JS-8
Working Earthing, Earthing System, Lightning Protection Earthing, Protection Earthin
High Voltage
High Voltage Transmission Line
Indirect Earthing Method
Galvanized Copper
TT
ISO9001
Small
Maiyu Electric
6~35kv
2.5kv
400
65
Carton
17*14*23
Wenzhou, Zhejiang, China
Product Description
Company Profile
Zhejiang Maiyu Electric Co. , Ltd. is a professional manufacturer, high voltage vacuum circuit breaker series, indoor high voltage vacuum circuit breaker series, load switch series, lightning arrester series, high voltage disconnector series, drop fuse series, grounding switch series, cable box series and other electrical equipment companies, the company is composed of a group of people engaged in electrical industry for many years, with professional technical research and development and product sales team,
perfect production equipment, integrity management, strict quality control.
Product Description
The discharge counter for lightning arrester is a high-voltage electrical appliance used to monitor the discharge action of the arrester, and its structure is composed of nonlinear resistance, electromagnetic counter and some electronic components. Under the normal operating voltage, the leakage current flowing through the counter is very small, the counter is small action, when the arrester passes through the lightning wave, the operation wave and the power frequency overvoltage, the strong working current passes through the nonlinear resistance of the counter, and after DC conversion, the electromagnetic counter coil is discharged and the counter is sucked once, so as to realize the device for measuring the number of arrester actions. In the structure, the resistor sheet is used to take the voltage, the electromagnetic counter displays, the transparent glass cover, the sealing rubber pad, the bottom plate and the flange are clamped and sealed, and the high-voltage outlet end is drawn out from the center of the bottom plate.
Product Parameters
Model | Applicable voltage KV(r.m.s) | 8/20uSNominal discharge current rating KA | Nominal discharge current residual voltage &KV | 2 m s Square wave withstand current &A | 4/10UsImpulse high current< span=""> <> | Maximum length mm | weight kg |
JS-8 | 6-35 | 5 | 2.5 | 400 | 65 | 185 | 2.84 |
JSY- 10/600 | 6-110 | 10 | 2.0 | 600 | 100 | 185 | 2.95 |
JSY- 10/800 | 6-220 | 10 | 1.5 | 800 | 100 | 185 | 3.00 |
JCQ-A, B,C | 6-220 | 10 | 1.5 | 6UU-80U | 100 | 185 | 3.20 |
Installation Instructions
Detailed Photos
Certifications
Packaging & Shipping