60V60A Energy-Regeneration EV/Phev/Storage Module Battery Charge/Discharge Test System Rechargeable Battery

Price $13778.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 408 people viewed
Quantity
+-
 

Shenzhen Hongda New Energy Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
HD-60V60A8-24CH
Life-Time Sale Service
1 Year
Lithium Battery Pack,Lead-Acid Battery Pack,Nickel
All
Lithium-ion Battery
Customized
AC380V
0V~60V
6V~60V
±0.05%Fs
±0.05%Fs
HONGDIAN
Wooden Case
686mm X 730mm X 1960mm
Dongguan
9030899090
Product Description
 
Product Description

 

Introducing our state-of-the-art 60V60A24CH Energy-Regeneration EV/PHEV/Storage Module Battery Charge/Discharge Test System for Rechargeable Batteries. This cutting-edge system represents the pinnacle of battery testing technology, specifically designed to meet the complex requirements of energy regeneration modules used in Electric Vehicles (EVs), Plug-in Hybrid Electric Vehicles (PHEVs), and energy storage applications.


Designed specifically for testing and analyzing energy-regeneration modules in EVs, PHEVs, and energy storage systems, this system finds applications in industries involved in the development, manufacturing, and quality control of advanced rechargeable batteries.

 
Product Features

 


Multifunctionality: This test system excels in its versatility, offering various testing modes such as constant current charge/discharge, constant voltage charge/discharge, and stepped charge/discharge. This multifunctionality ensures the adaptability required for diverse testing needs across different energy-regeneration applications.

High Precision: With a strong emphasis on precision, the system delivers high-accuracy measurements. This level of precision is crucial for the detailed analysis and evaluation of energy-regeneration modules, ensuring reliable and consistent performance.

Smart Technology: Intelligent features are integrated into the system, allowing for automatic adjustments of testing parameters based on real-time feedback. This smart functionality enhances efficiency, adapting seamlessly to the dynamic characteristics of energy-regeneration modules.

Safety and Reliability: The system prioritizes safety with a comprehensive set of protection features, including safeguards against overcharge, over-discharge, and over-current. These multiple layers of protection ensure a secure and reliable testing process, safeguarding both the equipment and the batteries under examination.

User-Friendly Interface: A user-centric design is adopted, featuring a friendly human-machine interface. This ensures ease of operation, and the intuitive interface simplifies the testing process, making it accessible to users with varying levels of expertise.

 
Product Parameters

 


AC Input Parameters
ItemTechnical Parameters
Wiring MethodAC380V Three-Phase Five-Wire System
Input Power SupplyAC380V
Power Factor≥99%(full load)
THDi≤5%(full load)
Maximum feedback efficiency≥92%(full load)

DC output parameters
ItemTechnical Parameters
Voltage rangeCharging Voltage: 0V ~ 60V Discharging Voltage: 6V ~ 60V
Voltage Accuracy±0.05%FS
Voltage Resolution1mV
Current Range-60A ~ 60A
Current Accuracy±0.05%FS
Current Resolution1mA
Current Response Time10ms(10%FS ~ 90%FS)
Charge/Discharge Conversion Time20ms(-90%FS ~ 90%FS)
Channel Control ModeAll channels can be independently controlled.
Auxiliary channelsEach channel is equipped with an auxiliary temperature channel.


Step Function Features / Function Features of Operation Steps
ItemTechnical Parameters
Minimum Data Logging Time10ms
Editable Number of Steps2000
Number of Step Cycles65535
Step Cycle Nesting5
Charge and Discharge ModesIdle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR)
Termination CriteriaVoltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations)
Execution Action TypesJump, Pause, Protect, Next Step
Importing DBC FilesSupports File Editing, Saving, and Importing
Direct Current Internal Resistance Testing (DCIR)Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I.
Data Export MethodsExport data in Excel and CSV formats.


Protection Functions
ItemTechnical Parameters
AC-Side ProtectionAC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc.
DC-Side ProtectionBus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc.
Battery-Side Comprehensive ProtectionBattery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc.
Ingress Protection (IP) RatingIP22
Operating Temperature Range0ºC~ 45ºC
Cooling MethodForced Air Cooling
Sound Level≤75dB
 
Usage Guidelines

 

Mode Selection: Choose the appropriate testing mode based on specific energy-regeneration module requirements, selecting from constant current, constant voltage, or stepped charge/discharge modes.

Parameter Configuration: Adjust testing parameters such as voltage, current, and duration to align with the specifications of the energy-regeneration module under examination.

Safety Precautions: Prioritize safety by ensuring that protective features, including overcharge, over-discharge, and over-current protection, are enabled before initiating testing.

Data Analysis: Utilize the system's high-precision measurements for in-depth data analysis, drawing insights into the performance and efficiency of energy-regeneration modules.

Routine Maintenance: Perform regular checks and maintenance to ensure the continued accuracy and reliability of the testing system, particularly when dealing with advanced energy-regeneration technologies.

Our 60V60A24CH Energy-Regeneration EV/PHEV/Storage Module Battery Charge/Discharge Test System for Rechargeable Batteries stands as an advanced and user-friendly solution, catering to the intricate testing needs of energy-regeneration modules across various cutting-edge applications.
 
Our Team

 

 
Certifications


 
Message Type
* Message Content
* Name  
* Phone
* Email