38kv Pole Mounted Recloser with 6PCS Voltage Sensror with 3 PCS CT in Bushing

Price $5000.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 203 people viewed
Quantity
+-
 

Ningbo Hyuan Power Industry Co., Ltd.

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
CHZ4
High Voltage Circuit Breakers
Electric Type
High-Speed Circuit Breaker
Vacuum
Fixed
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
ISO9001-2000
HEMG
Carton with Wooden
15KV/27KV/38KV, 50HZ/60HZ,
China
Product Description
 
A.- THREE PHASE  RECLOSER  33 KV   
ITEMDESCRIPTIONUNITREQUIREDGUARANTEED
1RECLOSER   
1.01COUNTRY TO INDICATE   CHINA
1.02MANUFACTURER TO INDICATEHEMG
1.03MODEL TO INDICATECHZ4
1.04STANDARD ANSI C-37.60ANSI-37.60
1.05TYPE OUTDOOROUTDOOR
1.06SYSTEM THREE PHASETHREE PHASE
1.07OPERATION TYPE AUTOMATIC AND MANUALAUTOMATIC AND MANUAL
1.08ALTITUDE OF OPERATIONMO.S.L2500 OR MORE2500 OR MORE
 ELECTRIC CHARACTERISTICS   
1.09OPERATION  VOLTAGEKV3333
1.10MAX, VOLTAGE OF THE EQUIPMENTKV3838
1.11NOMINAL  FREQUENCYHZ6060
1.12NOMINAL CURRENTA630630
1.13NOMINAL SYMETRIC INTERRPTION CURRENTKA12.512.5
1.14SPECIFIC  LEAKAGE  DISTANCEmm/KV3131
1.15BILKV170170
1.16DISCHARGE VOLTAGE, DRY, 60 HZ, 1 MINUTEKV7070
1.17DISCHARGE VOLTAGE, WET, 60 HZ, 10 SECONDSKV6060
1.18CYCLE OF WORK ACCORD  ANSI C-37.60 YESYES
1.19INTERRUPTIION WAY VACUUMVACUUM
1.20INSULATION WAY SOLID DIELECTRIC OR GAS SF6SOLID DIELECTRIC
1.21NUMBER OF ELECTRIC OPERATIONS 1000010000
1.22CURRENT MEASURE WITH CURRENT SENSORSWITH CURRENT TRANSFORMER
 INSTALLATION INDOORINDOOR
 SYSTEM SINGLE PHASESINGLE PHASE
1.23RELATION OF TRANSFORMATIONA400/1.RELATION 1.
1.24PRECISION%1%1%
1.25VOLTAGE MEASURE VOLTAGE SENSORS INTERNALVOLTAGE SENSORS INTERNAL
1.26TYPE CAPACITIVECAPACITIVE
1.27INSTALLATION IN BUSHINGIN BUSHING
1.28PRECISION%2.52.5
1.29QUANTITY 66
1.3SENSITIVE GROUND FAULT CURRENT DETECTION. CURENT  TRANSFORMERSENSITIVE CURRENT TRANSFORMER
 INSTALLATION. IN THE TANK (INSIDE THE TANK )IN THE CONTROL BOX
 QUANTITY. 11
 TRANSFORMATION RELATION.Ma200/1.5(200/1.5)
 MECHANIC CHARACTERISTICS   
1.3METALLIC HARDWARE   
 MATERIAL STAINLESSSTAINLESS
 STANDARD OF THE MATERIAL ASTM A575ASTM A575
 STANDARD OF HOT GALVANIZED ASTM A 153ASTM A 153
 THICKNEES OF GALAVANIZATION MINgr/CM2800800
1.31MOUNTING ON CIRCULAR POLEON CIRCULAR POLE
1.32MECHANISM OF OPERATION MAGNETIC ACTUATORMAGNETIC ACTUATOR
1.33POSITION INDICATOR VISIBLE FROM THE SOILVISIBLE FROM THE SOIL
1.34OPERATION BETWEEN POLE WITH  HOOK YESYES
1.35MANUAL LOCKING EMERGENCY (ATTACHED DRAWING) YESYES
1.36TOOL PROVIDED WITH MANUAL CONTROL YESYES
1.37 WITH LIFTING HOOKS YESYES
1.38INDICATES THE LIFE OF CONTACTS YESYES
1.39NUMBER OF MECHANICS OPERATION 10000 OR MORE10000 OR MORE
1.40FULLY  ASSEMBLED YESYES
1.41WEIGHT      
 PRINCIPAL TANKKGTO INDICATE135
 CONTROL BOXKGTO INDICATE35
2TANK   
2.01MATERIAL STAINLESS STEELSTAINLESS STEEL
 CONSTRUCTION REQUIREMENTS INDICATE THE STANDARDINDICATE THE STANDARD
