4H2O2-5
Infrared Gas Sensor
Surface Type
Analog Type
Integration
Plastic
IP65
Medium
RoHS
Customized
3-Electrode Electrochemical
0~5 Ppm
<60 S
<±2% Signal
Linear
<2% Signal/Month
AERI
Packing Bottle
30 ml
China
4204960212
Product Description
4H2O2-5 Hydrogen Peroxide Electrochemical Sensor
(P/N: SEC-4H2O2-5)
(P/N: SEC-4H2O2-5)
Technical Specifications | |||
MEASUREMENT | |||
Operating Principle | 3-electrode electrochemical | ||
Detection Range | 0~5 ppm | ||
Sensitivity | 2000 ± 1000 nA /ppm | ||
Response Time (T90) | <60 s | ||
Repeatability | <±2% signal | ||
Linearity | Linear | ||
Long term output Drift | <2% signal/month | ||
ELECTRICAL | |||
Resolution | 0.05 ppm | ||
Recommended Load | 5~30 | ||
Bias Voltage | 300 mV | ||
0 mV | |||
ENVIRONMENTAL | |||
Operating Temp. Range | -20°C ~ 40°C | ||
Operating Humidity Range | 15% RH ~ 90% RH non-condensing | ||
Operating Pressure Range | 800 ~ 1200 mbar | ||
LIFETIME | |||
Recommended Storage Temp. | 0°C to +20°C in sealed container | ||
Expected Operating Life | 24 months in air | ||
Storage Life | 6 months in original packaging | ||
Standard Warranty | 18 months from date of dispatch |
Product Dimensions

All dimensions in millimeters (± 0.1mm)
Cross-sensitivity Data | ||
Gas | Concentration(ppm) | Output signal (ppm H2O2 equivalent) |
Carbon Monoxide | 20 | 0.3 |
Nitric Oxide | 20 | -0.5 |
Sulfur Dioxide | 2 | 1.5 |
Methane | 5000 | 0 |
SAFETY NOTE
Connection should be made via a PCB mounting socket. Soldering to pins will void the sensor's warranty.
It is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation;
As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own. The data is given for guidance only. It does not constitute a specification or an offer for sale