HRF535-02
ISO
Vertical
Industrial
Electric Holding Furnace
Ceramic Drying
Electric
Nitrogen
850*700*900mm(W*H*D)
Chitherm
Wooden Packaging
1440*1930*1080mm(W*H*D)
China
8514101000
Product Description
1. Applications:
Widely used in processes such as constant temperature drying, curing, and glue dispensing for electronic ceramics and other products.2. Mainly Specifics:
- Rated Temp.: RT+10 ~200ºC
- Max Temp.: 300ºC
- Effective Dimensions: 850×700×900mm(W×D×H)
- Heating Method: Customized Heater
- Process Atmosphere: Nitrogen
- Temperature Control Stability: ±1ºC, with PID parameter self-tuning function
- Temperature Uniformity: better than ±3ºC (insulation 1 hour at 200ºC test)
- Thermocouple: Type K
- Temperature control points: 1
- Temperature monitoring points: 1 point
- Process Steps: 20 steps
- Exhaust: One exhaust port on top
- Alarm System: over temperature, thermocouple failure and other abnormal conditions will activate sound and light alarm protection
- Max Heating Power: 10kW
- Insulation Power: ≤ 5kW
- Surface Temperature Rise: ≤ 35ºC
- Weight: about 700kg
- Furnace Dimensions: about 1400mm×1930mm×1080mm(W×H×D);
- Appearance Color: light gray
3. Delivery List | |||
Item | Note | QTY | |
Basic Compositions | Dryer | 1 PC | |
Certificates of Inspection | Dryer and major purchased components | 1 Set | |
Technical Documents | Manual instructions, technical documents of major purchased components, etc | 1 Set | |
Key Parts | Heating Elements | Customized Heater | 1 Set |
Thermocouple | WATLOW/THERMOWAY, Type K | 1 PC | |
Temperature Controller | 1 Set | ||
Monitor | Touch screen | 1 Set | |
Spares | SSR | 1 PC |
4. Facility Requirements
4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
4.2 Process air conditions: 99.999% purity nitrogen, pressure 0.2 - 0.4Mpa, gas consumption 5-15m3 /h.
4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 15m3 /h;
4.4 Ground requirements: level, no obvious vibration, bearing capacity >300Kg/m2 .
4.5 Power conditions: capacity greater than14kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;
4.6 Installation site: 2500mm×2100mm×3000mm (W×H×D), installation area greater than 5m2.