KPH
Basic Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Low Noise Automation Type
AC Rotating Exciter
Ce ISO SGS Soncap TUV
380V/220V 400V/230V 415V/240V 480V/277V
50Hz/60Hz
220V/127V 230V/132V
Kanpor
Plywood&Plastic with Foam
diesel engine W/C alterantor with controller
Original of China
8502110000
Product Description
1MW 1MW 3MW 4MW 5MW 6MW 7MW 10MW HFO HEAVY FUEL OIL HFO GENERATOR SET Power Plant WITH Lloyd register LRQA of CSSC / MAN
/No. | /Item | /Q'ty | /specification | /Scope | |
CMP | Customer | ||||
1./Genset | |||||
1.1 | diesel engine | 3 | CMP-MAN 7L27/38 | ||
One (1) set of diesel engine including following items | |||||
1.1.1 | /Turbocharger | 1 | / With air inlet bend | ||
1.1.2 | /Charger Air Cooler | 1 | Fin and tube type | ||
1.1.3 | /Governor | 1 | |||
1.1.4 | /Flywheel | 1 | |||
1.1.5 | / Common base | 1 | |||
1.1.6 | / Turning device | 1 | /manual operating | ||
1.1.7 | / Starter | 1 | /Pneumatic | ||
1.1.8 | /Lub. oil cooler | 1 | /Plate type | ||
1.1.9 | /Duplex filter | 1 | |||
1.1.10 | /centrifugal by-pass filter | 1 | |||
1.1.11 | / pump for Lub.oil | 1 | /Engine driven | ||
1.1.12 | /Pre-lub. oil pump | 1 | /electrical pump | ||
1.1.13 | /Lub. oil thermostatic valve | 1set | /wax type | ||
1.1.14 | /HT water pump | 1 | /Engine driven | ||
1.1.15 | / HT thermostatic valve | 1set | /wax type | ||
1.1.16 | /Fuel oil leakage alarm | 1 | |||
1.1.17 | /duplex safety filter for fuel | 1 | |||
1.1.18 | /Resilient mountiung | /selected according to alculation | |||
1.1.19 | /flexible hoses for engine all connection | 1lot | |||
1.1.20 | Service platform | 1 | |||
1.2 /Generator | |||||
1.2 | /Generator | 3 | :2217.6kW/rating output from generator terminal is 2217.6kW , | ||
- /Capacity | 2772kVA / 750 rpm at ISO condition | ||||
- /No. of phase and wire | 3 phase / 4 wire / PF 0.8 | ||||
- /Voltage and frequency | 11V / 50 Hz | ||||
- Insulation Class/Temp.Rise | F/F | ||||
- /IP Class | IP23 | ||||
- /Electric system parts | /Maker's standard | ||||
/ One(1) set of Generator including following items ; | |||||
1.2.1 | /AVR | ||||
1.2.2 | / Space heater | ||||
1.2.3 | /Bearing sensor | ||||
1.2.4 | /Winding sensor | ||||
2. fuel oil system | |||||
2.1 | / HFO treatment process unit | 1 | xxxcSt/50ºC/design according toxxxcSt/50ºC HFO | ||
One (1) set of HFO treatment process unit including following items | |||||
2.1.1 | /HFO purifier unit | 1+1 | ,1500L/h /one use and the other reserve,effective separating amount approx850L/h | ||
2.2 | /Diesel oil supply process unit | 1 | |||
One (1) set of Diesel oil supply process unit including following items | |||||
2.2.1 | /Do supply pump | 1+1 | ,2.5m3/h/one use and the other reserve,rate of flow is approx2.5m3/h | ||
2.2.2 | /press. regulatuiong valve | 1 | |||
2.2.3 | /press. regulatuiong valve | 1 | |||
2.2.4 | / DO cooler | 1 | 15kW/approx 15kW | ||
2.3 | /HFO supply unit | 1 | xxxcSt/50ºC/design according toxxxcSt/50ºC HFO | ||
One (1) set of Diesel oil supply process unit including following items | |||||
