SNG
Aerosol
Fire Suppression System
Class A Fires
100g, 200g,300g,500g,
CE, UL
Aerosol Fire Suppression
9m
12 Years
Aerosol
Aerosol
Steel
SYNERGY
by Cartons Suit for Sea Delivery
EN3, CE, ISO, DOT
China
84241000
Product Description
Aerosol Fire Suppression can be widely used in energy storage, wind power, integrated pipe corridors, distribution rooms and other scenarios




Model | QRR0.1G-U02 | QRR0.2G-U02 | JAD300-U01 | QRR0.5G-U02 | QRR0.5G-U03 | QRR0.75G-U03 | QRR1G-U03 | QRR1G-U03 |
Mass of Compound | 100g | 200g | 300g | 500g | 500g | 200g | 1kg | 3kg |
Operating Temperature Range | -40°C~+54°C | -40°C~+54°C | -40°C~+54°C | -40°C~+54°C | -40°C~+54°C | -40°C~+54°C | -40°C~+54°C | -40°C~+54°C |
Actuation Method | Electrical | Electrical | Electrical | Electrical | Electrical | Electrical | Electrical | Electrical |
Discharge Time | 7.20s (±5s) | 6.40s (±5s) | 15s (±5s) | 6.70s (±5s) | 16.00s (±5s) | 14.70s (±5s) | 11.10s (±5s) | 13.10s (±5s) |
Oxidant Name and Content | Potassium nitrate 59% ~ 69% | |||||||
Nozzle 200°C, 75°C Thermal Clearance | 0.2m, 0.9m | 0.2m, 1.0m | 0.7m, 1.3m | 0.5m, 1.5m | 0.6m, 1.5m | 1.5m, 2.0m | 0.7m, 1.6m | 2m, 3m |
Minimum Design Application Density | Class A: 91g/m^3 Class B: 78g/m^3 Class C: 78g/m^3 Fuel combination: 91g/m^3 | Class A: 91g/m^3 Class B: 78g/m^3 Class C: 78g/m^3 Fuel combination: 91g/m^3 | Class A: 105.3g/m^3 Class B: 78g/m^3 Class C: 105.3g/m^3 Fuel combination: 105.3g/m^3 | Class A: 97.5g/m^3 Class B: 78g/m^3 Class C: 78g/m^3 Fuel combination: 97.5g/m^3 | Class A: 97.5g/m^3 Class B: 78g/m^3 Class C: 78g/m^3 Fuel combination: 97.5g/m^3 | Class A: 97.5g/m^3 Class B: 78g/m^3 Class C: 78g/m^3 Fuel combination: 97.5g/m^3 | Class A: 91g/m^3 Class B: 78g/m^3 Class C: 78g/m^3 Fuel combination: 91g/m^3 | Class A: 117g/m^3 Class B: 78g/m^3 Class C: 78g/m^3 Fuel combination: 117g/m^3 |
Net Weight | 890g (±50g) | 1470g (±70g) | 2320g (±70g) | 4570g (±150g) | 3200g (±100g) | 4010g (±245g) | 7810g (±150g) | 18680g (±1120g) |
Standard Sizes | f57mm(±0.2mm) x 180mm(±3mm) | f76mm(±0.2mm) x 192mm(±3mm) | f76mm x 192mm | f159mm(±0.2mm) x 163mm(±3mm) | f76mm(±0.2mm) x 425mm(±3mm) | f157.4mm x 88.4mm x 274.5mm(±3mm) | f159mm(±0.2mm) x 314mm(±3mm) | 229mm x 229mm x 373mm(±3mm) |
Maximum Protection Space | 1.67 m3 | 3.34 m^3 | 5 m^3 | 8.34 m^3 | 8.34 m^3 | 12.5 m^3 | 16.67 m^3 | 50 m^3 |
Device Finished Resistor | 1.1±0.2 | 1.1±0.2 | 1.1±0.2 | 1.1±0.2 | 1.1±0.2 | 1.1±0.2 | 1.1±0.2 | 1.1±0.2 |
Electric Intiator Rated Current | 2A/5ms | 2A/5ms | 2A/5ms | 2A/5ms | 2A/5ms | 2A/5ms | 2A/5ms | 2A/5ms |
Reference Picture | ||||||||
Feedback | Normally open and closed (non-recoverable) | |||||||
Useful Time | 15 years | |||||||
Certificate and Standard | UL, ULC, BSI, CSIRO |