37kw Three Phase 200V/400V Frequency Converter/Frequency Inverter/VFD/VSD

Price $9999.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 227 people viewed
Quantity
+-
 

Shenzhen V&T Technologies Co., Ltd.

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
V6-H-4T37G/45L
High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Triple
Vector Control Transducer
PWM Control
Voltage
Low Voltage Variable-Frequency Drive
AC-DC-AC Variable-Frequency Drive
Voltage Variable-Frequency Drive
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
V&T
25
315*575*227(W*H*D)
Built in as Standard
Force Air Cooling
IP20
V&T
Wood
Unit
China
8504409999
Product Description
Product Description

V6-H Series high performance torque control inverter

For over two decades, various industry sectors have been reaping the benefits of V&T's cost-effective, performance-oriented AC Drive solutions. V&T's grasp of specific needs of each industry enables it to offer application-specific solutions for various industries-such as processing ,textile, plastic, ceramic ,pharmaceutical, elevator, oil& gas, power, cement and material-handling.

Main Features

1.Range: 0.4kW to 450kW
2.V/F Control, V/F with PG, Slip Compensation, Sensorless Vector Control, Close Loop Vector Control;
3.Built-in Macro for Crane & Wobbulation;
4.Winder Application;
5.Staring Torque at 180% at 0Hz for Close loop;
6.Optional Smart PLC;
7.Auto Sequence;
8.Droop Control;
9.Built-in RS485 Modbus RTU Communication.
 
 
About the Product

V6-H series torque control inverter generates powerful performance and meets your precise needs through several features: superior V/F control, V/F PG, slip compensation and sensorless vector control as well as closed-loop vector control.
V6-H is perfectly suited for the toughest, most complex application -cranes, plastic winders, high-speed elevators, cement kilns, crushers…and more. It handles loads up to 450kW-HD/600kW -ND, and is engineered to your machine operating at optimum efficiency, even in the hot, humid and dusty conditions that characterize India's industrial environment.

Applications

1. Crane Hoist;
2. Plastic &Textile Machines;
3. Energy-saving air compressor;        
4. Printing;
5. Fan & Pump / HVAC/AHU/Blowers machine /ID/FD Fan

6. Crane Control;          
7. Food & Packaging Industry;        
8. AHU Control.



 
Product Parameters

V6-H-4T XXX GX         Three-phase 400V Constant torque/heavy-duty application
Power (kW)0.751.52.23.75.57.5111518.5223037455575
Motor power (kW)0.751.52.23.75.57.5111518.5223037455575

Output
Voltage (V)                                                              Three−phase 0 to rated input voltage
Rated current (A)2.53.85.59131724303945607591112150
Overload capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)


Input
Rated
voltage/frequency
Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage
range
323V ~ 528V; voltage imbalance 3%; allowable frequency fluctuation: ±5%
Rated current (A)2.84.26.1101519263343506683100123165
Braking unitBuilt−in as standardBuilt−in as option
Protection classIP20
Cooling modeNatural air
cooling
Force air cooling
Power (kW)90110132160185200220250280315355400450500 
Motor power (kW)90110132160185200220250280315355400450500 


Output
Voltage (V)Three−phase 0 to rated input voltage
Rated current (A)176210253304350380426470520600650690775860 
Overload capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)


Input
Rated
voltage/frequency
Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage
range
323V ~ 528V; voltage imbalance 3%; allowable frequency fluctuation: ±5%
Rated current (A)160*196*232*282*326*352*385*437*491*580*624*670*755*840* 
Braking unitExternal braking unit
Protection classIP20
Cooling modeForce air cooling

V6−H−4TXXXL       Three−phase 400V  variable torque/light−load application
Power (kW)1.52.23.75.57.5111518.522303745557590
Motor
power (kW)
1.52.23.75.57.5111518.522303745557590

Output
Voltage (V)Three−phase 0 to rated input voltage
Rated current (A)3.35.07.5111722303744567291110142176
Overload capacity115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)


Input
Rated
voltage/frequency
Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage
fluctuation range
323V ~ 528V; voltage imbalance: 3%; allowable frequency fluctuation: ±5%
Rated current (A)3.65.58.31219253340506280100121156194
Braking unitBuilt−in as standardOptional built−in braking unit
Protection classIP20
Cooling modeNatural air
cooling
Forced air cooling
Power (kW)110132160185200220250280315355400450500560 
Motor
power (kW)
110132160185200220250280315355400450500560 

Output
Voltage (V)Three−phase 0 to rated input voltage
Rated current (A)210253304350380426470520600650690775860950 
Overload capacity115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)

Input
Rated
voltage/frequency
Three−phase 380V/480V; 50Hz/60Hz
Allowable voltage
range
323V ~ 528V; voltage imbalance 3%; allowable frequency fluctuation: ±5%
Rated current (A)196*232*282*326*352*385*437*491*580*624*670*755*840*920* 
Braking unitExternal braking unit
Protection classIP20
Cooling modeForced air cooling

V6−H−2TxxxG  Three−phase 200V  Constant torque/heavy−load application
Power (kW)0.40.751.52.2
Motor
power (kW)
0.40.751.52.2

Output
Voltage (V)Three−phase 0 to rated input voltage
Rated current (A)357.510
Overload capacity150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse
time lag feature)

Input
Rated
voltage/frequency
Three−phase or single−phase 200V ~ 240V; 50Hz/60Hz
Allowable voltage
range
180V ~ 260V; voltage imbalance 3%; allowable frequency fluctuation: ±5%
Rated current (A)3.85.58.312
Braking unitBuilt−in as standard
Protection classIP20
Cooling modeNatural air coolingForced air cooling

Technical Specifications of Product






Control characteristics

Control mode

Vector control 1
Vector control 2 (Without encoder)Vector control 2 (With encoder )
Starting torque0.50Hz 180%0.25Hz 180%0.00Hz 180%
Range of speed regulation
1:100

1:200

1:1000
Precision of steady speed
± 0.5%

± 0.2%

± 0.02%
Torque controlNYY
Precision of torque control

±5%

±5%
Torque response time<20ms<10ms













Product functions



Key functions
Under-voltage regulation, switchover of run command source(operation panel, terminal and communication), speed tracing function, torque limit, multi− step frequency reference(up to 23 step frequency), motor data identification, S curve acceleration and deceleration, slip compensation, PID regulation, droop control, current limit, switch-over between torque control and speed control, manual torque boost and auto torque boost, programmable digital inputs and programmable digital outputs
Frequency reference modeParameter setting, operation panel UP/DN, terminal, terminal UP/DN, communication, analog
( AI1/AI2/AI3), pulse DI , etc.

Frequency range
0.00 ~ 300.00Hz
Note:
In the control mode of vector control 1, frequency range from 0.0Hz to 3000.0Hz can be customized according to the customer demand
Start frequency0.00 ~ 60.00Hz
Acceleration time and deceleration time0.1 ~ 36000s

Dynamic braking
Braking unit action voltage: 650 ~ 750V; operating time: 100.0s
The braking unit can be built-in for V6−H−4T75G and below equipment


DC braking
DC braking start frequency: 0.00 ~ 300.00Hz
DC braking current: constant torque: 0.0 ~ 120.0%, variable torque: 0.0 ~ 90.0% DC braking time: 0.0 ~ 30.0s; DC braking function does not required waiting time to start to realize quick braking
Magnetic flux brakingEnabled or disabled during deceleration are optional, the default setting is enabled






Unique functions

Multi-function M key
The unique multi-function key can be set to frequently used operations: such as JOG, emergency stop, switchover of run command source, switchover of parameters display mode, etc.
Multiple parameters display modesBasic parameters display mode, fast parameters display mode, non−factory setting parameters display mode, last changed 10 parameters display mode

Parameters copy
The standard operation panel can realize the parameters upload, download and display the copy progress. Users can set to forbid overwriting the
uploaded parameters
Displayed and hidden parameters groupThe customer can select to display or hide the parameters group by themselves
Dual 485 communication portsDual 485 communication ports support Modbus protocol (RTU). The maximum distance is 500 meters
 Operation panelKey type or shuttle type operation panel are optional
Protection level: IP20 as standard, IP54 as option
Common DC busAll series product support common DC bus
Independent ductAll series product adopts independentductdesign andsupportsthe
installation of heat-sink outside the cabinet
Universal expansion interfaceUniversal expansion board equipped with CPU for supporting customers secondary development:
physical interface SPI bus, software protocol
 Modbus
 Injection molding machine interface card, PG feedback card, air compressor
Expansion cardcontrol card, communication adapter card, three phase power supply
monitoring card, three phase-sequence detection card, external power
 rectifying card
Power-On-Self-Test (POST)Realizing the POST of internal and peripheral circuits, including motor grounded, abnormal +10V
power supply output, analog input and
 disconnection, etc.




Protection function
Power supply under-voltage, over-current protection, over-voltage protection, interference protection, abnormal comparison level,
motor data identification failure,module(IPM) protection, heat-sink over
 temperature protection, inverter overload protection, motor overload protection,peripheral protection, abnormal current detection, output short circuit to ground , interruption of power supply when in running status, abnormal 
input power, output phase loss, abnormal EEPROM protection, abnormal 
pre-charging contactor detection, temperature sampling disconnection, encoder disconnection, abnormal +10V power supply, abnormal analog input, motor over temperature protection(PTC), abnormal communication, abnormal software version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection, hardware overload protection

Efficiency
At rated power: 7.5kW and below power class ≥93%
45kW and below power class ≥95% 55kW and above power class ≥98%








Environment


Operating site
The product should be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The product should be installed in the environment without dust, corrosive gas, combustible gas, oil mist, steam, drip and free from direct sunlight.

Ambient temperature
−10 to +40ºC, the product must be de-rated rated output current for the ambient temperature between 40ºC to 50ºC, the rated output current must be de-rated for 1% per 1ºC temperature rise
Humidity5 to 95%, no condensing

Altitude
0 to 2000m, the product must be de-rated rated output current for the altitude above 1000 meters, the rated output current must be de-rated for 1% per 100 meters rise
Vibration3.5m/s2,2 to 9Hz; 10 m/s2,9 to 200Hz; 15 m/s2,200 to 500Hz
Storage temperature−40 to +70ºC

Terminal Wiring

Product Component Name


Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA