Biobase 190-900nm Wavelength Atomic Absorption Spectrophotometer Bk-AA320n for Lab

Price $8000.00 Compare
Min Order 1 Piece
Shipping From Shandong, China
Popularity 493 people viewed
Quantity
+-
 

Biobase Biosun Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
BK-AA320N
Online Service
Laboratory Apparatus
1 Year
Spectrophotometer
High Sensitive
Classic Spectrometer
Atomic
/
/
CE
Non-Customized
Bk-AA320n
White
One Year
190~900nm
≤±0.5nm
≤ 0.3nm (Single Direction)
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
1800 Lines/mm
<40%
±0.004ABS/30min
≤ 0.04μg/Ml/1% (Cu)
≤0.008μg/Ml (Cu)
Higher Than 30 Times
220V, 50/60Hz
138kg (Main Instrument) 56kg ( Accessories )
BIOBASE
Carton
138kg
China
Product Description
Product Description

BIOBASE 190-900nm wavelength Atomic Absorption Spectrophotometer BK-AA320N for lab



Features:
1. Build-in computer data processing and LCD display.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
3. Quickly: The cathode lamp does not need to be pre-heated for long time and sample can be analyzed immediately.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
6. High energy optical path.
7. Long-life and anti-corrosive atomization system.
8. Multi-functional analysis mode: ?flame absorption?flame emission? graphite furnace atomic absorption 4 hydride generation.
9. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.

 
Detailed Photos

 

Product Parameters

 

Model

BK-AA320N

Wavelength Range

190~900nm

Wavelength Accuracy

≤±0.5nm

Wavelength Repeatability

≤ 0.3nm (single direction)

Spectral Bandwidth

0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

Grating

1800 lines/mm

Resolution

<40%

Base Line Stability

±0.004Abs/30min

Characteristic Concentration

≤ 0.04μg/ml/1% (Cu)

Detection Limit

≤0.008μg/ml (Cu)

Background Calibration

>30 times

Power Supply

220V, 50/60Hz

Packing Size(mm)

1250*795*765 (Main instrument)

545*445*1385 ( Accessories )

Gross Weight(kg)

138Kg (Main instrument)

56Kg ( Accessories )

Standard Accessories

RS232 serial port

Oil-free air compressor

Glass Atomizer

Cu Hollow cathode lamp

Atomizer unit, Burner unit ,Dust cover

Water-separating gas filter

Titanium burner---10cm

Optional Accessories

Model GA3202 HGA graphite furnace system

Hydride generator

Graphite tubes

Recirculating cooling water system

Hollow cathode lamp(Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K, AU, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)


Company Profile

 