field | Full field, left/right/upper/lower half, up-down/left-right margin; ¼ left-top/right-top/left-bottom/right-bottom; horizontal/vertical center, 1/8 center; Center circle with any angle; Field outside center circle with any angle. |
CASE EXAMPLE
VEP - depend on functional integrity of central vision at any level of the visual pathway including the eye, retina, the optic nerve, optic radiations, and occipital cortex;
ERG/FERG - mainly reflect function of rod/cone and connected bipolar cells, rod/cone system can be isolated through dark/light adaptation;
PERG - represent function of ganglion cells when photo-receptor & bipolar cells works fine;
EOG - is an electrophysiological test of function of the outer retina and retinal pigment epithelium (RPE).