2.3.1 | /HFO supply pump | 1+1 | ,1.2m3/h/one use and the other reserve,rate of flow is approx 1.2m3/h | ||
2.3.2 | /filter | 1 | |||
2.3.3 | /junction box | 1 | |||
2.3.4 | , base frame, support and pipe | 1lot | |||
2.4 | /HFO booster unit | 1 | xxxcSt/50ºC/design according toxxxcSt/50ºC HFO | ||
One (1) set of Diesel oil supply process unit including following items | |||||
2.4.1 | /auto back flushing filter | 1 | |||
2.4.2 | /return oil tank witth deaerating valve | 1 | |||
2.4.3 | /recycling oil pump | 1+1 | ,3.5m3/h/one use and the other reserve,rate of flow is approx 3.5m3/h | ||
2.4.4 | /heater | 1 | |||
2.4.5 | /viscosity control unit | 1 | |||
2.4.6 | /change-over valve for HFO /DO | 1 | |||
2.4.7 | ,,,/pipe, supprort,flange and base frame | 1 | |||
2.4.8 | / cooler | 1 | |||
2.4.9 | /press. regulatuiong valve | 1 | |||
2.5 | / fuel oil discharging process | ||||
2.5.1 | /leakage fuel oil collecting tank | 3 | 100L/approx 100L | ||
2.5.2 | /fuel oil drain pump | 3 | /pneumatic dredge pump | ||
3. Lubricating oil system | |||||
3.1 | /Lubricating oil treatment process | ||||
3.1.1 | / Lub. oil separator unit | 3 | ,760L/h/ steam heater,effective separating amount approx 230L/h | ||
3.2 | /lube pump system | 1 | |||
4. Cooling water system | |||||
4.1 | () Engine cooling water system(one-string system) | ||||
4.1.1 | /Expansion tank | 1 | 1.5m3/approx 1.5m3 | ||
4.1.2 | /LT water pump | 3 | /electrical driven | ||
4.1.3 | /air radiator | 3 | |||
4.1.4 | / Preheater Unit | 1 | |||
4.2 | /Cooling water supply system | ||||
4.2.1 | /Water treatment unit | 1 | |||
4.2.2 | /Water tank and perssurised system | 1 | |||
5. Compressed air system | |||||
5.1 | /air compressor | 1 | |||
/ One(1) set of air compressor unit including following items ; | |||||
5.1.1 | /air conpressor | 2 | 11/air conpressor one use and the other reserve | ||
5.1.2 | / comperssed air vessel | 2 | ,1.5m3/one use and the other reserve approx 1.5m3 | ||
5.1.3 | /Reduce pressure unit | 1 | 30bar8bar | ||
5.1.4 | /air dryer | 1 | |||
6. , Intake and exhaust gas system | |||||
6.1 | /Intake air system | ||||
6.1.1 | /Intake air filter | 3 | |||
6.1.2 | /Intake air silencer | 3 | |||
6.1.3 | /expansion joint forT/C inlet | 3 | |||
6.2 | /Exhaust gas system | ||||
6.2.1 | /exhaust gas silencer | 3 | |||
6.2.2 | /Expansion joint for T/C outlet | 3 | |||
6.2.3 | /Expansion joint for exhaust gas silencer in/out | 3 | |||
6.2.4 | /Exhaust gas stack | ||||
6.3 | /exhaust gas boiler system | ||||
6.3.1 | /Exhaust gas boiler | 3set | |||
6.3.2 | /Hot well tank | 1 | |||
6.3.3 | /Temp. control valve for Hot well tank | 1 | |||
6.3.4 | /condensator radiator | 1 | |||
6.3.5 | /steam distribution head | 1 | |||
6.3.6 | /Blow down tank | 1 | |||
6.3.7 | /feed water pump unit | 1set | 2,/every set include two pumps,one use and the other reserve | ||
6.3.8 | /chemical dosing unit | 1 | |||
7. Sludge oil treatment system | |||||
7.1 | /waste oil discharge pump | 1+1 | |||
7.2 | /engine room pit pump | 1+1 | |||
7.3 | /pump room pit pump | 1+1 | |||
8. Tank farm | |||||
8.1 | /tanks | ||||
8.1.1 | /HFO storage tank | 1 | 700M3 | ||
8.1.2 | / heater for HFO outlet the tank | 1 | |||
8.1.3 | 1 | 100m3 | |||
8.1.4 | /HFO service tank | 1 | 100m3 | ||
8.1.5 | /DO storage tank | 1 | 100m3 | ||
8.1.6 | /DO service tank | 1 | 100m3 | ||
8.1.7 | /New lub. oil storage tank | 1 | 100m3 | ||
8.1.8 | /Used lub. oil storage tank | 1 | 50m3 | ||
8.1.9 | /Oily Water Pond | 1 | |||
8.1.10 | /sludge tank | 1 | 50m3 | ||
8.2 | /Raw water supply system | ||||
9. Electrical System | |||||
9.1 | /Engine control cabinet | 3 | |||
9.2 | /outgoing cabinet | 1 | |||
9.3 | /insulate cabinet | 1 | |||
9.4 | /auxiliaries equipment cabinet | 3 | |||
9.5 | /Common auxiliaries equipment cabinet | 1 | |||
9.6 | /transform incoming cabinet | 1 | |||
9.7 | /transform outgoing cabinet | 1 | |||
9.8 | /plant transform | 1 | |||
9.9 | /PT cabinet | 1 | |||
9.10 | /Black start genset | 1 | |||
9.11 | /Black start engine cabinet | 1 | |||
9.12 | /central control | 1 | |||
9.14 | /DC system | 1 | |||
10. Spare parts | |||||
10.1 | /Engine spare parts | ||||
10.1.1 | /Standard spare parts for engine | 1set/plant | |||
10.1.2 | /commissioning spare parts for engine | 1set/plant | |||
10.2 | /Plant spare parts | ||||
10.2.1 | /spare parts for generator | 1set/plant | |||
10.2.2 | /spare parts for auxiliaries | 1set/plant | |||
10.3 | /engine tools | ||||
10.3.1 | /Standard tools for engine | 1set/plant | |||
10.4 | /plant tools | ||||
10.4.1 | /tools for mechnical equipment | 1set/plant | |||
10.4.2 | /tools for electrical panel | 1set/plant | |||
11. , piping and electrical material & work | |||||
11.1 | /Material | ||||
11.1.1 | /Materials for civil and foundation items | ||||
11.1.2 | /Materials for mechnical items | ||||
11.1.3 | /Materials for electrical items | ||||
11.2 | / guide installation work | ||||
11.2.1 | /installation/erection works for mechnical items | ||||
11.2.2 | /installation/erection waorks for electrical items | ||||
12. , civil & building material & work | |||||
12.1 | /civil work | ||||
12.1.1 | /site survey | ||||
12.1.2 | /site grading and leveling | ||||
12.1.3 | /Temporary faclity | ||||
12.1.4 | /road and paving | ||||
12.1.5 | /foundation and structure | ||||
12.1.6 | ,/Drainage and sewage work | ||||
12.1.7 | /fence and gate | ||||
12.2 | /building work | ||||
12.2.1 | /power house(engine hall) | ||||
12.2.2 | /power house (control room) | ||||
12.2.3 | /workhouse and warehouse | ||||
12.2.4 | /pump house | ||||
12.2.5 | /Administration bulilding | ||||
12.2.6 | / guard house | ||||
12.3 | /building service | ||||
12.3.1 | /sanitary system | ||||
12.3.2 | /overhead crane for power house | ||||
12.3.3 | /chain block hoist for pump house | ||||
12.4 | /fire detection and fighting system | ||||
13. /first filling and consumables | |||||
13.1 | /first filling of system | ||||
13.1.1 | /lube oil for genset | ||||
13.1.2 | /lube oil for black starter | ||||
13.1.3 | /chemicals for cooling and boiler water treatment | ||||
13.2 | /consumables for commissioning | ||||
13.2.1 | /Fuel | ||||
13.2.2 | /lube oil for genset | ||||
14. /engineering | |||||
14.1 | /system engineering | ||||
14.1.1 | /system engineering | ||||
14.2 | /mechnical engineering | ||||
14.2.1 | /equipment layout drawing in&out door | ||||
14.2.2 | /piping arrangement drawing | ||||
14.3 | /electrical engineering | ||||
14.3.1 | /electrical engineering for diesel power plant | ||||
14.3.2 | /power and electrical protect coordination engineering | ||||
14.4 | /civil engineering | ||||
15. /site activities | |||||
15.1 | /supervision | ||||
15.1.1 | /civil engineer for civil work | ||||
15.1.2 | /mech. engineer for installation | ||||
15.1.3 | /elec. Engineer for installation | ||||
15.2 | /commissioning | ||||
15.2.1 | ()/mech. Engineer for commissioning | ||||
15.2.2 | ()/elec. Engineer for commissioning | ||||
15.2.3 | (PLC)/PLC engineer for commissioning | ||||
15.2.4 | ()/Auxiliaries mech. Engineer for commissioning | ||||
15.2.5 | ()/Auxiliaries elec. Engineer for commissioning | ||||
15.3 | Extra required supervision, commissioning service by purchaser | ||||
16. /factory test and training service | |||||
16.1 | /shop test | ||||
16.1.1 | /engine and generator test at factory | ||||
16.1.2 | () | 3 | |||
16.2 | /training | ||||
16.2.1 | /training at site | ||||
17. /transportation | |||||
17.1 | /packing of equipment for transportation | ||||
17.1.1 | /packing of engine and aux.equipment | ||||
17.2 | /transportation of equipment | ||||
17.2.1 | /domestic transportation | ||||
17.2.2 | / transportation to local port | ||||
17.2.3 | /local transportation to site |
/No. | /Item | /Q'ty | /specification | /Scope | |
CMP | Customer | ||||
1./Genset | |||||
1.1 | diesel engine | 3 | CMP-MAN 7L27/38 | ||
One (1) set of diesel engine including following items | |||||
1.1.1 | /Turbocharger | 1 | / With air inlet bend | ||
1.1.2 | /Charger Air Cooler | 1 | Fin and tube type | ||
1.1.3 | /Governor | 1 | |||
1.1.4 | /Flywheel | 1 | |||
1.1.5 | / Common base | 1 | |||
1.1.6 | / Turning device | 1 | /manual operating | ||
1.1.7 | / Starter | 1 | /Pneumatic | ||
1.1.8 | /Lub. oil cooler | 1 | /Plate type | ||
1.1.9 | /Duplex filter | 1 | |||
1.1.10 | /centrifugal by-pass filter | 1 | |||
1.1.11 | / pump for Lub.oil | 1 | /Engine driven | ||
1.1.12 | /Pre-lub. oil pump | 1 | /electrical pump | ||
1.1.13 | /Lub. oil thermostatic valve | 1set | /wax type | ||
1.1.14 | /HT water pump | 1 | /Engine driven | ||
1.1.15 | / HT thermostatic valve | 1set | /wax type | ||
1.1.16 | /Fuel oil leakage alarm | 1 | |||
1.1.17 | /duplex safety filter for fuel | 1 | |||
1.1.18 | /Resilient mountiung | /selected according to alculation | |||
1.1.19 | /flexible hoses for engine all connection | 1lot | |||
1.1.20 | Service platform | 1 | |||
1.2 /Generator | |||||
1.2 | /Generator | 3 | :2217.6kW/rating output from generator terminal is 2217.6kW , | ||
- /Capacity | 2772kVA / 750 rpm at ISO condition | ||||
- /No. of phase and wire | 3 phase / 4 wire / PF 0.8 | ||||
- /Voltage and frequency | 11V / 50 Hz | ||||
- Insulation Class/Temp.Rise | F/F | ||||
- /IP Class | IP23 | ||||
- /Electric system parts | /Maker's standard | ||||
/ One(1) set of Generator including following items ; | |||||
1.2.1 | /AVR | ||||
1.2.2 | / Space heater | ||||
1.2.3 | /Bearing sensor | ||||
1.2.4 | /Winding sensor | ||||
2. fuel oil system | |||||
2.1 | / HFO treatment process unit | 1 | xxxcSt/50ºC/design according toxxxcSt/50ºC HFO | ||
One (1) set of HFO treatment process unit including following items | |||||
2.1.1 | /HFO purifier unit | 1+1 | ,1500L/h /one use and the other reserve,effective separating amount approx850L/h | ||
2.2 | /Diesel oil supply process unit | 1 | |||
One (1) set of Diesel oil supply process unit including following items | |||||
2.2.1 | /Do supply pump | 1+1 | ,2.5m3/h/one use and the other reserve,rate of flow is approx2.5m3/h | ||
2.2.2 | /press. regulatuiong valve | 1 | |||
2.2.3 | /press. regulatuiong valve | 1 | |||
2.2.4 | / DO cooler | 1 | 15kW/approx 15kW | ||
2.3 | /HFO supply unit | 1 | xxxcSt/50ºC/design according toxxxcSt/50ºC HFO | ||
One (1) set of Diesel oil supply process unit including following items | |||||
2.3.1 | /HFO supply pump | 1+1 | ,1.2m3/h/one use and the other reserve,rate of flow is approx 1.2m3/h | ||
2.3.2 | /filter | 1 | |||
2.3.3 | /junction box | 1 | |||
2.3.4 | , base frame, support and pipe | 1lot | |||
2.4 | /HFO booster unit | 1 | xxxcSt/50ºC/design according toxxxcSt/50ºC HFO | ||
One (1) set of Diesel oil supply process unit including following items | |||||
2.4.1 | /auto back flushing filter | 1 | |||
2.4.2 | /return oil tank witth deaerating valve | 1 | |||
2.4.3 | /recycling oil pump | 1+1 | ,3.5m3/h/one use and the other reserve,rate of flow is approx 3.5m3/h | ||
2.4.4 | /heater | 1 | |||
2.4.5 | /viscosity control unit | 1 | |||
2.4.6 | /change-over valve for HFO /DO | 1 | |||
2.4.7 | ,,,/pipe, supprort,flange and base frame | 1 | |||
2.4.8 | / cooler | 1 | |||
2.4.9 | /press. regulatuiong valve | 1 | |||
2.5 | / fuel oil discharging process | ||||
2.5.1 | /leakage fuel oil collecting tank | 3 | 100L/approx 100L | ||
2.5.2 | /fuel oil drain pump | 3 | /pneumatic dredge pump | ||
3. Lubricating oil system | |||||
3.1 | /Lubricating oil treatment process | ||||
3.1.1 | / Lub. oil separator unit | 3 | ,760L/h/ steam heater,effective separating amount approx 230L/h | ||
3.2 | /lube pump system | 1 | |||
4. Cooling water system | |||||
4.1 | () Engine cooling water system(one-string system) | ||||
4.1.1 | /Expansion tank | 1 | 1.5m3/approx 1.5m3 | ||
4.1.2 | /LT water pump | 3 | /electrical driven | ||
4.1.3 | /air radiator | 3 | |||
4.1.4 | / Preheater Unit | 1 | |||
4.2 | /Cooling water supply system | ||||
4.2.1 | /Water treatment unit | 1 | |||
4.2.2 | /Water tank and perssurised system | 1 | |||
5. Compressed air system | |||||
5.1 | /air compressor | 1 | |||
/ One(1) set of air compressor unit including following items ; | |||||
5.1.1 | /air conpressor | 2 | 11/air conpressor one use and the other reserve | ||
5.1.2 | / comperssed air vessel | 2 | ,1.5m3/one use and the other reserve approx 1.5m3 | ||
5.1.3 | /Reduce pressure unit | 1 | 30bar8bar | ||
5.1.4 | /air dryer | 1 | |||
6. , Intake and exhaust gas system | |||||
6.1 | /Intake air system | ||||
6.1.1 | /Intake air filter | 3 | |||
6.1.2 | /Intake air silencer | 3 | |||
6.1.3 | /expansion joint forT/C inlet | 3 | |||
6.2 | /Exhaust gas system | ||||
6.2.1 | /exhaust gas silencer | 3 | |||
6.2.2 | /Expansion joint for T/C outlet | 3 | |||
6.2.3 | /Expansion joint for exhaust gas silencer in/out | 3 | |||
6.2.4 | /Exhaust gas stack | ||||
6.3 | /exhaust gas boiler system | ||||
6.3.1 | /Exhaust gas boiler | 3set | |||
6.3.2 | /Hot well tank | 1 | |||
6.3.3 | /Temp. control valve for Hot well tank | 1 | |||
6.3.4 | /condensator radiator | 1 | |||
6.3.5 | /steam distribution head | 1 | |||
6.3.6 | /Blow down tank | 1 | |||
6.3.7 | /feed water pump unit | 1set | 2,/every set include two pumps,one use and the other reserve | ||
6.3.8 | /chemical dosing unit | 1 | |||
7. Sludge oil treatment system | |||||
7.1 | /waste oil discharge pump | 1+1 | |||
7.2 | /engine room pit pump | 1+1 | |||
7.3 | /pump room pit pump | 1+1 | |||
8. Tank farm | |||||
8.1 | /tanks | ||||
8.1.1 | /HFO storage tank | 1 | 700M3 | ||
8.1.2 | / heater for HFO outlet the tank | 1 | |||
8.1.3 | 1 | 100m3 | |||
8.1.4 | /HFO service tank | 1 | 100m3 | ||
8.1.5 | /DO storage tank | 1 | 100m3 | ||
8.1.6 | /DO service tank | 1 | 100m3 | ||
8.1.7 | /New lub. oil storage tank | 1 | 100m3 | ||
8.1.8 | /Used lub. oil storage tank | 1 | 50m3 | ||
8.1.9 | /Oily Water Pond | 1 | |||
8.1.10 | /sludge tank | 1 | 50m3 | ||
8.2 | /Raw water supply system | ||||
9. Electrical System | |||||
9.1 | /Engine control cabinet | 3 | |||
9.2 | /outgoing cabinet | 1 | |||
9.3 | /insulate cabinet | 1 | |||
9.4 | /auxiliaries equipment cabinet | 3 | |||
9.5 | /Common auxiliaries equipment cabinet | 1 | |||
9.6 | /transform incoming cabinet | 1 | |||
9.7 | /transform outgoing cabinet | 1 | |||
9.8 | /plant transform | 1 | |||
9.9 | /PT cabinet | 1 | |||
9.10 | /Black start genset | 1 | |||
9.11 | /Black start engine cabinet | 1 | |||
9.12 | /central control | 1 | |||
9.14 | /DC system | 1 | |||
10. Spare parts | |||||
10.1 | /Engine spare parts | ||||
10.1.1 | /Standard spare parts for engine | 1set/plant | |||
10.1.2 | /commissioning spare parts for engine | 1set/plant | |||
10.2 | /Plant spare parts | ||||
10.2.1 | /spare parts for generator | 1set/plant | |||
10.2.2 | /spare parts for auxiliaries | 1set/plant | |||
10.3 | /engine tools | ||||
10.3.1 | /Standard tools for engine | 1set/plant | |||
10.4 | /plant tools | ||||
10.4.1 | /tools for mechnical equipment | 1set/plant | |||
10.4.2 | /tools for electrical panel | 1set/plant | |||
11. , piping and electrical material & work | |||||
11.1 | /Material | ||||
11.1.1 | /Materials for civil and foundation items | ||||
11.1.2 | /Materials for mechnical items | ||||
11.1.3 | /Materials for electrical items | ||||
11.2 | / guide installation work | ||||
11.2.1 | /installation/erection works for mechnical items | ||||
11.2.2 | /installation/erection waorks for electrical items | ||||
12. , civil & building material & work | |||||
12.1 | /civil work | ||||
12.1.1 | /site survey | ||||
12.1.2 | /site grading and leveling | ||||
12.1.3 | /Temporary faclity | ||||
12.1.4 | /road and paving | ||||
12.1.5 | /foundation and structure | ||||
12.1.6 | ,/Drainage and sewage work | ||||
12.1.7 | /fence and gate | ||||
12.2 | /building work | ||||
12.2.1 | /power house(engine hall) | ||||
12.2.2 | /power house (control room) | ||||
12.2.3 | /workhouse and warehouse | ||||
12.2.4 | /pump house | ||||
12.2.5 | /Administration bulilding | ||||
12.2.6 | / guard house | ||||
12.3 | /building service | ||||
12.3.1 | /sanitary system | ||||
12.3.2 | /overhead crane for power house | ||||
12.3.3 | /chain block hoist for pump house | ||||
12.4 | /fire detection and fighting system | ||||
13. /first filling and consumables | |||||
13.1 | /first filling of system | ||||
13.1.1 | /lube oil for genset | ||||
13.1.2 | /lube oil for black starter | ||||
13.1.3 | /chemicals for cooling and boiler water treatment | ||||
13.2 | /consumables for commissioning | ||||
13.2.1 | /Fuel | ||||
13.2.2 | /lube oil for genset | ||||
14. /engineering | |||||
14.1 | /system engineering | ||||
14.1.1 | /system engineering | ||||
14.2 | /mechnical engineering | ||||
14.2.1 | /equipment layout drawing in&out door | ||||
14.2.2 | /piping arrangement drawing | ||||
14.3 | /electrical engineering | ||||
14.3.1 | /electrical engineering for diesel power plant | ||||
14.3.2 | /power and electrical protect coordination engineering | ||||
14.4 | /civil engineering | ||||
15. /site activities | |||||
15.1 | /supervision | ||||
15.1.1 | /civil engineer for civil work | ||||
15.1.2 | /mech. engineer for installation | ||||
15.1.3 | /elec. Engineer for installation | ||||
15.2 | /commissioning | ||||
15.2.1 | ()/mech. Engineer for commissioning | ||||
15.2.2 | ()/elec. Engineer for commissioning | ||||
15.2.3 | (PLC)/PLC engineer for commissioning | ||||
15.2.4 | ()/Auxiliaries mech. Engineer for commissioning | ||||
15.2.5 | ()/Auxiliaries elec. Engineer for commissioning | ||||
15.3 | Extra required supervision, commissioning service by purchaser | ||||
16. /factory test and training service | |||||
16.1 | /shop test | ||||
16.1.1 | /engine and generator test at factory | ||||
16.1.2 | () | 3 | |||
16.2 | /training | ||||
16.2.1 | /training at site | ||||
17. /transportation | |||||
17.1 | /packing of equipment for transportation | ||||
17.1.1 | /packing of engine and aux.equipment | ||||
17.2 | /transportation of equipment | ||||
17.2.1 | /domestic transportation | ||||
17.2.2 | / transportation to local port | ||||
17.2.3 | /local transportation to site |