BK-SL380-60
Oversea After Sales Team
Mouse Rat and Guinea-Pig Cage System
Incubation Equipment, Reproduction Apparatus
Mouse Rat and Guinea-Pig Cage
Electric
Air Duct
Medicated Bath Equipment
Curved Teeth
Non-Computerized
ISO9001:2008, CE
New
1 Year
SPF Ivc Mouse Rat Guinea-Pig Animal Experiment Cag
10~85 Times/H
0.1m/S
Level 5
55dB
0
10PA
110~220V, 50/60Hz
470*605*1550mm
570*705*1700mm
105kg
60
1346*500*1990mm
380*204*162mm
1446*600*2140mm
BIOBASE
Carton Package
1446*600*2140mm
Made in China
3926909090
Product Description
BIOBASE SPF IVC Mouse Rat Guinea-pig animal experiment Cage system




* IVC mouse cage system is composed of three parts: cage box, cage frame and main machine.
Main Machine
* PLC or MCU control, control, inlet and exhaust fans are well-known domestic brands, stable and reliable operation.
* With high-precision wind speed pressure difference sensor, temperature and humidity sensor.
* Built-in UPS, the fan continues working when the external power supply interrupted.
* With filter timing function to remind users to update the filter.
* With abnormal parameters alarm, filter life alarm, power failure alarm.
* Supporting remote monitoring through computer or mobile phone(PLC).
Cage Frame
* Cage frame material is SUS304 stainless steel.
* The gas pipe and the cage box are connected by a silicone gas nozzle. The inlet and exhaust vents of the cage box and cage frame adopt non-invasive structure.
* Inlet and exhaust duct can be disassembled for easy cleaning and disinfection.
* 4 inch PU wear-resistant universal wheel, no scratching PVC floor, flexible movement without noise. The arc angle structure prevents the damage of the during handling.
* The vertical and horizontal positions of the cage frame are numbered with letters such as A, B, C and numbers such as 1, 2, 3,which is convenient for experiment management.
* The cage guide rail is made of ABS engineering plastic, and with instructions for cage installation in place (if not in
place,there are light instructions to remind the operator).
* Cage frame material is SUS304 stainless steel.
* The gas pipe and the cage box are connected by a silicone gas nozzle. The inlet and exhaust vents of the cage box and cage frame adopt non-invasive structure.
* Inlet and exhaust duct can be disassembled for easy cleaning and disinfection.
* 4 inch PU wear-resistant universal wheel, no scratching PVC floor, flexible movement without noise. The arc angle structure prevents the damage of the during handling.
* The vertical and horizontal positions of the cage frame are numbered with letters such as A, B, C and numbers such as 1, 2, 3,which is convenient for experiment management.
* The cage guide rail is made of ABS engineering plastic, and with instructions for cage installation in place (if not in
place,there are light instructions to remind the operator).
* The cage box is composed of plastic base box, box cover, stainless steel mesh cover, drinking bottle and record card. The box cover has exhaust valve, silicone sealing circle and hasp.
* Base box and cover are molded by PPSU or PSU plastic. PPSU thermal deformation temperature>180ºC, steam sterilization for more than 500 times without deformation on condition that 205 kPa, 134°C, 5min. Thermal deformation temperature of PSU material>150ºC,steam sterilization over 200 times without deformation on condition that 205 kPa, 134°C, 5min.
* The cage box and 500ml drinking bottle are autoclavable.
* The box cover exhaust outlet is provided with a metal filter (25*50mm) to prevent the dust in the cage from being inhaled the cage frame and blocking the pipeline.
* The ventilated window is directly connected to the outside world, covered with 0.2µm high efficiency filter membrane, which can be directly washed and autoclavable.
* After the cage box is removed from the cage frame, the air inlet and exhaust valves of the cage box will automatically close immediately.
* Base box and cover are molded by PPSU or PSU plastic. PPSU thermal deformation temperature>180ºC, steam sterilization for more than 500 times without deformation on condition that 205 kPa, 134°C, 5min. Thermal deformation temperature of PSU material>150ºC,steam sterilization over 200 times without deformation on condition that 205 kPa, 134°C, 5min.
* The cage box and 500ml drinking bottle are autoclavable.
* The box cover exhaust outlet is provided with a metal filter (25*50mm) to prevent the dust in the cage from being inhaled the cage frame and blocking the pipeline.
* The ventilated window is directly connected to the outside world, covered with 0.2µm high efficiency filter membrane, which can be directly washed and autoclavable.
* After the cage box is removed from the cage frame, the air inlet and exhaust valves of the cage box will automatically close immediately.