2.02 COATING OF TIN IN TERMINALS AND CONDUCTIVE  PARTS. 8 um8 um
2.03PROTECTION DEGREE Able to withstand pressure fresh water cleaning insulators.Able to withstand pressure fresh water cleaning insulators.
3BUSHINGS   
3.01COUNTRY TO INDICATECHINA
3.02MANUFACTURER TO INDICATEXINXIN
3.03STANDARD ASTM D624, DIN 63504,IEC 60587,ASTM G154, AST G 155.ASTM D624, DIN 63504,IEC 60587,ASTM G154, AST G 155.
3.04CHARACTERISTICS OF MANUFACTURE   
 MATERIAL  OF CORE FIBER GLASS OR RESYNRESYN
 INSULATION MATERIAL OF COVER HOUSING AND SHEDS Cycloaliphatic EPOXY RESINCycloaliphatic EPOXY RESIN
 ELONGATION AT BREAK%450 ( ACCORD STANDARD DIN 53504 )450
3.05TEAR RESISTANCE.N/MMAJOR OF 20 ( Standard ASTM D624)20
3.06TRACKING AND EROSION RESISTANCE. CLASS 2A,4.5 ( IEC 60587 )CLASS 2A,4.5 ( IEC 60587 )
3.07TESTING OF RESISTANCE TO UV RAYS. ACCORDING ASTM G154 AND ASTM G155ACCORDING ASTM G154 AND ASTM G155
3.08RANGE OF SECTION OF DRIVERS. 16  TO 120 MM216  TO 120 MM2
3.09CONDUCTOR MATERIAL OF ELIGIBLE. CU/AL , CU/CU , AL/ALCU
4SYSTEM OF CONTROL AND PROTECTION    
4.01COUNTRY SAME COUNTRY  INDICATE POINT 1.1China
4.02STANDARD OF MANUFACTURE ANSI / IEEE 37.90ANSI / IEEE 37.90
4.03INSTALLATION OUTDOOROUTDOOR
4.04MANUFACTURER SAME MANUFACTURER INDICATE POINT 1.2HEMG
4.05CATALOGUE TO INDICATEEnglish Version
4.06MODEL OF ELECTRONIC SYSTEM TO INDICATECHK4
 CONTROL   BOX   
4.07MATERIAL STAINLESS STEELStainless Steel
4.08THICKNESS 2 MM2mm
4.09SURFACE BRIGHT PASSIVATINGBright Passivating
4.10COLOUR TO INDICATERAL7035
4.11PROTECTION DEGRE OF THE BOX   
 CLOSE OPEN IP65IP65/CLOSE
 INSULATION VOLTAGE TO 1 MINUTE 2 KV2KV
 INSULATION VOLTAGE TO IMPULSE 6 KVp6 KVp
 SUPPORT TO INTERFERENCE TESTING ACCORDING TO STANDARDS: SWC ANSI C37.90.1, IEC 61000-4-4-IEC 61000-4-4
 IMMUNITY TO INTERFERENCE RADIO WAVES. IEC 255-22-3 CLASS, ANSI C37.90.2IEC 255-22-3 CLASS
4.12WITH NAMEPLATE YESYes
 CHARACTERISTICS       
4.13FUNCTION WITH MICROPROCESSORYes
4.14PRINCIPAL PROTECTIONS 50/51,50N/51N,SEF,25,27,59,59N, 6750/51,50N/51N,SEF,25,27,59,67
4.15SECONDARY  PROTECTIONS 46.8146/81
4.16ADJUSTEMENT  GROUPS 2 MIN3 Groups
4.17MIN CURRENT OF SHOOT   
 FAILURE BETWEEN PHASESA20 or minor≤20A
 FAILURE TO GROUNDA10 or minor≤10A
 SENSITIVY  FAILUREA1 or minor≤1A
4.18SETTING ALLOWS PARAMETERS PROTECTION YESYES
 IEC STANDARD CURVES YESIEC and IEEE curves
 CUSTOM CURVES YESIEC and IEEE curves
4.19FAILURE TO GROUND YESYes
4.20MINIMUN VOLTAGES YES27
4.21OVER VOLTAGE YES59
4.22STATUS  INDICATOR OF RECLOSERS   
 PARAMETERS YESYes
 POSITION OF THE EQUIPMENTS YESYes
4.23ALLOWS STORAGE OPERATING EVENTS   
 OPEN OR CLOSE YESYes
 LOSS VOLTAGE YESYes
 OPERATION CURRENT YESYes
4.24REPORT FUNCTIONS  2G TF Card
 EVENT REGISTRATION NUMBER SYSTEM 20482048
 EVENT REGISTRATION NUMBER OF DIAGNOSIS  512512
 EVENT OF PERFIL LOAD REGISTRATION 512512
 REGSITER OF NUMBER OF SHOOTS YESYes
 REGISTER OF COUNTER OF FAILURES YESYes
 NUMER OF REGISTER WAVE FORM 3232
 REGISTRATION  FORM COMTRADE or software applicationComtrade type
     
