5000m³ LNG Flat Bottom Storage Tank

Price $3000.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 407 people viewed
Quantity
+-
 

Suzhou Doer Gas & Chemical Equipment Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
1 Year
New
Customized
GB
Metal Tank
Liquid
LNG
Full Containment
15kpa or Customized
20 Years
Doer
Road, Sea or Railway
5000m³
China
8609001100
Product Description
Product Parameters
 Design code• "Design and Construction of Large Welded Low-Pressure Storage Tanks" (API 620),
• "Design and Manufacture of Site Built, Vertical, Cylindrical Flat-bottomed Steel Vessels for the Storage of Cryogenic Liquefied Gas" (GB/T26978-2021),
• "Storage Tank Systems for Refrigerated Liquefied Gas" (API 625)
• "Welded Tanks for Oil Storage" (API 650)
FunctionStorage Cryogenic liquid
TypeDouble layer metal wall
Storage MediumLNG
StructureFull containment
Insulation Typeperlite + elastic felt + cellular glass insulation block + glass wool
Design Pressure (MPa)25/-0.5kPa
Design TemperaturePrimary container-196ºC/50ºC
Secondary container-196ºC/50ºC
The Main MaterialPrimary containerS30408/SA-240 304
Secondary containerS30408/SA-240 304
Working Pressure15kPa or customized
Effective Volume5000
Static evaporation rate≤ 0.08% /d(LNG)
Design service life20 years
PaintingPrimer coat (Prefabricated)+ intermediate coat + topcoat (on-site)
ColorCustomized / Standard [white]
Mode of transportationRoad, Sea or Railway
Core ComponentsPrimary container, Secondary container, Thermal corner protect layer, Insulation system, Pipeline, Tower ladder & steel structure, Valves & Instruments, Firefighting system.
Technical Requirements
1.With high safety and sealing, it can ensure the safety of storage and prevent accidents, widely used in petrochemical and other fields. 
2.The primary and secondary container are both flat-bottomed and cylindrical metal storage tanks, and the primary container top is deck type. It is suspended from the vault support structure of the secondary container through a boom. The top of the secondary container is a spherical arch, and the top support structure is a ribbed ring grid. The foundation of the LNG storage tank adopts a concrete elevated pier structure.
3.The following are safety measures to prevent overpressure:
1)Recycle the evaporated gas from the tank via the BOG pipe; 
2)Discharge the gas from the tank to a low-pressure flare through the vent line; 
3) The exhalation relief valve actuates to vent gas from the tank to the low-pressure flare;
 
Company Profile
FAQ



Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA