Ycqr7 Industrial Soft Starter with RS485 Communication and Programmable Relay

Price $70.98 Compare
Min Order 6 Pieces
Shipping From Zhejiang, China
Popularity 465 people viewed
Quantity
+-
 

Changcheng Electrical Group Zhejiang Technology Co., Ltd.

VIP   Audited Supplier 20 years
Profile Certified by SGS/BV
YCQR7
Following
Closed-Loop
Continuous
Automatic Control, Protection
RoHS, CCC, ISO: 9001, CE
Used
Non-Customized
Aluminum Alloy
3 Phase Rat Cage Asynchronous Motor
5.5-450kw
380V
50/60Hz
3 Road
Over a Long Period of Time
4 Line Cog Screen
Chinese, English
CNC
Standard Packaging
YCQR7
Zhejiang, China
85362000
Product Description


Product Description

General
Read the ZR 900 installation instructions carefully before use. If you do not read the relevant instructions carefully, you will violate the relevant safety regulations, which may affect the normal use of the soft starter. To install the ZR900, please prepare the following tools : small word screwdriver, wire cutter, wrench, etc.

Operating conditions
Incoming line power supply: AC 380V ± 5% 50/60 HZ
Power supply is applicable: mouse cage three-phase asynchronous motor
Cooling mode: forced air cooling
App licable temperature: -10°C ~ ± 40°C ,1°C,2%, + 50°C
App licable humidity: 90% without frost
Place of use: No corrosive gas without conductive dust indoor is well ventilated
Elevation vibration: The altitude is below 3000 meters, and the vibration power device is below 0.5G
Technical data
 

project nameperformance index
scope of application3 phase rat cage asynchronous motor
power bracket5.5-450kW
input voltage380V ± 15%
supply frequency50/60HZ ± 5%
overload capacity400%60sec,120% continuous
Adjustable current multipleFrom 1 to 5 times each time
Soft up time1-90 Seconds
Module working modeover a long period of time
cooling-down methodforced air cooling

Secondary interace terminal
on-off input3 Road
relay output1 (programmable) or 3 (programmable)
4-20MARoute (extension is optional)
RS4851-way (extended as optional)
ProtectShort circuit speed break, overcurrent, overheat protection, reverse time
overload, voltage phase deficiency, imbalance, lnsient stop, undervoltage,
overvoltage, underload, starting failure, phase sequence error.
Host overload protectionOverload and reverse time limit, level 1 -5 is optional
Host current imbalance protectionUnbalanced trip standard: 5- 100% any two-phase unbalanced trip delay: 1-60 seconds can be set
Host short circuit protectionQuick break time . 0.18, can be set
Bus functionInterface : RS485 protocol · ModbusRTU
human-computer interface4 Line COG Screen
LanguageChinese, English

Technical data
 

Order numberNameSet the scopeWindows defaultExplain
Soft-up parameters
A1Start way0~330: aging 1: voltage ramp
2: constant current3:current ramp
A2Starting voltage0~100%45%0,1,2 The starting mode is effective
A3Initial current0~2.5 Times2.0 TimesMethod 3 valid
A4Flow limit multiple1.8~6.0 Times3.5 TimesMethod 1,2,3 valid
A5Sudden jump peak0~10090% 
A6The jump cycle0~2.0S0.4S 
A7Start delay0~240.0S0.0SDelayed start time
A8Soft up time0~90.0S20.0SAll starting modes are valid
A9Soft stop time0~60S0SSet to 0 no soft stop function, non-0 valid
A10Joint control delay0~240.0S0.0SStart the delay relay output, use with programmable relay

A11
mode of operation
0~6

3
0: Full open 1: keyboard 2: external control
3: keyboard + external control 4: Communication 5:Communication
+ keyboard
6:communication + external control
A12Rated current0~Current limit100ASet according to the rated current on the motor nameplate
A13Upper limitcurrent0~200%120%The relay is set to feed effectively
A14Lower limit current0~120%90%The relay is set to feed effectively
A15actuation time0~10.0S1.0SThe relay is set to feed effectively
A16Soft startplus time0~60.0S0"Soft start time" does not complete the start, automatic extra time
A17Soft strength2.0 Times0"Soft start time" does not complete the start, automatic extra time
Protection parameters
A18Short circuit multiple0~12.0 Times5.5 TimesSet greater than (current limit multiple + soft starting force + 0.5), the whole process is effective
A19Speed break time0~2.00S0.20SShort circuit block (break) time
A20Overflow multiple0~8.01.2Bypass effective
A21Overflow time0~60.0S10.0SIf the overflow exceeds this value, block the silicon
A22Overheat time0~60.0S10.0SWhen oyerheating exceeds this value, blocking the SCR,the whole process is effective
A23Overload curve1~61Motor reverse time limit protection, reverse time limit curve
number, the larger the value, the longer the time, bypass (full
pressure) after the effective
A24Lack of phase time0~60.0S10.0SIf the voltage phase deficiency exceeds this value,the SCR is blocked, and the whole process is effective
A25Current imbalance0~100%30%Current imbalance ratio, soft rise, bypass, soft stop effective
A26Imbalance time0~60.0S5.0SIf the accumulated time of imbalance exceeds this value, block the silicon controller
A27Underpress ure lower limit0~100%70%Full effective
A28Overpressure time0~60.0S2.0SIf the accumulated time of underpressure exceeds this value, the thyristor is blocked
A29Overpressure upper limit0~150%120%Full effective
A30Overpressure time0~60.0S2.0SIf the cumulative time of overpressure exceeds this value,the thyristors is blocked
A31Under-load current0~100%50%Lower undercurrent, bypass and full pressure effective
A32Adue time0~30.0s2.0sIf the cumulative time exceeds this value, the thyristor is blocked
Protection switch
A33Short-circuiting switchClose, openOpenOutput short-circuit protection is enabled or prohibited
A34Overflow switchClose, openOpenOvercurrent protection enables or forbids
A35Overheat awitchClose, openOpenOverheat protection enables or prohibited
A36overload cut-outClose, openOpenMotor overload protection is enabled or prohibited
A37Lack of phases witchClose, openOpenInput voltage phase absence protection enabled or prohibition
A38Imbalance switchClose, openOpenCurrent imbalance (output phase deficiency) protection enabled or prohibition
A39Instantaneo us stop switchClose, openOpenExternal instantaneous stop fault protection enabled or prohibited, enabling can be set to self-recovery
A40Undervoltag e switchClose, openOpenInput voltage protection enabled or prohibited
A41Overvoltage switchClose, openOpenInput voltage overvoltage protection enable or prohibited
A42Starting failureClose, openOpenMotor is not enabled or prohibited by full speed protection during
bypass (or full pressure)
A43Underload switchClose, openOpenUnderload protection is enabled or prohibited
A44Phase sequence switchClose, openOpenPhase order error protection enables or prohibition
Communication parameters : not considered when not used
A45principal and subordinate0,1,200:Close 1:Host 2:slave
A46Stop number0~321 
A47Digit capacity0~128Usually set to 8
A48Stop bit0~20Usually set to 1
A49Even-odd check0~21Usually set to 0
A50Baud rate0~968Actual baud rate-baud rate*1200
A51Current range0~600010004 mA corresponds to 0 and 20 macorresponds to range values
Control
A52Customer privilege  Password 10, go to the customer privilege menu
A53Manufacturer setting  Password 111,enter the manufacturer setting menu

Specifications and modelsOverall dimensions(mm)Installation size(mm)
W1H1DW2H2D
18.5kW-37kW10524017085214M6
45kW-75kW150280179117240M6
90kW-115kW200370214168328M6
 