4.25REPORT FUNCTIONS   
 ERROR IN THE MEASUREMENT  Yes
 BEFORE FAILURE 1% OR MINOR≤1%
 AFTER FAILURE 3% OR MINOR≤1%
 MEASSUREMENTS OF INSTANTANEOUS VALUES V,I,F,P,QV,I,F,PF,P,Q
 ACTIVE AND REACTIVE POWER YESActive and Reactive Counter
4.26 THE CONTROL MUST HAVE TO DISPLAY DATA AND ADJUSTMENT YES4.3 inch Color LCD touch screen
4.27COMMUNICATIONS PROTOCOL (READY FOR INTEGRATION WITH SYSTEMS SCADA) DNP 3.0DNP3.0
4.28COMMUNICATION PORTS   
 ETHERNET YESRJ45
 COMMUNICATION WITH PERSONAL COMPUTER RS232, ETHERNETRJ45,Wi-Fi,Ethernet
 COMMUNICATION  READ DATA RS232, ETHERNET, RS485Ethernet and RS485
4.29OPTION be commanded remotely WITH RADIO MODEM OR GSM MODEM. YESGSM Modem
 EFFORTS TO SAFE OPERATION. YESYes
 INPUT AND OUTPUT NEEDED FOR THIS EFFECT. YESYes
4.3CONFIURATION  SOFTWARE   
 ENVIROMENT WINDOWSWindows
 SECURITY SYSTEM WITH PASSWORDWith Password
 INFORMATION DISCHARGE YESYes
 PROGRAMMING IN REMOTELY YESBy Ethernet
5AUXILIAR ENERGY FEEDER SYSTEM   
 SYSTEM SINGLE PHASESINGLE PAHSE
 INCLUDE AUXILIAR TRANSFORMER FOR CONTROL BOX YESYES
5.01BATTERY   
 COUNTRY TO INDICATEChina
 MANUFACTURER TO INDICATEYUASA
 TYPE TO INDICATENP7-12
 NOMINAL VOLTAGE TO INDICATEDC24V
 NUMBER OF UNIT OPERATING VOLTAGE TO FAILURES. 10 OR MORE12
 MEASURING THE CONDITION OF THE BATTERY. YESYes
 BATTERY LIFE IN FAILURE OF LACK OF VOLTAGE. 48 HOURS48 Hours
 INCLUDED IN THE CABINET OF CONTROL YESYes
5.02SYSTEM OF CHARGE OF THE BATTERIES   
 COUNTRY TO INDICATEChina
 MANUFACTURER TO INDICATEZeroACME
 AUXILIAR VOLTAGE 220 VACAC 220V
 SYSTEM SINGLE PHASESingle Phase
 COMPATIBLE WITH SPECIFIED BATTERIES YESYes
 INCLUDED IN THE CABINET OF CONTROL YESYes
 


 