HWF160-10NH
ISO
Vertical
Industrial
Electric Holding Furnace
Ceramic Sintering
Electric
Vacuum/Nitrogen/Hydrogen
500*500*650mm(W*H*D)
Chitherm
Wooden Packaging
1650*1950*2000mm(W*H*D)
China
8514101000
Product Description
1. Application:
2. Technical Specification:
- Rated Temp: 900ºC
- Max Temp: 1100ºC
- Atmosphere: N2, H2, with humidification
- Oxygen Content: Measured by O2 content analyzer
- Muffle Material: SUS 310S
- Muffle Dimensions: φ750mm×900mm(d×D)
- Effective Chamber Dimensions: 500×500×650mm(W×H×D)
- Loading Method: Manual, through horizontal guideway shelves
- Heating Method: Resistance wire pre-built heating plate
- Cooling Method: Air cooling with blower
- Temp. Control Stability: ± 1ºC(controller with P.I.D function)
- Profile Steps: Default 20 steps
- Temp. Uniformity: ± 5ºC
- Thermcouple: Type K
- Temp Control: 3 Points
- Temp. Measurement: 1 Point
- Max. Heating Power: 40kW
- Typical Insulation Power: ≤ 25kW
- Heating Speed: ≤ 5ºC/min
- Furnace Surface Temperature: ≤ 40ºC
- Max Vacuum Value: ≤ 10Pa
- Exhaust System: 1 exhaust port on the top with H2 igniter
- Alarm System: audible and visual alarm in case of over temp, thermcouple broken, low air pressure, low water pressure, substandard vacuum level, etc
- Weight: 1500kg
- Appearance Colour: Light Grey
- External Dimensions: 1650mm×1950mm×2000mm (W×H×D)

3. Delivery List
Table 1 Delivery list | |||
Item | Note | Qty. | |
Basic Components | Furnace | 1 SET | |
inspection certificate | Certificate of major outsourced components | 1 SET | |
Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1 SET | |
Key Components | Heating Element | Resistance wire pre-built heating plate | 1 SET |
Vacuum System | 1 SET | ||
Touch Screen | 1 SET | ||
Temperature Controller | Azbil, CHINO or equivalent brand | 1 SET | |
Thermocouple | Type N | 3 PCs | |
PLC | SIEMENS or equivalent brand | 1 SET | |
Spare Parts | SSR | 1 PC | |
Sealing ring | 1 PC |
4. Facility Requirements
- Environmental Conditions: temp.: 0~40ºC, humidity ≤ 80%RH, no corrosive gas, no strong airflow disturbance
- N2 Conditions: 99.999% purity, working pressure: 0.2-0.4MPa, Max gas consumption 2-6 m3/h
- H2 Conditions: working pressure: 0.2-0.4MPa, Max gas consumption 1-3m3/h
- Compressed Air Condition: dry, clean, oil-free, working pressure: 0.4-0.8MPa
- Water Conditions: clean, no corrosive water, working pressure 0.1-0.3MPa, 3-9L/min
- Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 15m3/h
- Ground Requirements: horizontal, no obvious vibration, load-bearing> 500 kg/m2;
- Power Condition(TBD): capacity > 55kVA, 3-phases 5-lines, voltage 220/380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- Installation Site: 3000mm×2500mm×3000mm(D×W×H), with an installation area greater than 7.5m2.