Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory

Price $5930.00 Compare
Min Order 1 Piece
Shipping From Shandong, China
Popularity 259 people viewed
Quantity
+-
 

Biobase Biosun Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
BK-AA320N
Online Technical Support
1 Year
CE
Atomic Absorption Spectrophotometer
Bk-AA320n
190~900nm
Less Than 0.5nm
≤ 0.3nm (Single Direction)
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
1800 Lines/mm
<40%
±0.004ABS/30min
≤ 0.04μg/Ml/1% (Cu)
More Than 30 Times
220V, 50/60Hz
1250*795*765 (Main Instrument) 545*445*1385 ( Acce
138kg (Main Instrument) 56kg ( Accessories )
BIOBASE
Carton Box
1250*795*765mm(
China
Product Description

Product Description

Introduction:


 
 

Features:

1. Build-in computer data processing and LCD display.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
3. Quickly: The cathode lamp does not need to be pre-heated for long time and sample can be analyzed immediately.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
6. High energy optical path.
7. Long-life and anti-corrosive atomization system.
8. Multi-functional analysis mode: a. flame absorption b. flame emission c. graphite furnace atomic absorption d. hydride generation.
9. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.

Product Parameters

Model
BK-AA320N
Wavelength Range
190~900nm
Wavelength Accuracy
≤±0.5nm
Wavelength Repeatability
≤ 0.3nm (single direction)
Spectral Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Grating
1800 lines/mm
Resolution
<40%
Base Line Stability
±0.004Abs/30min
Characteristic Concentration
≤ 0.04μg/ml/1% (Cu)
Detection Limit
≤0.008μg/ml (Cu)
Background Calibration
>30 times
Power Supply
220V, 50/60Hz
Packing Size(mm)
1250*795*765 (Main instrument)
545*445*1385 ( Accessories )
Gross Weight(kg)
138Kg (Main instrument)
56Kg ( Accessories )
Standard Accessories
RS232 serial port
Oil-free air compressor
Glass Atomizer
Cu Hollow cathode lamp
Atomizer unit, Burner unit ,Dust cover
Water-separating gas filter
Titanium burner---10cm
Optional Accessories
Model GA3202 HGA graphite furnace system
Hydride generator
Graphite tubes
Recirculating cooling water system
Hollow cathode lamp(Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K, AU, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)