Specification

Linear: NSL
Wing curved: NA/NP
·Size:
Thickness: 100mm, 150mm, 200mm, 300mm(See left image), 600mm
Size can be customized
·Material:
Galvanized sheet, aluminum sheet, stainless steel sheet, glass fiber wool, etc.
Materials can be customized
·Finish Treatment:
Polyester Powder Coating (PPC)
Any color from the RAL color chart can be chosen
·Other:
Provide stainless steel insect screen




Double-door Single-door
Application
Air inlet of outdoor units such as cooling towers Machine room air inlet
HVAC noise reduction
Data center vents Water pump room air inlet
Transformer/substation sound insulation room heat sink boiler room
Ventilation louvers for construction machinery radiators
Ventilation openings on soundproof enclosures
Wind turbine vent
Acoustic louver door for industrial noise reduction, equipment noise reduction, cooling tower noise reduction, etc.


·Noise reduction effect, quality commitment, empirical test.
·Fire Certified performance data per ASTM-E84.
·Certified performance data per ASTM E90-09.
·Energy-efficient aerodynamic design and a very low pressure drop characteristic.
·Strong weather resistance, easy to clean and convenient for installation and maintenance.
·Select durable metal types combined with our special surface treatment process can guarantee maximum 20 years service life.
·Model, size, material, ventilation rate, noise reduction decibels, color, etc. can be customized. Our professional design team can provide you with satisfactory solutions.
Linear Louver - Sound Transmission Loss (dB)
Octave Band Centre Frequency,Hz | Louvre Depth (mm) | Free area ratio(%) | 63 | 125 | 250 | 500 | 1k | 2k | 4k | 8k | STC CLASS |
NSL-100 | 100 | 40-45% | 4 | 5 | 5 | 6 | 10 | 13 | 14 | 14 | STC10 |
NSL-150 | 150 | 30-35% | 5 | 6 | 8 | 10 | 14 | 18 | 15 | 14 | STC14 |
NSL-150L | 150 | 50% | / | 5 | 6 | 9 | 10 | 12 | 13 | 13 | STC10 |
NSL-200 | 200 | 28-30% | 5 | 6 | 8 | 12 | 20 | 16 | 15 | 15 | STC17 |
NSL-300L | 300 | 50% | / | 6 | 9 | 11 | 18 | 22 | 21 | 20 | STC14 |
NSL-300 | 300 | 45% | 6 | 7 | 10 | 11 | 17 | 17 | 14 | 13 | STC18 |
NSL-600 | 600 | 45% | 6 | 8 | 11 | 24 | 30 | 33 | 29 | 29 | STC26 |
Wing curved louver - Sound Transmission Loss (dB)
Octave Band Centre Frequency,Hz | Louvre Depth (mm) | Free area ratio(%) | 63 | 125 | 250 | 500 | 1k | 2k | 4k | 8k | STC CLASS |
Model NA300 | 300 | 42% | 5 | 6 | 11 | 12 | 12 | 14 | 12 | 10 | STC14 |
Model NA600 | 600 | 42% | 6 | 11 | 15 | 20 | 24 | 27 | 26 | 20 | STC24 |
Model NP300 | 300 | 50% | 4 | 6 | 8 | 10 | 13 | 9 | 7 | 6 | STC11 |
Model NP600 | 600 | 50% | 5 | 10 | 13 | 15 | 22 | 18 | 15 | 13 | STC19 |
NCC Acoustic Laboratory - A Laboratory Professionaly Committed to Serving Customers
We exert every ounce of our strength to construct a high-end, avant-garde laboratory endowed with autonomous control capabilities. For all bespoke products, be it in terms of specifications, dimensions, or acoustic requisites, prior to entering the mass production phase, we shall enforce rigorous and meticulous pre-production sample testing procedures. Only upon thorough confirmation that all indicators are up to par will we invest a considerable amount of human and material resources to embark on mass production endeavors, thereby effectively guaranteeing that each and every batch of large-scale goods delivered to clients possesses outstanding quality.
As depicted in the illustration, the external noise of the laboratory attains 80.1 dB, while through random measurement, the internal acoustic laboratory drops to 36.4 dB or even lower. The elevated standard of sound insulation not only ensures the accuracy of the experimentation but also furnishes a robust guarantee for the test outcomes.



· NCC is the first and currently the only manufacturer in China whose louver series products have passed AMCA certification.
· All Reports can meet the American Standars, the sound testing we did with Intertek







Over the years, NCC has developed into a turnkey supplier of noise control, providing customers with one-stop solutions from concept to completion, including solution consulting, synchronous research and development, construction drawing design, structural design, fluid calculation, air conditioning and electrical system engineering, product manufacturing, installation and commissioning, and testing and acceptance services. With over 70 years of experience in noise control and acoustic engineering, we will provide you with solutions that meet your needs and budget. We look forward to working with you.