4hno3-20 Nitric Acid Electrochemica Sensor

Price $68.70 Compare
Min Order 1 Piece
Shipping From Hubei, China
Popularity 462 people viewed
Quantity
+-
 

HUBEI AERITECH CO., LTD.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
4HNO3-20
Electrochemical Gas Sensor
Surface Type
Analog Type
Integration
Plastic
IP65
Medium
RoHS
Customized
3-Electrode Electrochemical
0~20 Ppm
0.6 ± 0.15 μa /Ppm
<±2% Signal
Linear
<2% Signal/Month
AERI
Packing Bottle
30ml
China
4204960212
Product Description
4HNO3-20 Nitric acid Electrochemica Sensor 
(P/N: SEC-4HNO3-20)

 
 
Technical Specifications
MEASUREMENT 
Operating Principle3-electrode electrochemical
Detection Range0~20 ppm
Maximum Overload0.6 ± 0.15 μA /ppm
Sensitivity60 s
Response Time (T90)<±2% signal
RepeatabilityLinear
Linearity<2% signal/month

ELECTRICAL
Resolution0.1 ppm
Recommended Load5~30 
Bias Voltage0mV

ENVIRONMENTAL
Operating Temp. Range-20°C ~ 50°C
Operating Humidity Range15% RH ~ 90% RH non- condensing
Operating Pressure Range800 ~ 1200 mbar

LIFETIME
Recommended Storage Temp.0°C to +20°C in sealed container
Expected Operating Life24 months in air
Storage Life6 months in original packaging
Standard Warranty12 months from date of despatch

Product Dimensions

All dimensions in millimeters (± 0.1mm
 
Cross-sensitivity Data
GasConcentration(ppm)Output signal
(ppm HNO3 equivalent)
Carbon monoxide200 0
Nitric oxide300
Nitrogen dioxide1520
Carbon dioxide30000
Whilst the Gas Sensor are designed to be highly specific to the gas they are intended to measure, they will still respond to some degree to various gases. The table below is not exclusive and other gases not included in the table may still cause a sensor to react. The cross-sensitivity values quoted are based on tests conducted on a small number of sensors. They are intended to indicate sensor response to gases other than the target gas. Sensors may behave differently with changes in ambient conditions and any batch may show significant variation from the values quoted.
SAFETY NOTE:
Connection should be made via a PCB mounting socket. Soldering to pins will void the sensor's warranty.
It is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation;
As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own. The data is given for guidance only. It does not constitute a specification or an offer for sale.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA