PC200
Physiological Functions of Diagnosis and Monitoring Equipment
Patient Monitor
CE, MSDS, ISO13485
All Human and Animal
4 Inch Color TFT
0.05%-20%
Hand Held Patient Monitor
3/5 Leads ECG/Etco2+SpO2+NIBP+Temp
Adult/PED/Neo
Support
100
320*480
Yes
Spot, Monitoring
Historical Data View and Trend Chart Back to See
Lithium Ion Battery
Probe off, Low Power
Union Medical
Carton
China
9018193010
Product Description
(PC200)Medical/Hospital/ICU Handheld Multiple Parameters Vital Signs Monitor
Model:PC200
Parameters:ECG/ETCO2+SPO2+NIBP+TEMP
1. The smart and exquisite handheld patient monitor
2. ECG:3/5 Leads, 3 waves
3. Accurate measurement in low perfusion index
4. Accurate measurement
5. NIBP adopt SAWAA(Self-Adaptive-Waveform-Amplitude-Adjust)algorithm and SAFD(Self-Adaptive-Fast-Deflation)algorithm
6. Easy operation by 4"color TFT screen and Up to 100users ID switch
7. Multiple vital signs measurement parameters for collocation optional
l 3/5 Leads ECG, NIBP, SPO2, TEMP
l NIBP, SPO2, TEMP, CO2
8. Two measurements mode:Spot,Monitoring
9. Data storage capabilities,support for historical data view and trend chart back to see
l In monitoring mode,can continuously record 48 hours of measurement data
l In spot mode,100users ID,each user can store 200sets data
10. Support audio and visual alarm,support to set alarm uper and lower limit values
11. Lithium ion battery power supply



Perfomance Specifications:
Display | 4" color TFT | Resolution | 320*480 |
Indicator | Alarm indicator,Power indicator | Trace | 1 plethysmogram waveform |
Alarm | Probe off,low power | modes | visual and audio |
Application | Neonatal/newborn,pediatric and adult patients |
Parameters Performance:
ECG
Lead | 7 lead(R, L, F, N, C1 or RA, LA, LL, RL, V1) |
Lead mode | I, II, III, aVR, aVL, aVF, V1, CAL |
Wave | 3 waves |
Gain selection | 0.25V/mV, 0.5V/mV, 1V/mV, 2V/mV |
Heart Rate | Adult | PED/NEO |
Range | 15-300 bpm | 15-350 bpm |
Accuracy | +/- 1% or +/- 1bpm Bigger | |
Resolution | 1bpm | |
Sensitivity | >200 uV( peak to peak ) |
Bandwidth | |
Diagnostic | 0.05-100 Hz |
Monitor | 0.5-40 Hz |
Surgery | 1-20 Hz |
Stronger Filter | 5-20 Hz |
NIBP
Adult | PED | NEO | |
SYS | 40~270mmHg | 40~200mmHg | 40~135mmHg |
MEAN | 20~230mmHg | 20~165mmHg | 20~105mmHg |
DIA | 10~210mmHg | 10~150mmHg | 10~95mmHg |
Pulse Rate Range:40~240bpm | |||
NIBP measurement accuracy | ±3mmHg | ||
Pulse rate measurement accuracy | ≤2%(≥100bpm)or 2beats/min(<100BPM) |
Independent software protection pressure | ||
Adult:300mmHg | PED:240mmHg | NEO:150mmHg |
Independent hardware protection pressure | ||
Adult:320-330mmHg | PED:265-275mmHg | NEO:160-165mmHg |
Oxygen Saturation(%SPO2)
Measurement Range | |||
Measure Range | SPO2:0-100% | PR:0-254BPM | Perfusion index:0.05%-20% |
Accuracy Range | SPO2 saturation:70-100% | Pulse Rate:30-254BPM | |
Measurement Accuracy | |||
SPO2 | |||
Adult(including pediatric):±2digit(70-100%) not defined(<70%) | Neonate:±3digits not defined(<70%) | On motion condition :±3digits | |
Pulse Rate | |||
Adult(including pediatric):±3digits | Neonate:±3digits | On motion condition::±3digits | |
Resolution | |||
SPO2 saturation:1% | Pulse Rate:1BPM |
TEMP
Measurement range | 25-45°C |
Resolution | 0.1°C |
Accuracy | 0.1°C |
Power Type: Lithium ion battery
Operation time: 8 hours for normal operation
PC200 for animal/vet



Our wide monitor series:

Warranty:
1 year for main unit, 6 months for accessories.
Other Product Lines:


Warranty:
1 year for main unit, 6 months for accessories.
According Products:
-Pulse oximeter/Vital Sign Monitor(handheld/fingertip)
-Patient Monitor
-ECG machine(Electrocardiograph)
-OEM Patient Monitoring Modules
-Infusion/Syringe Pump
-HFNC Machine and CPAP Machine
-Veterinary products


Payment

Shipping

Contact: Yuki.Cai