PW-100T5
Basic Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Ordinary
AC Rotating Exciter
GTL
Standard Export Packaging or as Customer Requireme
3650*1320*2040mm, 2700Kg
Fujian, China
850211
Product Description

Product Description


! Cooling system with large size radiator and expansion tank
! Heavy- duty chassis
! Built-in insulation and anti-vibration block
! Free-maintenance battery
! AC alternator for battery charger
! Battery charger
! Cable and bracket for battery
! Battery isolation switch
! Main circuit breaker
! Automatic start control system
! Fuel_ Water separator
! Fuel level sensor
! Oil sump pump
! Full load test
! Comprehensive security protection
! Emergency stop button
PW-100T5 powered by:1104C-44TAG2
Diesel Genset Features P.F=0.8 3Phase | ||||||||||
Generating Set Performance | 50Hz | |||||||||
Service | P.R.P | Standby | ||||||||
Rated output | kVA | 100,0 | 112,5 | |||||||
Active power output | kW | 80,0 | 90,0 | |||||||
Rated Speed | r.p.m | 1500 | ||||||||
Standard Voltage | V | 400/230 | ||||||||
Voltage available | V | 380/220 - 415/240 | ||||||||
Perforemance data refer to Standard Reference Conditions of ISO 8528:+25ºC,100m ALT,relative humidity 30% | ||||||||||
Power reduction acc.to DIN ISO 3046 Standard values:Above 100m ALT approx.1% per 100m.Above 25ºC(77ºF) approx.4% per 10ºC(50ºF). | ||||||||||
Considering cos phi=0.8 | ||||||||||
Prime Mover Performance 1500 r.p.m | ||||||||||
SERVICE | P.R.P | Standby | ||||||||
Rated output | KW | 93,6 | 103 | |||||||
4 stroke Diesel Engine - Injection type | Direct | |||||||||
Aspiration type | . turbocharged, air-to-air charge cooled | |||||||||
Cylinders,number and arrangement | 4-L | |||||||||
Bore×Stroke | mm | 105X127 | ||||||||
Total Displacement | L | 4,4 | ||||||||
Cooling system | Water | |||||||||
Emission Certification | Stage II | |||||||||
Compression ratio | 18.23:1 | |||||||||
Specific fuel consumption(P.R.P) | L/h | 22,6 | ||||||||
Specific oil consumption(at full load) | % | <0.1 | ||||||||
Total coolant capacity | L | 12,6 | ||||||||
Speed governor | Type | Electric | ||||||||
1.P.R.P. Prime Power - ISO 8528:PRIME POWER is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals.The permissible average power output during a 24 hours period shall not exceed 80% of the prime power.10% overload available for governing purposes only. | ||||||||||
2.Max Standby power -ISO 3046 Fuel Stop power:Power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time: 100% load 25h per year ,90% load 200h per year. No overload available. Applicable in case of failure of the main in areas of reliable electrical network. | ||||||||||
Synchronous Generator GTL | ||||||||||
Model | K80G4 | |||||||||
Poles | num | 4 | ||||||||
Winding Conections (standard) | Star-serie | |||||||||
Insulation | class | H | ||||||||
Enclosure(according to IEC-34-5) | IP23 | |||||||||
Phases | 3+N | |||||||||
Votage Regulaors | A.V.R (SX460) | |||||||||
Steady voltage precision | within±1.5% from no load to full loading with cosΦ=0.8-1.0 | |||||||||
Alternator used by GTL Gensets meet the requirements of following Standard:BS5000,VDE0530,NEMA MG1-32,IEC34,CA C22.2-100,AS1359 | ||||||||||
Generationg Set Installation Data 1500 r.p.m | ||||||||||
EXHAUST SYSTEM | ||||||||||
Exhaust Gas Temperature at full load | ºC | 514 | ||||||||
ºF | 957,2 | |||||||||
Exhaust gas flow | L/s | 253,3 | ||||||||
Maximum allowed back pressure | Kpa | 18 | ||||||||
AIR REQUIREMENT | ||||||||||
Air requirement for combustion at 100% load/rated speed | L/s | 100,2 | ||||||||
ft3/min(CFM) | 212,1 | |||||||||
ELECTRIC STARTING SYSTEM | ||||||||||
Starting motor output | kw | 3 | ||||||||
Minimum Recommended Battery Capacity-Cold Soak @ 0 °F (-20 °C) | CCA | 770 | ||||||||
Standard Battery Charging System | A | 65 | ||||||||
Auxiliary voltage | V | 12 | ||||||||
LUBRICATION SYSTEM | ||||||||||
Lube oil system including sump,filters,etc. | L | 8 |
Selection Guide

Company Information

Xiamen GTL Power System Co., Ltd established in 2009, is a professional power generation solutions and supplier located in Xiamen of China, we engaged in the research, development, production, sales, and service of Industrial diesel generator, Mobile diesel generator, Pump diesel generator, Gas generator, Air Compressor, and Light towers.
The Generators we provide can be both in Open skid, weatherproof and Soundproof, power range from 5 kW to 4000 kW;
The Gas generator can range from 12 kW to 1500 kW;
The Air Compressor range from 55 CFM to 1600 CFM, maximum 34.5 bar;
The Light towers were designed to offer the widest choice, multiple solutions of lamps with metal halide floodlight and LED lamp to satisfy different application, additionally, it is totally customizable.