ZKG-3A
Adjust
Combination
Linear
Continuous
Automatic Control, Monitoring, Measurement
ISO: 9001, CE
New
Non-Customized
Industrial Flame Retardant Plastics
48*48*78mm
45*45mm
220VAC +/- 10%
0~220VAC
Aoyi
Carton
ZKG-3A
China
9030390000
Product Description
Model(ZKG Series) | ZKG-2A | ZKG-3A |
Dimension | 48*48*78mm | 48*48*78mm |
Install Hole | 45*45mm | 45*45mm |
Work Voltage | 220vac +/- 10% 50Hz (accept customized spec) , Power Loss <3w | |
Adjust Range | 0~220vac | |
Output Characteristic | stabilized voltage output | |
Install Mode | Panel Type |
- Terminals: L,N are the input terminals of the operating power supply of the machine. L is the phase line(commonly known as live wire).N is the neutral wire (commonly known as the earth wire).G1,K1:the first group of the machine triggers pulse signals.G2,K2:the second group of the machine triggers pulse signals. K2 is also the input signal of load voltage feedback.
- External parts: LOAD-load(heating equipment). FU: fuse. A1,K2,G1: the first unidirectional thyristor electrode, A1 is the anode, K1 is the cathode, G1 is the controllable electrode; A2, K2, G2: the second unidirectional thyristor electrode, A2 is the anode, K2 is the cathode, and G2 is the controllable electrode. L,N-outside power supply incoming line, L is the phase line(commonly known as live wire).N is the neutral wire (commonly known as the earth wire).

Installation Attentions
- Connect the output, feedback, power supply, ground wire and electric furnace connection according to the wiring diagram. The load phase must be the same as the voltage regulator power supply phase (ie, in same phase), otherwise the voltage regulator will be damaged.
- The thyristor ZKG controller withstand voltage must be more than 2.5 times of the supply voltage (eg 220V for use, ZKD withstand voltage must >=AC600V), and its rated current must be more than 1.5 times the actual current used. To ensure thyristor ZKG temperature not exceed 70ºC, thyristor ZKG should be equipped with a large enough heat sink, and in a good ventilation and heat dissipation circumstances.
- The series fuse must be connected to the input terminal of the phase line and must not be connected to other positions.
- Thyristor radiator, it's installation should be fully considered protected to prevent electric shock and short circuit between the ZKG controllers.
- The current meter must be connected in series with the T2 terminal of the ZKG. Do not let the trigger signal flow pass through the ammeter.
- The trigger circuit (G1, K1 and G2,K2) signal lines of the machine connected to the thyristor. G1,K1(or G2,K2) should be twisted pair or double core shielded insulated wire. It should be as short as possible and routed separately from other wires to avoid mutual interference and cause(cause) the thyristor out of control.
- Applicable load: constant resistance heating wire, IR far infrared, UV lamp.
Operation
1. Adjust the add-on key "∧" or the subtraction key "∨" on the panel. "SV" shows the set voltage value, "PV" shows the voltage on the load, and press the "P" key to pause powering on the load.
2. The regulator uses voltage negative feedback. It is forbidden to supply half-wave power to the load, so as to avoid the DC power on the load from burning the feedback transformer inside the instrument. In normal use, it should also prevent the single-sided conduction of the thyristor. It is strictly forbidden to supply half-wave power to the load, so as to prevent the DC power on the load from burning the instrument, and also to prevent the single-sided conduction of the thyristor in normal use
3. Do not drive inductive loads like induction furnaces and step-down transformers to prevent damage to the thyristor.
4. If the thyristor cannot be fully turned on or the output is seriously jittered, the trigger connection is reversed, and the two trigger signal output lines can be reversed.
5. "Safety first" After the machine is powered on, do not touch the exposed metal parts of the unit to avoid personal electric shock. If the unit is not normal, do not open it randomly, and it must be handled by professionals.
Others
The instrument should be stored in a place where is dry, ventilated, non-corrosive gas, and the ambient temperature and relative humidity should meet the technical requirements.
Established in 2007, Shanghai/Huangshan Aoyi Electric Co., Ltd is a manufacturer and trader specialized in the research, production and development of Temperature control electric company. Our products include pointer meters, current and voltage meters, solid state relays, SCR power regulators, voltage regulators and intelligent temperature controller.
We are located in Shanghai, China's trade center, more than 100 outstanding employees. All of our products have obtained CCC, CE and passed ISO9001 international quality standards test. As a result of our excellent products and outstanding customer service, we have established a global sales network reaching China, Southeast Asia, Europe, America and other countries. With the strong support of business cooperation friends around the world like you, Our sales are growing every year, we have achieved sales of tens of millions in 2019, and we will keep it up in the future.
If you are interested in any of our products or would like to place an order, please get free to contact us. We are ready and looking forward to forming successful business relationships with new clients around the world in the near future. Let's achieve success together and take our business one step further
Zhang Qifa, the founder of Shanghai Aoyi Electric Co., Ltd, has been engaged in the temperature control electronics industry for more than 30 years. His business philosophy is quality first, integrity management, scientific and technological innovation, and welcomes friends from outside with excellent products and services.