Electromagnetic Relay
Household Appliances Relay, Smart Meter, EV Charger, Solar System,
1
Ac
1
High Power Relay
Enclosed Relay
Electromagnetic Type
Miniature
Electric Parameter Relay
High Power Latching Spdt Relay
60A, 250VAC
6~48VDC
Agsno2
Black
IVY
Cartons/Pallet
39*15.5*16.5mm
Zhejiang, China
8536411000
Product Description





Basic Data | Dimension(mm) | 38×30×16.5 | |
Weight ( g ) | ≈33g | ||
Contact Arrangement | 1A/1B | ||
Contact Material | AgSnO2 | ||
Ambient Temperature | -40~+70ºC | ||
Ambient Humidity | 45%~90%RH | ||
Vibration | 10~55Hz,1.5mm(DA) | ||
Specification Data | Nominal Voltage | 6~48VDC | |
Power Consumption | Single Coil:1.5W, Dual Coil:3W | ||
Max. Switching Voltage | 250VAC | ||
Max. Switching Current | 60A | ||
Max. Switching Power | 15000 VA | ||
Contact Resistance | <1.5 mΩ | ||
Insulation Resistance | 1000MΩ(DC 500V) | ||
Dielectric Creepage | 10mm | ||
Dielectric Strength | Across Open Contact | >1500VAC 1min | |
Coil to Contact | >4000VAC 1min | ||
Electrical Life | >10,000cycles | ||
Mechanical Life | >100,000cycles | ||
Picking-up & Release Time | <=20ms | ||
Pulse Duration | >=100ms | ||
Functional Shock Resistance | 10G | ||
Destructive Shock Resistance | 100G |




1.Suggestions of relay's input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
2.Suggestions of relay's output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.