Transformer Loss Tangent Tan Delta Test Set 10kv 12kv Automatic Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester

Price $2800.00 Compare
Min Order 1 Piece
Shipping From Hubei, China
Popularity 392 people viewed
Quantity
+-
 

Wuhan Goldhome Hipot Electrical Co., Ltd.

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
HM5006
Life Time Support
1 Year or Extended
Transformer Tester
LCD
28kg
180V-270VAC, 50Hz/60Hz+-1%
10μa-1A
Maximum 0.001PF, 4 Valid Figures.
200mA
<90%
3PF-1.5μf/10kv 60PF-30μf/0
Unlimited, 0.001% Resolution
CE
Factory Report or The Third Party Report
Internal Hv: 3PF~60000PF/10kv 60PF~1μf/0.5kv
Gst, Ust, CVT Ratio
220V or 120V
50Hz or 60Hz
10kv, 12kv, 15kv or Higher
Can Be Customzied
for Transformer Tan Delat Test and CVT Ratio Test
HMDQ
Wooden Box with Foam Inside
460mm*360mm*350mm.
Hubei, China(Mainland)
9030899090
Product Description
transformer loss tangent tan delta test set 10kv 12kv automatic tan delta and capacitance anti-interference dielectric loss dissipation power factor tester 

I. Summary

Tan Delta Test Set is a basic method in insulation test and effectively detect damp, degradation and partial defect of insulation of electrical equipment. This method is widely used in electric manufacturing, electric equipment installation, connection and preventive test. Measurement on dielectric loss of transformer, mutual inductor, reactor, capacitor, bushing and arrester is the most basic method to test their insulation property.**** fully-automatic anti-interference dielectric loss tester breaks through the traditional bridge testing method and adopts variable frequency power technology, single chip and modernized electrical technology to carry out automatic frequency shift, analog-to-digital conversion and data computing. It features strong anti-interference capacity, high test speed, high precision, automatic digitization and easy operation. It adopts high-power switching power supply, which outputs 45Hz and 55Hz pure sine wave and automatically increase the voltage to a maximum value 10 KV. It can filter 50Hz interference automatically, and Tan Delta Test Set is applicable to the site test of substation and other places with large electromagnetic interference. This methods is extensively applied in dielectric loss measurement of transformer, mutual inductor, reactor, bushing, capacitor, arrester and others equipments in power industry.

II. Technical indicators
Accuracy: Cx: ±(reading×1%+1pF)
tgδ: ±(reading×1%+0.00040)
Anti-interference: Variable frequency anti-interference, the above accuracy can be reached under 200% interference. 
Capacitance range: Internal HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV
 External HV: 3pF~1.5μF/10kV 60pF~30μF/0.5kV
 Resolution: Maximum 0.001pF, 4 valid figures. 
tgδ range:unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles. 
Test current range: 10μA~1A
Internal HV: Set voltage range: 0.5~10kV
Maximum output current: 200mA
 Buck-bust method: continuous stepless regulation
 Test frequency: 45, 50, 55 single frequency 45/55Hz automatic dual variable frequency
Frequency accuracy: ±0.01Hz
External HV: In case of UST, maximum test current is 1A,and power frequency or variable frequency is 40-70Hz
In case of GST, maximum test current is 10kV/1A,
and power frequency or variable frequency is 40-70Hz
CVT self-exciting low voltage output: Output voltage 3~50V,
output current 3~30A


V. Company profile photos