YJLV22 YJLV32 YJLV42.
Insulated
Stranded
Aluminum
PVC
XLPE
Round Wire
Power Transmission
ISO9001, CE, CCC
Qinfong
Black
Yes
1-5
6/10kv, 8.7/15kv, 19/33kv, 26/35kv
Yes
QINFONG
Drum
China
8544609090
Product Description
Voltage: 6/10KV,8.7/15KV,19/33KV,26/35KV
Model: YJLV22 YJLV32 YJLV42...
Applications:
- Substation
- Administration of Power Supply
- Industrial plant
- Outdoor, underground, underwater
- Indoor and cable conduit
Advantages:
Low price, light weight, antioxidant, etc..
Conductor shielding: Non-metallic semiconductor mixture
Insulation: Crosslinked polyethylene
Insulation shield: Non-metallic semiconductor mixture
Metal shield: Copper tape
Filler: Non-hygroscopic material
Binding: Moisture-proof non-woven fabric
Reinforcement: Steel tape armoring(to be customized)
Outer sheath: PVC/PE/LSZH
Physical property:
Conductor maximum operating temperature: 70ºC (PVC insulation), 90ºC (XLPE insulation)
Minimum operating temperature: -5ºC (PVC or LSZH sheath), -20ºC (PE sheath)
Short-circuit temperature (no more than 5 seconds) : 140ºC-160ºC (PVC insulation), 250ºC (XLPE insulation)
3-Core Aluminum Conductor Cable(6/10KV) | |||||||||
No. of Cores and Nominal Cross Section | Thickness of Insulation | Thickness of PVC Gasket | Thickness of Steel Tape | Thickness of Sheath | Approx. Overall Diameter | Approx. Weight | Max. DC Resistance of Conductor (20ºC) | Current Carrying Capacity(Ω/km) | |
(mm2) | (mm) | (mm) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air (A) | In Ground (A) |
3×70 | 3.4 | 1.8 | 0.5 | 2.6 | 56 | 3700 | 0.443 | 175 | 167 |
3×95 | 3.4 | 2 | 0.5 | 2.7 | 60 | 4300 | 0.32 | 211 | 199 |
3×120 | 3.4 | 2 | 0.5 | 2.8 | 63 | 4800 | 0.253 | 241 | 226 |
3×150 | 3.4 | 2 | 0.5 | 3.0 | 66 | 5300 | 0.206 | 271 | 251 |
3×185 | 3.4 | 2.2 | 0.5 | 3.1 | 70 | 6000 | 0.164 | 310 | 284 |
3×240 | 3.4 | 2.2 | 0.5 | 3.3 | 77 | 7000 | 0.125 | 364 | 329 |
3×300 | 3.4 | 2.2 | 0.8 | 3.5 | 81 | 8000 | 0.100 | 413 | 369 |
3×400 | 3.4 | 2.4 | 0.8 | 3.6 | 84 | 9300 | 0.0778 | 470 | 415 |
3-Core Aluminum Conductor Cable(8.7/15KV) | |||||||||
No. of Cores and Nominal Cross Section | Thickness of Insulation | Thickness of PVC Gasket | Thickness of Steel Tape | Thickness of Sheath | Approx. Overall Diameter | Approx. Weight | Max. DC Resistance of Conductor (20ºC) | Current Carrying Capacity(Ω/km) | |
(mm2) | (mm) | (mm) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air (A) | In Ground (A) |
3×70 | 4.5 | 1.8 | 0.5 | 2.8 | 61 | 4200 | 0.443 | 175 | 167 |
3×95 | 4.5 | 2 | 0.5 | 2.9 | 66 | 4800 | 0.32 | 211 | 199 |
3×120 | 4.5 | 2 | 0.5 | 3 | 69 | 5350 | 0.253 | 241 | 226 |
3×150 | 4.5 | 2 | 0.5 | 3.1 | 73 | 6000 | 0.206 | 271 | 251 |
3×185 | 4.5 | 2.2 | 0.5 | 3.3 | 77 | 6500 | 0.164 | 310 | 284 |
3×240 | 4.5 | 2.2 | 0.5 | 3.4 | 81 | 7650 | 0.125 | 364 | 329 |
3×300 | 4.5 | 2.2 | 0.8 | 3.6 | 88 | 9500 | 0.100 | 413 | 369 |
3×400 | 4.5 | 2.4 | 0.8 | 3.8 | 92 | 10000 | 0.0778 | 470 | 415 |
3-Core Aluminum Conductor Cable(12/20KV) | |||||||||
No. of Cores and Nominal Cross Section | Thickness of Insulation | Thickness of PVC Gasket | Thickness of Steel Tape | Thickness of Sheath | Approx. Overall Diameter | Approx. Weight | Max. DC Resistance of Conductor (20ºC) | Current Carrying Capacity(Ω/km) | |
(mm2) | (mm) | (mm) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air (A) | In Ground (A) |
3×70 | 5.5 | 1.9 | 0.5 | 3 | 67 | 4850 | 0.443 | 175 | 167 |
3×95 | 5.5 | 1.9 | 0.5 | 3.1 | 71 | 5400 | 0.32 | 211 | 199 |
3×120 | 5.5 | 2 | 0.5 | 3.2 | 75 | 6000 | 0.253 | 241 | 226 |
3×150 | 5.5 | 2 | 0.5 | 3.3 | 78 | 6500 | 0.206 | 271 | 251 |
3×185 | 5.5 | 2.1 | 0.5 | 3.4 | 81 | 7200 | 0.164 | 310 | 284 |
3×240 | 5.5 | 2.2 | 0.5 | 3.7 | 89 | 9150 | 0.125 | 364 | 329 |
3×300 | 5.5 | 2.3 | 0.5 | 3.8 | 94 | 10300 | 0.100 | 413 | 369 |
3×400 | 5.5 | 2.4 | 0.8 | 4.0 | 96 | 11800 | 0.0778 | 470 | 415 |
3-Core Aluminum Conductor Cable(18/30KV, 19/33KV,26/35KV) | |||||||||
No. of Cores and Nominal Cross Section | Thickness of Insulation | Thickness of PVC Gasket | Thickness of Steel Tape | Thickness of Sheath | Approx. Overall Diameter | Approx. Weight | Max. DC Resistance of Conductor (20ºC) | Current Carrying Capacity(Ω/km) | |
(mm2) | (mm) | (mm) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air (A) | In Ground (A) |
3×70 | 8.0 | 2.3 | 0.8 | 3.3 | 77 | 6200 | 0.443 | 175 | 167 |
3×95 | 8.0 | 2.4 | 0.8 | 3.5 | 82 | 7000 | 0.32 | 211 | 199 |
3×120 | 8.0 | 2.4 | 0.8 | 3.6 | 86 | 8400 | 0.253 | 241 | 226 |
3×150 | 8.0 | 2.5 | 0.8 | 3.7 | 89 | 9000 | 0.206 | 271 | 251 |
3×185 | 8.0 | 2.5 | 0.8 | 3.9 | 93 | 9850 | 0.164 | 310 | 284 |
3×240 | 8.0 | 2.6 | 0.8 | 4.0 | 100 | 11100 | 0.125 | 364 | 329 |
3×300 | 8.0 | 2.7 | 0.8 | 4.2 | 104 | 12400 | 0.100 | 413 | 369 |







1. Is your company a factory or a trading company?
My company is a factory specializing in the production of cables, and the team members have more than 20 years of experience in the cable industry.2. How does your company conduct quality control?
- We conduct strict control over the use of raw materials
- All details of the production process are closely watched by professional workers
- Quality Control Department monitors the whole process of production
- All products can only be delivered after the pass of the inspection by our own testing equipment
Sample is free and customers only need to pay for its delivery.
4. What is your minimum order quantity?
The minimum order quantity varies by product type, please contact us for confirmation.
5. Can you customize it?
Yes. Please provide the specific requirements.
6. How long is your production cycle?
Usually 7-20 days, depending on order quantity and specifications.