BF220-17NH
ISO
Vertical
Industrial
Electric Holding Furnace
Drying
Electric
H2/N2
Φ750*500
1 Year
Chitherm
Wooden Packaging
2240*2900*3000mm(W*H*D)
China
8514101000
Product Description
1. Application:
It is mainly used in the high-temperature co-sintering process of alumina substrate and metal slurry (HTCC) in nitrogen-hydrogen atmosphere.
2. Technical Specification:
- Rated Temp.:1600ºC
- Max Temp.:1650ºC
- Effective Dimensions:Φ750×50
- Heating Method: Molybdenum-made heater
- Thermcouple: Type B
- Temperature Control: There are a total of 3 heating groups from top to bottom, with 3 independent temperature control points.
- Temp. Set Accuracy: ±1ºC(flat temp. insulation)
- Temp. Control Mode:control module imported from Japan with PID
- Heat-up Rate : RT~1200ºC≤5ºC/min,1200~1600ºC≤3ºC/mi
- Temp. Uniformity: ± 5ºC (empty furnace insulation test 2hours under 1600ºC)
- Dew point range: -20~60ºC
- Furnace Surface Temperature <35ºC
- Pressure range:5000~15000Pa
- Vacuum detection: vacuum gauge tube detects the vacuum value of the furnace, and the digital vacuum gauge displays the vacuum value.
- Loading Weight ≤ 3500kg (with firing furniture and products)
- Explosion protection: when the furnace pressure is higher than the set value, the exhaust valve will automatically open.
- Exhaust chimney: an exhaust outlet with a ignition device
- Alarm System : Over temperature, broken couple, electric leakage, broken wire, motor overload, humidifier low water level, low pressure, cooling water low water pressure, UPS start alarm and has over temperature alarm power protection function.
- Maximum Heating Power:120kW
- Insulation Power:≤ 60kW
- External Dimensions: 2240×2900×3000mm(W×H×D) (without control cabinet)
- Appearance Color: Light gray

Table 1 Delivery list | |||
Item | Note | Qty. | |
Basic Components | Furnace | 1 SET | |
Inspection Certificates | Certificates of major outsourced components | 1 SET | |
Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1 SET | |
Key Components | Molybdenum wire | Custom-made | 1 SET |
Flow Meter | Azbil or HORIBA | 1 SET | |
Thermocouple | Song Qi | 1 SET | |
Lifting System | 1 SET | ||
Temperature Control Module | Azbil | 3 SET | |
PLC | SIEMENS | 1 SET | |
Touch Screen | MCGS | 1 SET | |
Spare Parts | Heater | 1 PC |
4. Equipment Normal Operating Conditions
- Environmental Conditions: temperature: 0~40ºC, humidity≤ 80%RH, no corrosive gas, no strong airflow disturbance;
- Atmosphere Conditions: dry, clean, oil-free compressed air, working pressure of 0.4- 0.8MPa, gas consumption of 30 - 90 m3/h;
- Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 100 m3/h
- Ground Requirements: horizontal, no obvious vibration, load-bearing> 600 Kg/m2;
- Power Condition(TBD): capacity > 240kVA, 3-phases 5-lines, voltage 220 / 380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- Installation Site: 4000mm×4000mm×5000mm(D×W×H), with an installation area greater than 20m2.