ISO 4-20mA
Electromagnetic
Digital Output
Injection
Plastic
0.2G
Hard-Switching
IP20
Ce/RoHS/FCC
Customized
4-20mA
4-20mA
Electromagnetic Isolation
3000VDC
SIP12pin
50Hz
-45~+85 Centigrade
3-4days
2 Years
DHL ,FedEx, etc
Paypal, T/T, Western Union
Black
Support
Nonlinearity<0.2%
PCB Module, DIN3 , DIN35 Rail-Mounted
SUNYUAN
SIP12pin
ISO9001: 2008, CE, ROHS
Shenzhen, Guangdong, China
8543709200
Product Description
Isolation Type 4-20mA Current Input Output Signal Converter
Characteristics:
Applications:
· Analog signal data acquisition and isolation
· Isolated 4-20mA signal transmission
· Industrial process signal isolation
· Ground-loop elimination
· No distortion in long distance signal transmission
· Instrument signal acquisition
· Electric supervision and medical application
· Isolated safe bar
· Biomedical measurements

Description:
ISO 4-20mA Loop Powered Isolator IC recieves 4-20mA/0-20mA signals and transmit them through a single chip. The ceramic hermetic hybrid package contains an electromagnetic coupled converter and current module. The very low input equivalent impendence allows an ultra-wide voltage input range, so that it is able to meet the requirements that no distortion in long-distance signal transmission under the circumstance without any external power. The internal ceramic PCB, resistance and new isolation technique allow the IC to withstand the 3KVDC insulated voltage and meets the industrial requirements like the extremely poor temperature, humidity and shaking conditions. These specifications make the ISO 4-20mA Current Loop Isolation Interface IC very easy to install in PCB.
Installation method as bellow:




Other prodcuts:




Other products:
Commonly used two-wire passive isolation amplifier, isolation transmitter IC, Sunyuan product technical information download:
1,4-20mA (0-20mA) Current Loop Isolator IC: ISOS 4-20mA
2,4-20mA two-wire passive I/V conversion isolation transmitter IC: ISO 4-20mA-O series
3,4-20mA isolation controller (active signal PLC current loop active load) IC: ISO 4-20mA-E
4,Two-wire passive sensor 4-20mA loop isolation distributor IC: ISO 4-20mA-F
5,Two-wire voltage signal power distribution isolation transmitter IC: ISO V-4-20mA
Commonly used active type (external auxiliary power supply required) isolation amplifier transmitter IC, product selection application data download:
1,ISO mV series: millivolt-level analog small signal dedicated isolation amplifier IC
2, ISO EM U(A)-P-O-T Series: Zero-point, gain-adjustable analog isolation amplifier isolation transmitter
3, ISO EM A(U)-P-O-S Series: Input Distribution Isolation Transmitter IC
4, ISO EM-U(A)-P-O-O Series: Analog Input Isolation Transmitter with 1 to 2 Output Low Cost Small Size IC mounted Package 5, ISO EM A-P-O Series: 0-±10V Bilateral DC (Voltage/Current) Signal Isolation Amplifier Isolation Transmitter IC
6, DIN3 ISOEM U-P-O(A-P-O) Series: Single DIN35 rail mounting packaging low cost small volume isolation transmitter
7,DIN 1X2 ISOEM U(A)-P-O Series: one input and two output DIN35 rail mounting packaging isolation transmitter
8,DIN 2X1 C-P-O Series: 2 input and 1 output analog average isolation transmitter
9,DIN 2X2 ISOEM U(A)-P-O Series: two in two out DIN35 rail mounting isolation transmitter
10,DIN 1X3 ISOEM U(A)-P-O Series:one in three out DIN35 Rail mounting isolation transmitter
11,DIN ISO AC Series: Passive two-wire AC to DC signal isolation transmitter
12,ISO EMH 4-20mA Series: High isolation barrier for track voltage monitoring
13,ISO F-P-O Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC
14,ISO U(A)-P-F Series: Analog Signal to Frequency Pulse Signal (V/F) Isolated Transmitter IC
15,ISO EM RMS-P-O Series: Analog True RMS (RMS) Signal Isolation Transmitter Isolation Amplifier
16.Large current output type high precision signal transmitter
Characteristics:
Item No. | ISO 4-20MA |
isolated voltage | 3000VDC |
Industrial temperature | -45~+85 º C |
High linearity | Nonlinearity<0.2% |
Small signal bandwidth | 50HZ |
Applications:
· Analog signal data acquisition and isolation
· Isolated 4-20mA signal transmission
· Industrial process signal isolation
· Ground-loop elimination
· No distortion in long distance signal transmission
· Instrument signal acquisition
· Electric supervision and medical application
· Isolated safe bar
· Biomedical measurements

Description:
ISO 4-20mA Loop Powered Isolator IC recieves 4-20mA/0-20mA signals and transmit them through a single chip. The ceramic hermetic hybrid package contains an electromagnetic coupled converter and current module. The very low input equivalent impendence allows an ultra-wide voltage input range, so that it is able to meet the requirements that no distortion in long-distance signal transmission under the circumstance without any external power. The internal ceramic PCB, resistance and new isolation technique allow the IC to withstand the 3KVDC insulated voltage and meets the industrial requirements like the extremely poor temperature, humidity and shaking conditions. These specifications make the ISO 4-20mA Current Loop Isolation Interface IC very easy to install in PCB.
Installation method as bellow:





Other prodcuts:

Features:
1. No external power supply required, two-wire signal loop
1. No external power supply required, two-wire signal loop
powered output mode.
2. Active 4-20mA signal acquisition, volt. (5-32V) extra-wide
range input.
3.High precision within 4-20mA measuring range (0.1, 0.2).
4-20mA signal transmission with high linearity(non-linearity
error <0.1%).
4. Active 4-20mA signal acquisition input, 3KV isolation
between input and output.
5. Active signal input, the output can control the active load
in current loop.
6. SIP 12Pin small size, UL94V-0standard fire-retardant
package.
7. Industrial operating temp. : - 45ºC ~ + 85ºC.

Features:
1. No external power supply required, two-wire signal loop powered output mode.
2. Active 4-20mA signal acquisition, volt. (5-32V) extra-wide range input.
3.High precision within 4-20mA measuring range (0.1, 0.2).
4.4-20mA signal transmission with high linearity(non-linearity error <0.1%).
5. Active 4-20mA signal acquisition input, 3KV isolation between input and output.
6. Active signal input, the output can control the active load in current loop.
7. SIP 12Pin small size, UL94V-0standard fire-retardant package.
8. Industrial operating temp. : - 45ºC ~ + 85ºC.
Applications of Two-wire 4-20mA Current Loop Transmitter/Conditioner:
1. Two-wire active load signal matching and controlling.
2.PLC, DCS site analog signal isolation and acquisition.
3. Ground wire current loop isolation and interference.
4. The matching between sensor signals and analog data input and output terminals.
5. Sensor 4-20mA signal isolated acquisition, conditioning and transmission.
6. Analog signal data isolated acquisition and long-distance transmission.
7. Electric meters and instruments, medical equipments.
1. No external power supply required, two-wire signal loop powered output mode.
2. Active 4-20mA signal acquisition, volt. (5-32V) extra-wide range input.
3.High precision within 4-20mA measuring range (0.1, 0.2).
4.4-20mA signal transmission with high linearity(non-linearity error <0.1%).
5. Active 4-20mA signal acquisition input, 3KV isolation between input and output.
6. Active signal input, the output can control the active load in current loop.
7. SIP 12Pin small size, UL94V-0standard fire-retardant package.
8. Industrial operating temp. : - 45ºC ~ + 85ºC.
Applications of Two-wire 4-20mA Current Loop Transmitter/Conditioner:
1. Two-wire active load signal matching and controlling.
2.PLC, DCS site analog signal isolation and acquisition.
3. Ground wire current loop isolation and interference.
4. The matching between sensor signals and analog data input and output terminals.
5. Sensor 4-20mA signal isolated acquisition, conditioning and transmission.
6. Analog signal data isolated acquisition and long-distance transmission.
7. Electric meters and instruments, medical equipments.

Features:
1. Low cost,small size,SIP 12 anti- fire UL94V-0 package
1. Low cost,small size,SIP 12 anti- fire UL94V-0 package
2. No external component,need not "ZERO"and "G.adj" adjustment.
3. Three-port (power/input/output) isolation:3000VDC
4. Assistant power:5VDC/12VDC/15VDC/24VDC
5. 0-75mV/0-2.5V/0-5V/0-10V/0-±100mV/0-±5V/0-±10V voltage signal
or 0-10mA/0-2mA/4-20mA/0-±10mA/0-±20mA current signal isolation and transfer
6. Industrial temperature range: -45~+85 ºC
7. In EMC(electromagnetism disturb) circumstance, shield measure required.

Features:
1. Low cost, small size. Directly soldered on the PCB board mounted.SIP 16 anti- fire UL94V-0 package
1. Low cost, small size. Directly soldered on the PCB board mounted.SIP 16 anti- fire UL94V-0 package
2. Easy to use, no zero adjustment except external gain adjustment.
3. Full range with high linearity. (Non-linearity <0.2%)
4. Power / signal input / two-way signal output,isolation 3000VDC, four-port isolated.
5. Auxiliary power supply: 5V, 12V, 15V, 24V.
6. SIP-16 meets UL94V-0 flame retardant package.
7. 0-75mV/0-5V/0-10V/0-±100mV/0-±10Vvoltage signal or 0-10mA/4-20mA/0-±20mA current signal isolation, amplifier and converter
8. Temperature range: -45~+85 ºC

Features:
1. Three-wire, four-wire or two-wire PT100/Cu50 thermal resistance signal input
2. Accuracy, Linearization error grade:0.2(Relative Temperature)
3. Built-in linear processing and long-term compensation circuit
4. Isolation Voltage: 3000VDC Three port: input/power/output
5. Auxiliary Power Supply:5V, 12V, 15V or 24VDC, etc
6. International standard signal output:4-20mA/0-5V/0-10V etc
7. Small size, low cost, easy use and high reliability
8. Standard DIP 24/SIP12 Pin, UL94V-0 package
9. Industrial temperature range: - 45ºC ~ + 85 ºC
10. Temperature signal isolation, acquisition and transfer
11. Industry site high-precision temperature measure
12 Terminal resistance signal isolation and temperature control
13. Ground interference suppression
14. Temperature sensor signal converter to standard signal
15. Oil temperature measure and Alarm
16. Signal remote without distortion transmission
17. Power monitoring, medical equipment, temperature control isolation barrier
1. Three-wire, four-wire or two-wire PT100/Cu50 thermal resistance signal input
2. Accuracy, Linearization error grade:0.2(Relative Temperature)
3. Built-in linear processing and long-term compensation circuit
4. Isolation Voltage: 3000VDC Three port: input/power/output
5. Auxiliary Power Supply:5V, 12V, 15V or 24VDC, etc
6. International standard signal output:4-20mA/0-5V/0-10V etc
7. Small size, low cost, easy use and high reliability
8. Standard DIP 24/SIP12 Pin, UL94V-0 package
9. Industrial temperature range: - 45ºC ~ + 85 ºC
10. Temperature signal isolation, acquisition and transfer
11. Industry site high-precision temperature measure
12 Terminal resistance signal isolation and temperature control
13. Ground interference suppression
14. Temperature sensor signal converter to standard signal
15. Oil temperature measure and Alarm
16. Signal remote without distortion transmission
17. Power monitoring, medical equipment, temperature control isolation barrier
Other products:
Commonly used two-wire passive isolation amplifier, isolation transmitter IC, Sunyuan product technical information download:
1,4-20mA (0-20mA) Current Loop Isolator IC: ISOS 4-20mA
2,4-20mA two-wire passive I/V conversion isolation transmitter IC: ISO 4-20mA-O series
3,4-20mA isolation controller (active signal PLC current loop active load) IC: ISO 4-20mA-E
4,Two-wire passive sensor 4-20mA loop isolation distributor IC: ISO 4-20mA-F
5,Two-wire voltage signal power distribution isolation transmitter IC: ISO V-4-20mA
Commonly used active type (external auxiliary power supply required) isolation amplifier transmitter IC, product selection application data download:
1,ISO mV series: millivolt-level analog small signal dedicated isolation amplifier IC
2, ISO EM U(A)-P-O-T Series: Zero-point, gain-adjustable analog isolation amplifier isolation transmitter
3, ISO EM A(U)-P-O-S Series: Input Distribution Isolation Transmitter IC
4, ISO EM-U(A)-P-O-O Series: Analog Input Isolation Transmitter with 1 to 2 Output Low Cost Small Size IC mounted Package 5, ISO EM A-P-O Series: 0-±10V Bilateral DC (Voltage/Current) Signal Isolation Amplifier Isolation Transmitter IC
6, DIN3 ISOEM U-P-O(A-P-O) Series: Single DIN35 rail mounting packaging low cost small volume isolation transmitter
7,DIN 1X2 ISOEM U(A)-P-O Series: one input and two output DIN35 rail mounting packaging isolation transmitter
8,DIN 2X1 C-P-O Series: 2 input and 1 output analog average isolation transmitter
9,DIN 2X2 ISOEM U(A)-P-O Series: two in two out DIN35 rail mounting isolation transmitter
10,DIN 1X3 ISOEM U(A)-P-O Series:one in three out DIN35 Rail mounting isolation transmitter
11,DIN ISO AC Series: Passive two-wire AC to DC signal isolation transmitter
12,ISO EMH 4-20mA Series: High isolation barrier for track voltage monitoring
13,ISO F-P-O Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC
14,ISO U(A)-P-F Series: Analog Signal to Frequency Pulse Signal (V/F) Isolated Transmitter IC
15,ISO EM RMS-P-O Series: Analog True RMS (RMS) Signal Isolation Transmitter Isolation Amplifier