MDS-2000CD
warranty
1 Year
Digital
Non Portable
Food Analysis, Medical Research, Biochemistry, Water
ISO9001, CE, FCC
MADSUR
Carton Packing
30mm*185mm
China
Product Description

Applications
|
|
|
|
|
Advanced Signal Output: Equipped with RS-485 (Modbus RTU) protocol for seamless integration with PLCs, DCS, industrial control computers, general controllers, or third-party devices like touch screens or recorders. |
Wide Application Range: Ideal for drinking water, groundwater, industrial water, and various water treatment applications. |
High Durability: Features IP68 protection for reliable operation in challenging environments, ensuring resistance to dust and water immersion. |
High Measurement Precision: Offers a range of 0~200 μS/cm with high accuracy and resolution for precise water quality monitoring. |
Automatic Temperature Compensation: Built-in Pt1000 temperature compensation ensures accurate readings across varying environmental conditions. |
Working Principle | Electric Generated Method | Temperature compensation accuracy | ±0.1ºC |
Measuring Range | (0-10,000/100,000) µS/cm | Protection Level | IP68 |
Resolution | 0.1 µS/cm | Interface | RS485, Modbus RTU |
Measurement Accuracy | ≤0.5% | Size specifications | D30mm, L185mm |
Electrode Constant | (0.1, 1, 10)cm-1 | Operating Temperature | (0-60)ºC |
Process Pressure | (0-3) bar | Material | ABS+316 Stainless steel |
Power Requirements | 12-24V DC | Warranty Period | 1 year |
Cable | 5m or customizable |