4C8H8-10
Electrochemical Gas Sensor
Surface Type
Analog Type
Integration
Plastic
IP65
Medium
RoHS
Customized
3-Electrode Electrochemical
0~100 Ppm
≤60s
<±2% Signal
Linear
<2% Signal/Month
AERI
Packing Bottle
30 ml
China
4204960212
Product Description
4C8H8-10 Styrene Electrochemical Sensor
(P/N: SEC-4C8H8-10)
(P/N: SEC-4C8H8-10)
Technical Specifications | ||
MEASUREMENT | ||
Operating Principle | 3-electrode electrochemical | |
Detection Range | 0~10 ppm | |
Sensitivity | 1000 ± 500 nA /ppm | |
Response Time (T90) | ≤50s | |
Repeatability | <±2% signal | |
Linearity | Linear | |
MEASUREMENT | <2% signal/month | |
ELECTRICAL | ||
Resolution | 0.1 ppm | |
Recommended Load | 5~30 | |
Bias Voltage | 300mV | |
ENVIRONMENTAL | ||
Operating Temp. Range | -20°C ~ 50°C | |
Operating Humidity Range | 15% RH ~ 90% RH non- condensing | |
Operating Pressure Range | 800 ~ 1200 mbar | |
LIFETIME | ||
Recommended Storage Temp. | 0°C to +20°C in sealed container | |
Expected Operating Life | 24 months in air | |
Storage Life | 6 months in original packaging | |
Standard Warranty | 12 months from date of despatch |
Product Dimensions

All dimensions in millimeters (± 0.1mm)
Cross-sensitivity Data | ||
Gas | Concentration(ppm) | Output signal (ppm C8H8 equivalent) |
Carbon monoxide | 5 | 5 |
Carbon dioxide | 5000 | 0 |
Methane | 3000 | 0 |
Chloromethane | 100 | 0 |
SAFETY NOTE:
Connection should be made via a PCB mounting socket. Soldering to pins will void the sensor's warranty.
It is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation;
If the Gas Sensor is removed from application circuit, a jumper should be added on 'R' and 'S' pin.
As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own. The data is given for guidance only. It does not constitute a specification or an offer for sale.