Model | Cage Number | Cage Frame Size(L*W*H) | Cage Box Size(L*W*H) | Cage Frame & Cage Box Package Size(mm) | Cage Frame & Cage Box Gross Weight |
BK-SL380-60(6*10) | 60 | 1346*500*1990mm | 380*204*162mm | 1446*600*2140mm | 90kg |
BK-SL380-70(7*10) | 70 | 1562*500*1990mm | 380*204*162mm | 1662*600*2140mm | 100kg |
BK-SL380-80(8*10) | 80 | 1778*500*1990mm | 380*204*162mm | 1878*600*2140mm | 106kg |
BK-SL380-90(9*10) | 90 | 1994*500*1990mm | 380*204*162mm | 2094*600*2140mm | 114kg |
BK-SL380-120(6*10)-SM | 120 | 1346*710*1990mm | 380*204*162mm | 1446*810*2140mm | 100kg |
BK-SL380-140(7*10)-SM | 140 | 1562*710*1990mm | 380*204*162mm | 1662*810*2140mm | 120kg |
BK-SL380-160(8*10)-SM | 160 | 1778*710*1990mm | 380*204*162mm | 1878*810*2140mm | 130kg |
BK-SL380-180(9*10)-SM | 180 | 1994*710*1990mm | 380*204*162mm | 2094*810*2140mm | 140 |
Model | Cage Number | Cage Frame Size(L*W*H) | Cage Box Size(L*W*H) | Cage Frame & Cage Box Package Size(mm) | Cage Frame & Cage Box Gross Weight |
BK-SL385-32(4*8) | 32 | 890*500*1960mm | 385*194*172mm | 990*600*2110 | 68kg |
BK-SL385-36(4*9) | 36 | 890*500*2020mm | 385*194*172mm | 990*600*2170 | 73kg |
BK-SL385-40(5*8) | 40 | 1100*500*1960mm | 385*194*172mm | 1200*600*2110 | 77kg |
BK-SL385-45(5*9) | 45 | 1100*500*2020mm | 385*194*172mm | 1200*600*2170 | 82kg |
BK-SL385-48(6*8) | 48 | 1310*500*1960mm | 385*194*172mm | 1410*600*2110 | 85kg |
BK-SL385-54(6*9) | 54 | 1310*500*2020mm | 385*194*172mm | 1410*600*2170 | 90kg |
BK-SL385-56(7*8) | 56 | 1520*500*1960mm | 385*194*172mm | 1620*600*2110 | 90kg |
BK-SL385-63(7*9) | 63 | 1520*500*2020mm | 385*194*172mm | 1620*600*2170 | 95kg |
BK-SL385-64(8*8) | 64 | 1730*500*1960mm | 385*194*172mm | 1830*600*2110 | 100kg |
BK-SL385-72(8*9) | 72 | 1730*500*2020mm | 385*194*172mm | 1830*600*2170 | 105kg |
BK-SL385-72(9*8) | 72 | 1940*500*1960mm | 385*194*172mm | 2040*600*2110 | 105kg |
BK-SL385-81(9*9) | 81 | 1940*500*2020mm | 385*194*172mm | 2040*600*2170 | 110kg |
BK-SL385-96(6*8)-SM | 96 | 1310*710*1960mm | 385*194*172mm | 1410*810*2110 | 105kg |
BK-SL385-108(6*9)-SM | 108 | 1310*710*2020mm | 385*194*172mm | 1410*810*2170 | 115kg |
BK-SL385-112(7*8)-SM | 112 | 1520*710*1960mm | 385*194*172mm | 1620*810*2110 | 115kg |
BK-SL385-126(7*9)-SM | 126 | 1520*710*2020mm | 385*194*172mm | 1620*810*2170 | 125kg |
BK-SL385-128(8*8)-SM | 128 | 1730*710*1960mm | 385*194*172mm | 1830*810*2110 | 126kg |
BK-SL385-144(8*9)-SM | 144 | 1730*710*2020mm | 385*194*172mm | 1830*810*2170 | 136kg |
BK-SL385-144(9*8)-SM | 144 | 1940*710*1960mm | 385*194*172mm | 2040*810*2110mm | 146k |

Introduction:
The animal cage changing station is suitable for the replacement of animal cages in SPF animal rooms, the anatomy of experimental
animals and the separation of tissues, etc. It adopts positive vertical flow, double primary effect and double high efficiency
filtration design, which can prevent animals in the work area from being polluted by outside air. Protect the operator from
allergens and special odors generated during the experiment. In addition, the double-sided open design facilitates simultaneous
operation by multiple person. It is a safety protection device specially designed for animal research laboratories.
The animal cage changing station is suitable for the replacement of animal cages in SPF animal rooms, the anatomy of experimental
animals and the separation of tissues, etc. It adopts positive vertical flow, double primary effect and double high efficiency
filtration design, which can prevent animals in the work area from being polluted by outside air. Protect the operator from
allergens and special odors generated during the experiment. In addition, the double-sided open design facilitates simultaneous
operation by multiple person. It is a safety protection device specially designed for animal research laboratories.
Advantage:
1. Automatic feed water system, labor saving.
2. Special sealing design, ensure good sealing performance.
3. Manipulation of the chicken or equipment can be realized via gloves from both sides.
4. Adopt full 304 stainless steel material, high quality accessories, such as Butyl gloves, HEPA filter etc.
5. Filtration system, can protect animals, environment and operator.
Pre-filter→ main HEPA filter→Filter cotton.
6. Three sterilization ways available.
UV lamp for sterilization.
Reserved hole for hot steam sterilization.
Reserved hole for disinfectant spraying sterilization.
7. Unique defecation system & fecal leakage shelf. Animal wastes drop from shelf to bottom fecal collection film, then pull of collecting film and clean out wastes conveniently and quickly, reduce the cleaning frequency.
1. Automatic feed water system, labor saving.
2. Special sealing design, ensure good sealing performance.
3. Manipulation of the chicken or equipment can be realized via gloves from both sides.
4. Adopt full 304 stainless steel material, high quality accessories, such as Butyl gloves, HEPA filter etc.
5. Filtration system, can protect animals, environment and operator.
Pre-filter→ main HEPA filter→Filter cotton.
6. Three sterilization ways available.
UV lamp for sterilization.
Reserved hole for hot steam sterilization.
Reserved hole for disinfectant spraying sterilization.
7. Unique defecation system & fecal leakage shelf. Animal wastes drop from shelf to bottom fecal collection film, then pull of collecting film and clean out wastes conveniently and quickly, reduce the cleaning frequency.