Universal Thermocouple Signal Isolator for Optimal System Performance

Price Negotiable Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 316 people viewed
Quantity
+-
 

Nanjing Paragon Technology Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
PZ-15
Adjust
Combination
RoHS, CCC, ISO: 9001, CE
New
Non-Customized
0~400ºC;0~1000ºC;0~1600ºC
1input/1output
0/1~5V;0/4~20mA
0.2%F.S.
35mm DIN Rail
24VDC±10%
PARAGON
Box
ABSflame retardant
China
Product Description
Product Description
Detailed Photos
 
Product Parameters
General
Number of channels1input/1output
Output accuracy (20 ° C)0.2% F.S.
Temperature drift50ppm/K
Response time<0.5s (0~90%) (TYP)
Insulation strength1500V AC/1min,2mA
Insulation resistanceAbove 100M Ω at 500VDC
Electromagnetic compatibilityCompliant with GB/T18268 (IEC61326-1)
WeightAbout 90g
Connected field equipmentTwo wire thermocouple
Input data
Input signal0~400ºC;0~1000ºC;0~1600ºC;
Excitation≥100KΩ
Output data
Output signal0/1~5V;0/4~20mA
Output impedanceCurrent type ≤ 680 Ω; Voltage type ≥ 330K Ω
Power supply
Supply voltage(Ue)24VDC±10%
Power protectionReverse protection of power supply
Power consumption<1W
Power supply modeIndependent power supply
Power connecting modeTerminal power supply
Overall dimension
Depth100mm
Height100mm
Width7.5mm
Housing
MaterialABSflame retardant
Degree of protectionIP20
Flammability ratingUL94/V0
ColourBlack
EMC data
Electrical fast transient/burst immunityCompliant with:IEC 61326-1;A-leve
Surge immunityCompliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunityCompliant with:IEC 61326-1;conform to basic requirements
Electrostatic discharge immunityCompliant with:IEC 61326-1;A-leve
Immunity to conducted disturbances, induced by radio-frequency fieldsCompliant with:IEC 61326-1;conform to basic requirements
Low frequency common mode conductionCompliant with:IEC 61326-1;conform to basic requirements
Operating conditions
Continuous operating temperature-20ºC~+60ºC
Storage temperature-40ºC~+80ºC
Relative humidity< 90% RH(no condensate)
Environmental requirementsThere should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances
Connection data
Conductor cross section solid range0.5~2.5mm²
Conductor cross section AWG min.12
Conductor cross section AWG max.24
Stripping length8mm
Screw threadM3
Connection methodScrew connection
Tightening torque min.0.5 Nm
Tightening torque max.0.6 Nm
Installation
Installation methodDIN35mm
Overall dimension